TRIO-PS-2G/230AC-400DC/48DC/5 - Power supply unit


Input data | AC operation Supply system configuration: Star network (TN, TT, IT (PE)) Nominal input voltage range: 220 VÃAC ... 240 VÃAC Input voltage range: 220 VÃAC ... 240 VÃAC -15Ã%Ã...Ã+10Ã% Switch-on voltage: typ. 70 VÃAC Shut-down voltage: typ. 50 VÃAC Electric strength, max.: ââ°¤ 300 VÃAC 15 s Typical national grid voltage: 230 VÃAC Voltage type of supply voltage: AC Inrush current integral (I2t): < 0.3 A2s Inrush current limitation: < 13.5 A (after 1Ãms) AC frequency range: 50 Hz ... 60 Hz ñ10Ã% Mains buffering time: > 20 ms (190ÃVÃAC) > 20 ms (230 V AC) Current consumption: 1.3 A (230 V AC) Nominal power consumption: 285.7 VA Power factor (cos phi): 0.91 Input fuse: 3.15 A (internal (device protection)) Recommended breaker for input protection: 4 A ... 16 A (Characteristic B, C, Z) Discharge current to PE: < 3.5 mA < 1.7 mA (264ÃVÃAC, 60ÃHz) POWER factor: > 0.9 (230 V AC) DC operation Nominal input voltage range: 220 VÃDC ... 400 VÃDC Input voltage range: 220 VÃDC ... 400 VÃDC -15Ã%Ã...Ã+5Ã% Derating: < 99 VÃDC (2 %/V) Switch-on voltage: typ. 95 VÃDC Shut-down voltage: typ. 50 VÃDC Electric strength, max.: ââ°¤ 420 VÃDC Voltage type of supply voltage: DC Mains buffering time: > 20 ms (185ÃVÃDC) > 25 ms (400ÃVÃDC) Current consumption: 1.3 A (220 VÃDC) 0.7 A (400ÃVÃDC) |
Output data | Efficiency: typ. 92.5 % (230 V AC) typ. 94 % (400ÃVÃDC) Output characteristic: U/I with dynamic load reserve Nominal output voltage: 48.5 VÃDC ñ1Ã% Nominal output current (IN): 5 A Dynamic Boost (IDyn.Boost): 7.5 A (5 s) Derating: > 60°C ... 70°C (2.5%/K) POWER factor: > 0.9 (120ÃVÃAC) > 0.9 (230 V AC) Feedback voltage resistance: ââ°¤ 60 VÃDC Protection against overvoltage at the output (OVP): ââ°¤ 58 VÃDC Control deviation: < 1.5 % (change in load, static 10 % ... 90 %) < 4 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ñ10 %) Residual ripple: < 20 mVPP (with nominal values) Short-circuit-proof: yes No-load proof: yes Output power: 240 W 360 W Peak switching voltages nominal load: < 15 mVPP Maximum no-load power dissipation: typ. 4 W (230 V AC) typ. 4 W (400ÃVÃDC) Power loss nominal load max.: typ. 20 W (230 V AC) typ. 15 W (400ÃVÃDC) Short-circuit current: < 7 AÃDC (Permanent) Rise time: 20 ms (UOUT (10 % ... 90 %)) Connection in parallel: yes, for redundancy and increased capacity Signal: DC OK Continuous load current: 100 mA Signal relay 13/14 Default: closed Digital: 30 VÃAC 30 VÃDC 100 mA |
Connection data | Input Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 4 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.25 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 1.5 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.25 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 12 Output Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 4 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.25 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 1.5 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.25 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 12 Signal Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 0.75 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 1.5 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.2 mm² Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 0.75 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.2 mm² Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 1 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 18 |
Signaling | Types of signaling: Floating signal contact Signal output: LED status indicator Signalization designation: DC OK Status display: LED Color: green DC OK: UOUT > 0.7 x UN (UN = 48ÃVÃDC) |
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 3.5 kV AC (type test) 1.5 kV AC (routine test) |
Product properties | Product type: Power supply Product family: TRIO POWER MTBF (IEC 61709, SN 29500): > 2220000 h (25ðC) > 1280000 h (40ðC) > 560000 h (60ðC) > 2220000 h (25ðC) > 1280000 h (40ðC) > 560000 h (60ðC) Insulation characteristics Protection class: I (in closed control cabinet) Degree of pollution: 2 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9240672528a5f64d9507d9acab7c1ea2/-S204x204-FJPG Width: 42 mm Height: 130 mm Depth: 160 mm Installation dimensions Installation distance right/left: 0 mm / 0 mm Installation distance top/bottom: 50 mm / 50 mm |
Mounting | Mounting type: DIN rail mounting Assembly instructions: alignable: horizontally 0 mm (ââ°¤ 40°C) 10 mm (ââ°¤ 70°C), vertically 50 mm Mounting position: horizontal DIN rail NS 35, EN 60715 With protective coating: No |
Material specifications | Flammability rating according to ULÃ94 (housing / terminal blocks): V0 Housing material: Metal Type of housing: Aluminum (AlMg3) Hood version: Polycarbonate |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (>60°CÃderating:Ã1.6%/K) Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (start-up type tested): -40°C Maximum altitude: ââ°¤ 2000 m Climatic class: 3K3 (ENÃ60721) Max. permissible relative humidity (operation): ââ°¤ 95 % (at 25°C, non-condensing) Shock: 20Ãm/s² (2g), 11Ãms, ñÃ100 Schocks (DINÃENÃ50125-3, DINÃENÃ60068-2-27) Vibration (operation): 5ÃHzÃ...Ã2ÃkHz, 2.3Ãm/s² (0.23g) (RMS) 5Ãh (DIN EN 50125-3, DIN EN 60068-2-64) |
Standards and regulations | Rail applications: ENÃ50121-3-2 ENÃ50121-4 ENÃ50124-1 ENÃ50125-3 IEC 62236-3-2 IEC 62236-4 IEC 62236-5 Standard ââ¬Ã¢ Limitation of mains harmonic currents: ENÃ61000-3-2 Standard - Electrical safety: ENÃ61010-1 VDEÃ0805 (SELV) Standard ââ¬Ã¢ Safety extra-low voltage: IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Standard - Safe isolation: IEC 61010-2-201 IEC 61558-2-16 Standard - Safety of power supply units up to 1100 V (insulation distances): DINÃENÃ61558-2-16 Overvoltage category EN 62477-1: IIÃ(ââ°¤Ã2000Ãm) IIIÃ(ââ°¤Ã2000Ãm) |
Approvals | UL approvals: ULÃ61010-1 UL 61010-2-201 Conformity/Approvals SIL in accordance with IEC 61508: 0 |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC Interference emission: Interference emission in accordance with ENÃ61000-6-3 (residential and commercial) and ENÃ61000-6-4 (industrial) EMC requirements for noise immunity: ENÃ61000-6-1 ENÃ61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Conducted noise emission: ENÃ55016 ENÃ61000-6-3 (Class B) Noise emission: EN 55011 (EN 55022) ENÃ55016 ENÃ61000-6-3 (Class B) Harmonic currents Standards/regulations: ENÃ61000-3-2 Frequency range: ClassÃA Flicker Standards/regulations: ENÃ61000-3-3 Frequency range: 0 kHz ... 2 kHz Electrostatic discharge Standards/regulations: ENÃ61000-4-2 Electrostatic dischargeââ¬Ã¢¹ Contact discharge: 6 kV (Test Level 4) Discharge in air: 8 kV (Test Level 4) Comments: Criterion A Electromagnetic HF field Standards/regulations: ENÃ61000-4-3 Electromagnetic HF fieldââ¬Ã¢¹ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 2.7 GHz Test field strength: 20 V/m (Test Level 3) 10 V/m (Test Level X) 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: ENÃ61000-4-4 Fast transients (burst)ââ¬Ã¢¹ Input: 4 kV (Test Level 4 - asymmetrical) Output: 2 kV (Test Level 3 - asymmetrical) Signal: 2 kV (Test Level 4 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: ENÃ61000-4-5 Input: 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal: 1 kV (Test Level 2 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: ENÃ61000-4-6 Conducted interferenceââ¬Ã¢¹ I/O/S: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Voltage dips Standards/regulations: ENÃ61000-4-11 Voltage: 230 VÃAC Frequency: 50 Hz Voltage dip: 70 % 40 % 0 % Number of periods: 25 periods 10 periods 1 period Additional text: Test Level 2 Comments: Criterion A Emitted interference Standards/regulations: ENÃ61000-6-3 Radio interference voltage in acc. with EN 55011: ENÃ55011 (ENÃ55022) ClassÃB, area of application: Industry and residential Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |