PLC-RSC- 24DC/2X21/FG - Relay Module


Product properties | Product type: Relay Module Product family: PLC-INTERFACE Application: Forcibly guided contacts Operating mode: 100% operating factor Mechanical service life: approx. 107 cycles B10d: 600000 Cycles (AC1; 250ÃVÃ/Ã6ÃA; 1 NO) 900000 Cycles (AC1; 250ÃVÃ/Ã3ÃA; 1ÃNO) 1800000 Cycles (AC1; 250ÃVÃ/Ã1,5ÃA; 1ÃNO) 180000 Cycles (AC15; 250ÃVÃ/Ã3ÃA; 1ÃNO) 560000 Cycles (AC15; 250ÃVÃ/Ã2ÃA; 1ÃNO) 4600000 Cycles (AC15; 250ÃVÃ/Ã0,75ÃA; 1ÃNO) 360000 Cycles (DC13; 24ÃVÃ/Ã3ÃA; 1ÃNO) 740000 Cycles (DC13; 24ÃVÃ/Ã1,5ÃA; 1ÃNO) 4200000 Cycles (DC13; 24ÃVÃ/Ã0,75ÃA; 1ÃNO) Insulation characteristics Insulation: Safe isolation, reinforced insulation Insulation characteristics: Standards/regulations Insulation: Safe isolation, reinforced insulation Overvoltage category: III Pollution degree: 2 |
Electrical properties | Maximum power dissipation for nominal condition: 0.72 W Test voltage (Winding/contact): 4 kVrms (50ÃHz, 1Ãmin., winding/contact) Test voltage (Changeover contact/changeover contact): 2.5 kVrms (50ÃHz, 1Ãmin., changeover contact/changeover contact) Standards/regulations Rated insulation voltage: 250 VÃAC Rated surge voltage: 6 kV |
Input data | Coil side Nominal input voltage UN: 24 VÃDC Input voltage range: 20.2 VÃDC ... 32.4 VÃDC (20ðC) Input voltage range in reference to UN: see diagram Drive and function: monostable Drive (polarity): polarized Typical input current at UN: 30 mA Typical response time: 10 ms Typical release time: 10 ms Coil voltage: 24 VÃDC Protective circuit: Freewheeling diode Operating voltage display: Yellow LED |
Output data | Switching Contact switching type: 2 changeover contacts, forcibly actuated Type of switch contact: Single contact Contact material: AgNi Maximum switching voltage: 250 V AC/DC Minimum switching voltage: 5 V (10ÃmA) Limiting continuous current: 6 A Maximum inrush current: 6 A Min. switching current: 10 mA (5 V) Interrupting rating (ohmic load) max.: 144 W (24ÃVÃDC) 288 W (48ÃVÃDC) 88 W (110ÃVÃDC) 110 W (220ÃVÃDC) 1500 VA (250ÃVÃAC) Switching capacity min.: 150 mW Switching capacity: 3 A (24ÃV, DC13) 3 A (230 V, AC15) Force-guided contacts in accordance with ENÃ61810-3: Type B |
Connection data | Connection method: Screw connection Stripping length: 8 mm Screw thread: M3 Conductor cross section rigid: 0.14 mm² ... 2.5 mm² Conductor cross section flexible: 0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) Conductor cross section AWG: 26 ... 14 Tightening torque: 0.6 Nm ... 0.8 Nm |
Dimensions | Width: 14 mm Height: 80 mm Depth: 104 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection (Relay): RT II (Relay) Degree of protection (Relay base): IP20 (Relay base) Degree of protection (Installation location): ââ°¥ IP54 (Installation location) Ambient temperature (operation): -20°C ... 60°C Ambient temperature (storage/transport): -20°C ... 85°C Altitude: ââ°¤ 2000 m |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant UL, USA Identification: ULÃ508 ULÃ508 Recognized UL, USA/Canada Identification: ULÃ508 ULÃ508 Recognized Shipbuilding approval Certificate: TAE0000196 Corrosive gas test Identification: ISA-S71.04. G3 Harsh Group ENÃ60068-2-60 DNV GL data Temperature: D Humidity: A Vibration: B/C EMC: B Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive Electromagnetic compatibility: Conformance with EMC directive |
Standards and regulations | Standards/regulations Standards/regulations: IEC 60947-5-1 DINÃENÃ61810-3 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |