Motor Protection Circuit Breaker, A Frame, 0.40-0.63 A, Trip Class 10A, Standard Breaking Capacity, Standard Magnetic Trip (Fixed at 12.5 x le)








| With integrated under voltage release | No | 
| Rated operating voltage | 0 A | 
| Type of control element | Turn button | 
| Type of electrical connection of main circuit | Screw connection | 
| Rated impulse withstand voltage (Uimp) | 6 kV | 
| Magnetic trip current | 7.9 A | 
| Short circuit current for group motor, max | 30 kA @ 480V | 
| Motor current adjustment range | 0.40...0.63 A | 
| Short circuit current Icu, max | 100 kA @ 400V | 
| Rated operational current (Ie) | 0.63 A | 
| Ultimate short circuit breaking capacity (Icu) per IEC | 100 kA @ 690V AC | 
| Rated service short circuit breaking capacity (Ics) per IEC | 50 kA @ 400V AC | 
| Insulation voltage (Ui) | Rated 690V | 
| Hp rating, max | 0.33 Hp @ 575V, 3-phase | 
| KW rating, max | AC-3: 0.25 kW @ 690V, 3-phase | 
| Short circuit current rating | Type 1 coordination: 5 kA @ 600V AC | 
| Branch circuit protection per NEC/CEC, max | UL 60947 manual motor controller: 175 A | 
| Trip class | 10 A | 
| Fuse or circuit breaker size per NEC, max | UL 60947-4-1 manual motor controller: 175 A | 
| Short circuit current, max | Type 2 coordination, IEC 60947-4-1: 50 kA @ 400V | 
| Fuse or circuit breaker per NEC, max | UL 60947-4-1 manual motor controller: 175 A | 
| Short circuit current for group motor installation, max | UL 60947 manual motor controller: 5 kA @ 600V | 
| Short circuit current for motor disconnect, max | UL 60947 manual motor controller: 5 kA @ 600V | 
| Number of poles | 3 | 
| With thermal protection | Yes | 
| Phase failure sensitive | Yes | 
| Max current Ie | 32 A | 
| Maximum operating voltage (UL) | 600 V | 
| Disconnect function per IEC/EN 60947-2 | Yes | 
| Rated operating voltage (Ue) | 690V AC | 
| Rated frequency | 50/60 Hz | 
| Number of operations | Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1...16 A), 50000 cycles (20...32 A) | 
| Power loss | 5.1 W @ 0.16...1.6 rated operating current, 5.4 @ 2.5...6.3 rated operating current, 7.2 @ 10...12 rated operating current, 8.4 @ 16...25 rated operating current, 9.3 @ 32 rated operating current | 
| Altitude | 2000 m | 
| Pollution degree | 3 | 
| Storage ambient air temperature | -50 ðC | 
| Operating ambient air temperature | Open compensated: -25...+55 ðC, Open: -25...+70 ðC, Enclosed: 0...+40 ðC | 
| Utilization category | Circuit breaker: A per IEC60947-2, Motor starter: AC-3 per IEC60947-4-1 | 
| Device construction | Built-in device fixed built-in technique | 
| Mounting | DIN Rail (EN 60715) | 
| Group mounting side by side | Up to 40 ðC (104 ðF) | 
| Resistance to shock | 25 G/11 ms per IEC 60068-2-27 | 
| Resistance to vibration | 5 G/3 ... 150 Hz per IEC 60068-2-6 | 
| Degree of protection | Housing: IP20, Main terminals: IP10 | 