Industrial Automation



| Number of outputs, safety related, undelayed, with contact | 0 |
| Number of outputs, safety related, delayed, with contact | 0 |
| Number of outputs, signalling function, undelayed, with contact | 0 |
| Number of outputs, safety related, undelayed, semiconductors | 10 |
| Number of outputs, safety related, delayed, semiconductors | 10 |
| Number of outputs, signalling function, undelayed, semiconductors | 10 |
| Number of outputs, signalling function, delayed, semiconductors | 10 |
| With start input | Yes |
| With muting function | Yes |
| Voltage type for actuating | DC |
| Rated control supply voltage at DC | 24 V |
| Model | Basic device |
| Type of electric connection | Screw connection |
| Evaluation inputs | Other |
| Power consumption | 5.28 W |
| Continuous output current | 0.5 A @ terminals 12...19 |
| Configurable logic | List function blocks like, two hand control |
| Wire size | 0.2...2.5 mmò (24...14 AWG) solid/stranded copper wire @ 90 ðC (194 ðF) insulation maximum |
| Number of outputs, signalling function, delayed, with contact | 0 |
| With feedback circuit | Yes |
| Suitable for monitoring of magnetic switches | Yes |
| Suitable for monitoring of proximity switches | Yes |
| Suitable for monitoring of emergency-stop circuits | Yes |
| Suitable for monitoring of optoelectronic protection equipment | Yes |
| Suitable for monitoring of position switches | Yes |
| Suitable for monitoring of tactile sensors | Yes |
| Suitable for monitoring of valves | Yes |
| Surge output current | 1 A |
| Surge output current duration | 5 ms |
| Aggregate current of outputs per device, max | 3 A |
| Other output | SWS output |
| Operating voltage | 20.4 V |
| SIL according to IEC 61508 | 3 |
| With approval according to UL | Yes |
| Stop category according to IEC 60204 | 2 |
| Performance level according to EN ISO 13849-1 | Level e |
| Type of safety according to IEC 61496-1 | 4 |
| With approval for TUV | Yes |
| With detachable clamps | No |
| Rated control supply voltage at AC 50 Hz | 0 V |
| Rated control supply voltage at AC 60 Hz | 0 V |
| Enclosure type rating | IP20 |
| Vibration | 10...55 Hz, 0.35 mm (0.014 inch) |
| Shock | Shock proof, operating: 10 G (0.35 oz), 16 ms |
| Rail mounting possible | Yes |
| Safety integrity level claim limit | 3 |
| Mode of operation | High demand mode |
| Category | up to 4 |
| PFD | 1.76E-03 (whole safety function) |
| Hardware fault tolerance | HFT = 1 (two channel system) |
| PFH | 1.00E-08 |
| Safe failure fraction | 90 % |
| Safety related subsystems | Type B (use of programmable/complex components) |
| Operating temperature | -5 ðC |
| Emissions | Group 1, Class A |
| Relative humidity | 90% |
| ESD immunity | 6 kV contact discharges, 8 kV air discharges |
| EFT/B immunity | On ethernet port: ñ1 kV @ 5 kHz |
| Surge transient immunity | On ethernet port: ñ1 kV line-earth(CM) |
| Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2700 MHz 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz |
| Storage temperature | -40 ðC |
| Conducted RF immunity | 10V RMS with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Height | 90 mm |
| Width | 100 mm |
| Depth | 80 mm |
| Performance level | up to e |
| Evaluation input | SWS input |
Description other products