PLC-OPT-120UC/V8C/SEN - Solid-state relay module

PLC-INTERFACE for input functions with PLC logic, with Push-in connection and plug-in miniature solid-state relay, for mounting on a DIN rail, 1 N/O contact, input: 120 V AC/110 V DC
Product Code: 2908174
Partner cod.: 2908174
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesProduct type: Solid-state relay module
Product family: PLC-INTERFACE
Application: Input function
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Standards/regulations
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.42 W
Test voltage (Input/output): 2.5 kV (50ÂHz, 1Âmin., input/output)
Input dataNominal input voltage UN: 120 VÂAC
110 VÂDC
Input voltage range in reference to UN: 0.8 ... 1.1
Input voltage range: 96 VÂAC ... 132 VÂAC
88 VÂDC ... 121 VÂDC
Switching threshold "0" signal in reference to UN: ≤ 0.3
Switching threshold "1" signal in reference to UN: ≥ 0.8
Typical input current at UN: 3.5 mA
Typical response time: 6 ms (at UN)
Typical turn-off time: 10 ms (at UN)
Operating voltage display: Yellow LED
Protective circuit: Bridge rectifier
Transmission frequency: 10 Hz
Output dataContact switching type: 1 N/O contact
Design of digital output: electronic
Output voltage range: 5 VÂDC ... 30 VÂDC
Limiting continuous current: 3 mA
Surge voltage protection: > 56 V
Voltage drop at max. limiting continuous current: ≤ 1 V
Output circuit: 2-conductor, floating
Protective circuit: Reverse polarity protection; Polarity protection diode
Surge protection
Connection dataInput side
Connection method: Push-in connection
Stripping length: 8 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 14
Output side
Connection method: Push-in connection
Stripping length: 8 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -25°C ... 70°C
ApprovalsCorrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
ENÂ60068-2-60
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01883.pdf

Manufacturer_declaration_03450.pdf

Manufacturer_declaration_03451.pdf

Manufacturer_declaration_03606.pdf

Manufacturer_declaration_16313.pdf

Product_information_00033.pdf

Product_information_00649.pdf

Technical_drawing_40582.pdf