Industrial Automation
TTC-6P-1X2-12DC-PT-I - Surge protection device


Product properties | IEC test classification: C1 C2 C3 D1 Type: DIN rail module, two-section, divisible Product type: Surge protection for MCR technology Product family: TERMITRAB complete Wire pairs per module: 1 Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal voltage UN: 12 VÃDC |
Connection data | Connection method: Push-in connection Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section rigid: 0.2 mm² ... 4 mm² Conductor cross section AWG: 24 ... 12 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/b127379a7f273c4bb57b020c5c3744ea/-S204x204-FJPG Width: 6.2 mm +0.1Ãmm Height: 105.8 mm Depth: 100 mm (incl. DIN rail 7.5Ãmm) |
Material specifications | Flammability rating according to UL 94: V-0 Insulating material: PBT Housing material: PBT |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Direction of action: Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground Maximum continuous voltage UC: 15 VÃDC 10 VÃAC Rated current: 600 mA (56ðC) Operating effective current IC at UC: ââ°¤ 100 õA Residual current IPE: ââ°¤ 1 õA Nominal discharge current In (8/20) õs (line-line): 5 kA Nominal discharge current In (8/20) õs (line-ground): 5 kA Pulse discharge current Iimp (10/350)Ãõs (line-line): 0.5 kA Pulse discharge current Iimp (10/350)Ãõs (line-earth): 0.5 kA Total discharge current Itotal (8/20)Ãõs: 10 kA Voltage protection level Up (line-line): ââ°¤ 220 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 350 V (C2 - 10 kV / 5 kA) ââ°¤ 25 V (C3 - 25ÃA) ââ°¤ 35 V (C3 - 100ÃA) Voltage protection level Up (line-earth): ââ°¤ 750 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 750 V (C2 - 10 kV / 5 kA) ââ°¤ 700 V (C3 - 25ÃA) ââ°¤ 750 V (C3 - 100ÃA) Voltage protection level Up static (line-line): ââ°¤ 30 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 81 V (C2 - 10 kV / 5 kA) Voltage protection level Up static (line-earth): ââ°¤ 750 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 750 V (C2 - 10 kV / 5 kA) Response time tA (line-line): ââ°¤ 1 ns Response time tA (line-earth): ââ°¤ 100 ns Input attenuation aE, sym.: typ. 0.3 dB (ââ°¤ 130 kHz/150 é) Cut-off frequency fg (3ÃdB), sym. in 150Ãé system: typ. 420 kHz Capacity (Core-Core): typ. 5.2 nF Resistance per path: 1.65 é ñ20Ã% Surge protection fault message: optical Max. required back-up fuse: 630 mA (FF) Impulse durability (line-line): C1 - 1ÃkV / 500ÃA C2 - 10ÃkV / 5ÃkA C3 - 100ÃA Impulse durability (line-earth): C1 - 1ÃkV / 500ÃA C2 - 10ÃkV / 5ÃkA C3 - 100ÃA D1 - 500ÃA Pulse reset time (line-line): ââ°¤ 700Ãms Pulse reset time (line-earth): ââ°¤ 1500Ãms Additional technical data Max. total discharge current I total max (8/20)Ãõs: 20 kA (1x) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 85°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ââ°¤ 4000 m (amsl) Permissible humidity (operation): 5 % ... 95 % |
Standards and regulations | Standards/specifications: IEC 61643-21 Note: 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 EN 61643-21 Standards/specifications: ENÃ61643-21 Note: 2001 + A1:2009 + A2:2013 |
Mounting | Mounting type: DIN rail: TH 35 - 7.5 mm |
Description other products