Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2908204
PHOENIX CONTACT 2908204
PHOENIX CONTACTNot available

TTC-6P-2X1-48DC-PT-I - Surge protection device

Surge protection, consisting of protective plug and base element, with integrated status indicator for two signal wires with common reference potential, e.g., Digital IN/OUT.
Product Code: 2908204
Partner cod.: 2908204
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesIEC test classification: C1
C2
C3
D1
Type: DIN rail module, two-section, divisible
Product type: Surge protection for MCR technology
Product family: TERMITRAB complete
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal voltage UN: 48 VÂDC
Connection dataConnection method: Push-in connection
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section AWG: 24 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/b127379a7f273c4bb57b020c5c3744ea/-S204x204-FJPG
Width: 6.2 mm +0.1Âmm
Height: 105.8 mm
Depth: 100 mm (incl. DIN rail 7.5Âmm)
Material specificationsFlammability rating according to UL 94: V-0
Insulating material: PBT
Housing material: PBT
Mechanical propertiesMechanical data
Open side panel: No
Protective circuitDirection of action: Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC: 53 VÂDC
30 VÂAC
Rated current: 220 mA DC (75°C)
600 mA AC (56°C)
Operating effective current IC at UC: ≤ 5 µA
Residual current IPE: ≤ 10 µA
Nominal discharge current In (8/20) µs (line-ground): 5 kA
Pulse discharge current Iimp (10/350)µs (line-earth): 0.5 kA
Total discharge current Itotal (8/20)µs: 10 kA
Voltage protection level Up (line-earth): ≤ 110 V (C1 - 1ÂkV / 500ÂA)
≤ 150 V (C2 - 10 kV / 5 kA)
≤ 80 V (C3 - 25ÂA)
≤ 90 V (C3 - 50ÂA)
Voltage protection level Up static (line-earth): ≤ 105 V (C1 - 1ÂkV / 500ÂA)
≤ 150 V (C2 - 10 kV / 5 kA)
Response time tA (line-earth): ≤ 1 ns
Input attenuation aE, asym.: typ. 0.3 dB (≤ 480 kHz / 150 Ω)
Cut-off frequency fg (3ÂdB), asym. (PE) in 150ÂΩ system: typ. 1.7 MHz
Capacity (Core-Earth): typ. 1.2 nF
Resistance per path: 1.65 Ω ±20Â%
Surge protection fault message: optical
Max. required back-up fuse: 160 mA DC (FF)
630 mA AC (FF)
Impulse durability (line-earth): C1 - 1ÂkV / 500ÂA
C2 - 10ÂkV / 5ÂkA
C3 - 57ÂA
D1 - 500ÂA
Pulse reset time (line-earth): ≤ 600Âms
Additional technical data
Max. total discharge current I total max (8/20)µs: 20 kA (1x)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 85°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 4000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Standards and regulationsStandards/specifications: IEC 61643-21
Note: 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
EN 61643-21
Standards/specifications: ENÂ61643-21
Note: 2001 + A1:2009 + A2:2013
MountingMounting type: DIN rail: TH 35 - 7.5 mm
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00233.pdf

Approvals_00062.pdf

Approvals_00552.pdf

Approvals_00559.pdf

Approvals_00977.pdf

Approvals_01845.pdf

CAD_data_00023.pdf

Certification_00159.pdf

Certification_00201.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_01018.pdf

Manufacturer_declaration_02339.pdf

Manufacturer_declaration_16327.pdf

Product_information_00033.pdf

Product_information_01020.pdf

Technical_drawing_40598.pdf