SICK 1061770
SICKNot available

KTM-WP117A1P

Contrast sensors: KTM
Product Code: 1061770
Partner cod.: 1061770
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Features
Dimensions (W x H x D)12 mm x 31.5 mm x 21 mm
Sensing distance≤ 12.5 mm
Sensing distance tolerance± 3 mm
Housing designSmall
Light sourceLED, RGB 
Wave length470 nm, 525 nm, 625 nm
Light emissionLong side of housing
Light spot size1.6 mm x 9.5 mm
Light spot directionVertical 
Receiving filtersNone
AdjustmentCable, IO-Link, Teach-in button
Teach-in mode2-point teach-in static/dynamic + proximity to mark
Mechanics/electronics
Supply voltage12 V DC ... 24 V DC 
Ripple≤ 5 Vpp 
Current consumption< 50 mA 
Switching frequency15 kHz 
Response time32 µs 
Jitter15 µs
Switching outputPNP
Switching output (voltage)PNP: HIGH = UV ≤ 2 V / LOW approx. 0 V
Switching modeLight/dark switching
Output current Imax.50 mA 
Retention time (ET)28 ms, non-volatile memory
Time delaySwitch-off delay, 520 ms (via IO-Link)
Connection typeMale connector M8, 4-pin
Protection classIII
Circuit protection

UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure ratingIP67
Weight20 g
Housing materialPlastic, ABS
Optics materialPlastic, PMMA
Indication

LED indicator green: power on

LED indicator, yellow: Status switching output Q

Communication interface
IO-Link✔ , V1.1
Data transmission rate38,4 kbit/s (COM2)
Cycle time2.3 ms
Process data length16 Bit
Process data structure A

Bit 0 ... 2 = Emission Color

Bit 3 … 12 = Measurment Value RGB

Bit 13 … 15 = empty

Process data structure B

Bit 0 = switching signal QL1

Bit 1 … 10 = Measurment Value Emission Color

Bit 11 ... 15 = empty

Process data structure C

Bit 0 = switching signal QL1

Bit 1 = Quality of Run Alarm

Bit 2 = Teach successful

Bit 3 = Teach busy

Bit 4 ... 15 = empty

Digital outputQ1, Q2
Number2
Ambient data
Ambient operating temperature–10 °C ... +55 °C
Ambient temperature, storage–20 °C ... +75 °C
Shock loadAccording to IEC 60068
UL File No.NRKH.E348498 & NRKH7.E348498
Classifications
ECLASS 5.027270906
ECLASS 5.1.427270906
ECLASS 6.027270906
ECLASS 6.227270906
ECLASS 7.027270906
ECLASS 8.027270906
ECLASS 8.127270906
ECLASS 9.027270906
ECLASS 10.027270906
ECLASS 11.027270906
ECLASS 12.027270906
ETIM 5.0EC001820
ETIM 6.0EC001820
ETIM 7.0EC001820
ETIM 8.0EC001820
UNSPSC 16.090139121528
Connection/Pin assignment
Connection typeMale connector M8, 4-pin
Pin assignment
BN 1+ (L+)
WH 2Q
BU 3- (M)
BK 4Q/C