Features Support up to 31 I/O modules Offer Integrated Motion on EtherNet/IP up to 32 axes Ideal for small to mid-size applications that require low axis motion and I/O point counts Offer enhanced security features which include digitally-signed controller firmware, controller-based change detection, and logging and role-based access control to routines and Add-On Instructions Provide faster safety reaction time Enable high-speed I/O, motion control, and Device Level Ring/Linear Topologies Include dual configurable ports that supports Dual IP address Support up to 31 I/O modules per controller or adapter Support up to 31 Bulletin 5069 Compact I/O⢠modules Provide distributed I/O to the Compact GuardLogix 5380 and GuardLogix 5580, which is accessible via a 5069-AEN2TR or 5069-AENTR over an EtherNet/IP Provide field-side power to field-side devices that are connected to some Compact 5000 I/O modules Offer controller functions optimized for maximum system performance Provide enhanced diagnostics and troubleshooting Provide improved status indicators to monitor and troubleshoot systems Provide a local safety connectivity to the Compact GuardLogix 5380 Provide separate system power for better isolation and built-in power input with field power to I/O modules Function as local I/O in a CompactLogix⢠5380 or CompactLogix 5480 control system or as distributed I/O accessible via a 5069-AEN2TR or 5069-AENTR over an EtherNet/IP network for CompactLogix 5380 and ControlLogix® 5580 controllers Support 1 Gb embedded switch technology for Linear and Device Level Ring topologies Provide enhanced diagnostics information Provide high-speed backplane communications for faster transfer rates Rated up to SIL3/PLe Offer a 1 gigabit (Gb) embedded Ethernet port that enables high-speed communications, I/O, and motion control Support distributed I/O modules via an EtherNet/IP network for CompactLogix 5380 and ControlLogix 5580 controllers Use the slim 5069-AENTR for small space requirements Are available in high-speed counter, digital input, digital output, analog input, analog output, AC input, AC output, isolated and non-isolated relay output, address reserve modules, and field potential distributor
Technical Specs
Specifications Note:The Controllers and 5069-AEN2TR require selection of Terminal Kits 5069-RTB64-SCREW or 5069-RTB64-SPRING. Please remember to update the quantity to match the number of Controller/Communication option selected. Product Selection Category:Controllers Controller Controller Capacity:3 MB I/O Modules (max):31 Ethernet/IP Nodes supported (max):60 Integrated Motion:16 Catalog Number Catalog Number:Controller, CompactLogix 5380, 3 MB User Memory, 31 I/Os, 16 axis, 60 EtherNet/IP Devices Note Note:The 5380 controllers did not come with the removable terminals. It is necessary to purchase the 5069-RTB64-SCREW or 5069-RTB64-SPRING terminal kits separately to use the 5380 controllers
To provide the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as your browsing behavior or unique IDs on this site. Not consenting or withdrawing consent may adversely affect some features and functions.
Functional
Always active
Technical storage or access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network .
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistics
Technical storage or access that is used solely for statistical purposes.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
Technical storage or access is necessary to create profiles of users to send advertising, or to track the user across a website or across different websites for similar marketing purposes.
To provide the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as your browsing behavior or unique IDs on this site. Not consenting or withdrawing consent may adversely affect some features and functions.
Functional
Always active
Technical storage or access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network .
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistics
Technical storage or access that is used solely for statistical purposes.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
Technical storage or access is necessary to create profiles of users to send advertising, or to track the user across a website or across different websites for similar marketing purposes.