Industrial Automation


| Suitable for safety functions | No |
| Digital inputs configurable | No |
| Digital outputs configurable | No |
| Voltage type of supply voltage | DC |
| Type of voltage (input voltage) | DC |
| Type of digital output | Relay |
| Type of electric connection | Screw connection |
| Bounce time, mean | 1.2 üs |
| Total backplane power | 2.9 W |
| Thermal dissipation | 10.57 BTU/h |
| Current draw | 100 mA @ 5.1V, 100 mA @ 24V |
| Expected contact life | 300 kHz, resistive, 100 kHz, inductive |
| Module keying | Electronic, software configurable |
| Outputs | 8 N.O., 8 N.C. individually isolated (two points per group) |
| Scheduled outputs | Synchronization within 16.7 s max, reference to the coordinated system time |
| Power dissipation, max | 3.1 W @ 60 ðC (140 ðF) |
| Contact current rating | 1 A @ 5...30V DC, 0.5 A @ 48V DC, 0.22 A @ 125V DC, 1.5 A @ 120V AC, 50/60 Hz, 0.75 A @ 240V AC, 50/60 Hz |
| Isolation voltage | 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output |
| Wire category | Wire category: 1 |
| Fusing | Not protected. A fused IFM is recommended to help protect outputs |
| Redundancy | No |
| Short-circuit protection, outputs available | No |
| Pilot duty | C300, R150 |
| Initial contact resistance, max | 100 mé @ 6V, 1 A |
| Switching frequency, max | 1 operation/3 s (0.3 Hz at rated load) |
| States in fault mode per point | Hold last state, On or Off (Off is default) |
| States in program mode per point | Hold last state, On or Off (Off is default) |
| Slot width | 1 |
| RTB keying | User-defined mechanical |
| Shock | Operating: 30 G, Non operating: 50 G |
| Vibration | 2 G @ 10...500 Hz |
| Surrounding air temperature, max | 60 ðC |
| North American temperature code | T4A |
| Emissions | IEC 61000-6-4 |
| ESD immunity | 6 kV contact discharges, 8 kV air discharges |
| Relative humidity | 5...95% noncondensing |
| Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| EFT/B immunity | ñ4 kV at 5 kHz on signal ports |
| Operating temperature | 0 to 60 ðC |
| Surge transient immunity | ñ1 kV line-line (DM) and ñ2 kV line-earth (CM) on signal ports |
| Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
| Nonoperating temperature | -40 ðC |
| Oscillatory surge withstand | IEEE C37.90.1: 3kV |
| Off-state leakage current per point, max | 0 mA |
| Load current per point, min | 10 mA |
| Output delay time | OFF to ON: 13 ms maximum, ON to OFF: 13 ms maximum |
| Operating voltage | 5...125V DC, 10...240V AC |
| Enclosure type | None (open-style) |