Industrial Automation
Compact 5000 EtherNet/IP Adapter


Number of HW-interfaces industrial Ethernet | 1 |
With optical interface | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for other bus systems | No |
Redundancy | No |
IO link master | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | Yes |
Type of data transmission | Module rack extension |
Thermal dissipation, max | 29 BTU/h |
Power dissipation, max | 8.5 W |
Enclosure type rating | None (open-style) |
Module keying | Electronic keying via programming software |
RTB torque | 0.5...0.6 Nm (4.4...5.3 lb.in), (5069-RTB5-SCREW RTB only) |
Wiring category | 2 - on signal ports, 1 - on power ports, 2 - on Ethernet ports |
Insulation stripping length | 5069-RTB5-SPRING connections: 10 mm (0.39 in.), 5069-RTB5-SCREW connections: 10 mm (0.39 in.) |
Wire size | 0.25...2.5 mm2 (22...14 AWG) solid or stranded copper wire rated at 105 ðC (221 ðF), or greater, 1.2 mm (3/64 in.), insulation m, single wire connection only, Grounding: 2.5 mm2 (14 AWG) solid or stranded copper wire rated at 105 ðC (221 ðF), or greater, |
Isolation voltage | 250V (continuous), basic insulation type, SA, and MOD power to backplane, 250V (continuous), basic insulation type, SA to MOD power, 250V (continuous), basic insulation type, Ethernet to backplane, type tested at 1500V AC for 60 s, 250V (continuous), doub |
Supporting protocol for LON | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for SUCONET | No |
With potential separation | No |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
ATEX temp code | T4 |
RTB keying | None |
Width | 56 mm |
Height | 138 mm |
Depth | 105 mm |
Surrounding air temperature, max | 60 ðC |
Emissions | CISPR 11/22, Class A |
Vibration | 5 G @ 10...500 Hz |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ñ3kV @ 5 kHz on power ports, ñ3kV @ 5 kHz on Ethernet ports |
Relative humidity | 5...95% noncondensing |
Shock | Operating: 30 G, Non operating: 50 G |
Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz on power and Ethernet ports |
Surge transient immunity | ñ1kV line-line (DM) and ñ2kV line-earth (CM) on power ports, ñ2kV line-earth (CM) on Ethernet ports |
Operating temperature | 0 ðC |
Radiated RF immunity | 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
Nonoperating temperature | -40 ðC |
North American temperature code | T4 |
IECEx temp code | T4 |
MOD Power inrush | 1750 mA for 70 ms |
MOD power | 220 mA @ 18...32V DC |
SA power | 5 mA @ 0...32V DC, 2 mA @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum |
MOD power passthrough, max | 9.78 A @ 18...32V DC, Maximum level of MOD Power current that the adapter can pass through to the next module in the system |
SA power passthrough, max | 9.95 A @ 0...32V DC, 9.975 A @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum, Maximum level of SA power current that the adapter can pass through to the next module in the system |
Recommended external overcurrent protection | MOD power: 10...12A @ 22.5...43.2 A2t, fast acting, SA power: 20 A @ 250V AC |