| Features | | Measurement principle | HDDM+ |  | Application | Outdoor |  | Light source | Infrared (850 nm) |  | Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) |  | | Aperture angle |  |  | Horizontal | 270° | 
 |  | Scanning frequency | 15 Hz |  | Angular resolution | 1° |  | Working range | 0.05 m ... 10 m |  | | Scanning range |  |  | At 10% remission factor | 8 m | 
 | 
 | 
| Mechanics/electronics | | Connection type | 1 x “Ethernet” connection, 4-pin M12 female connector 1 x connection “Power”, 12-pin, M12 male connector 1 x Micro USB female connector, type B |  | Supply voltage | 9 V DC ... 28 V DC |  | Power consumption | Typ. 4 W, 16 W with 4 max. loaded digital outputs |  | Output current | ≤ 100 mA |  | Housing color | Gray (RAL 7032) |  | Enclosure rating | IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013) |  | Protection class | III (IEC 61140:2016-1) |  | Weight | 250 g, without connecting cables |  | Dimensions (L x W x H) | 60 mm x 60 mm x 86 mm |  | MTBF | > 100 years | 
 | 
| Safety-related parameters |  | 
| Performance | | Response time | 1 scan, typ. 67 ms 2 scans, ≤ 134 ms  |  | Detectable object shape | Almost any |  | Systematic error | ± 60 mm |  | Statistical error | < 20 mm |  | Integrated application | Field evaluation with flexible fields |  | Number of field sets | 16 field triples (48 fields, contour as reference; 1 triple (3 flexible fields) can be configured directly at the scanner) |  | Simultaneous evaluation cases | 1 (3 fields) 2 (2 fields for detection and 1 field for contour as reference) | 
 | 
| Interfaces | | | Ethernet | ✔ , TCP/IP |  | Function | Service interface, parameterization | 
 |  | Digital inputs | 4 |  | Digital outputs | 3 (PNP, additional 1 x “Device Ready”) |  | Delay time | 67 ms ... 30,000 ms (configurable) |  | Dwell time | 67 ms ... 600,052 ms (configurable) |  | Optical indicators | 2 LEDs (ON, switching status) | 
 | 
| Ambient data | | Object remission | 4 % ... 1,000 % (reflectors) |  | | Electromagnetic compatibility (EMC) |  |  | Emitted radiation | Residential area (EN 61000-6-3:2007+AMD:A1:2011) |  | Electromagnetic immunity | Industrial environment (EN 61000-6-2:2005) | 
 |  | | Vibration resistance |  |  | Sine resonance scan | 10 Hz ... 1,000 Hz |  | Sine test | 10 Hz ... 500 Hz, 5 g, 10 frequency cycles |  | Noise test | 10 Hz ... 250 Hz, 4.24 g RMS, 5 h | 
 |  | Shock resistance | 50 g, 11 ms, ± 3 single shocks/axis  25 g, 6 ms, ± 1,000 continuous shocks/axis  50 g, 3 ms, ± 5,000 continuous shocks/axis  |  | Ambient operating temperature | –25 °C ... +50 °C |  | Storage temperature | –40 °C ... +75 °C |  | Switch-on temperature | –10 °C ... +50 °C |  | Temperature change | –25 °C ... +50 °C, 10 cycles |  | Damp heat | +25 °C ... +55 °C, 95 % RH, 6 cycles |  | | Permissible relative humidity |  |  | Operation | < 80 %, Non-condensing (EN 60068-2-30:2005) |  | Storage | ≤ 90 %, Non-condensing (EN 60068-2-30:2005) | 
 |  | Ambient light immunity | 80,000 lx | 
 | 
| General notes | | Note on use | The sensor does not constitute a safety component as defined by relevant legislation on machine safety. | 
 | 
| Classifications | | ECLASS 5.0 | 27270990 |  | ECLASS 5.1.4 | 27270990 |  | ECLASS 6.0 | 27270913 |  | ECLASS 6.2 | 27270913 |  | ECLASS 7.0 | 27270913 |  | ECLASS 8.0 | 27270913 |  | ECLASS 8.1 | 27270913 |  | ECLASS 9.0 | 27270913 |  | ECLASS 10.0 | 27270913 |  | ECLASS 11.0 | 27270913 |  | ECLASS 12.0 | 27270913 |  | ETIM 5.0 | EC002550 |  | ETIM 6.0 | EC002550 |  | ETIM 7.0 | EC002550 |  | ETIM 8.0 | EC002550 |  | UNSPSC 16.0901 | 41111615 | 
 |