QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply unit

Primary-switched power supply, QUINTPOWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24VDC/2.5A
Product Code: 2904614
Partner cod.: 2904614
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Input dataAC operation
Nominal input voltage range: 100 VÂAC ... 240 VÂAC
Input voltage range: 100 VÂAC ... 240 VÂAC -15Â%Â...Â+10Â%
Electric strength, max.: 300 VÂAC 30 s
Typical national grid voltage: 120 VÂAC
230 VÂAC
Voltage type of supply voltage: AC/DC
Inrush current: typ. 10 A (at 25°C)
Inrush current integral (I2t): typ. 0.1 A2s
Inrush current limitation: 10 A
Frequency range (fN): 50 Hz ... 60 Hz ±10Â%
16.7 Hz (acc. to ENÂ50163)
Mains buffering time: typ. 31 ms (120ÂVÂAC)
typ. 31 ms (230 VÂAC)
Current consumption: 0.85 A (100ÂVÂAC)
0.7 A (120ÂVÂAC)
0.39 A (230 V AC)
0.37 A (240ÂVÂAC)
Protective circuit: Transient surge protection; Varistor
Typical response time: 500 ms
Input fuse: 4 A (slow-blow, internal)
Recommended breaker for input protection: 6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE: < 0.25 mA (264 V AC, 60 Hz)
< 0.22 mA
DC operation
Input voltage range: 110 VÂDC ... 250 VÂDC -20Â%Â...Â+40Â%
Voltage type of supply voltage: AC/DC
Current consumption: 0.75 A (110ÂVÂDC)
0.33 A (250ÂVÂDC)
Output dataEfficiency: typ. 93 % (120ÂVÂAC)
typ. 94 % (230 V AC)
Nominal output voltage: 24 VÂDC
Setting range of the output voltage (USet): 24 VÂDC ... 27 VÂDC (constant capacity)
Nominal output current (IN): 2.5 A
Static Boost (IStat.Boost): 3.125 A (≤ 40°C)
Dynamic Boost (IDyn.Boost): 4 A (≤Â60°C (onÂ≤Â5Âs/offÂ≥Â5Âs))
Feedback voltage resistance: ≤ 32 VÂDC
Protection against overvoltage at the output (OVP): ≤ 30 VÂDC ±2Â%
Control deviation: < 0.5 % (Static load change 10Â% ... 90Â%)
< 2 % (Dynamic load change 10Â% ... 90Â%, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple: < 40 mVPP (with nominal values)
Short-circuit-proof: yes
No-load proof: yes
Output power: 60 W
75 W
96 W
Maximum no-load power dissipation: < 1 W (120ÂVÂAC)
< 1 W (230 V AC)
Power loss nominal load max.: < 5 W (120ÂVÂAC)
< 4 W (230 V AC)
Crest factor: typ. 1.8 (120ÂVÂAC)
typ. 1.84 (230 V AC)
Rise time: 50 ms (UOutÂ=Â10Â%Â...Â90Â%)
Signal (configurable)
Digital: 0 VÂDC 24 VÂDC 30 mA
Default: 24 VÂDC 30 mA 24ÂVÂDC for UOut >Â0.9ÂxÂUSet
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.14 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.14 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm²
Conductor cross section AWG min.: 26
Conductor cross section AWG max.: 14
Stripping length: 8 mm
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.14 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.14 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm²
Conductor cross section AWG min.: 26
Conductor cross section AWG max.: 14
Stripping length: 8 mm
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Signal
Connection method: Screw connection
Conductor cross section, rigid min.: 0.14 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.14 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm²
Conductor cross section AWG min.: 26
Conductor cross section AWG max.: 14
Stripping length: 8 mm
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Signal output
POut: > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
UOut: > 0.9ÂxÂUSet (LED lights up green)
< 0.9ÂxÂUSet (LED flashes green)
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
3 kV AC (routine test)
Switching frequency: 90 kHz ... 110 kHz (Auxiliary converter stage)
50 kHz ... 195 kHz (Main converter stage)
60 kHz ... 360 kHz (PFC stage)
Product propertiesProduct type: Power supply
Product family: QUINT POWER
MTBF (IEC 61709, SN 29500): > 2000000 h (25°C)
> 1161000 h (40°C)
> 514000 h (60°C)
Environmental protection directive: RoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection class: II
Degree of pollution: 2
Life expectancy (electrolytic capacitors)
Current: 2.5 A
Temperature: 40°C
Time: 323000 h
Additional text: 120ÂVÂAC
Life expectancy (electrolytic capacitors)âۉ€¹
Current: 2.5 A
Temperature: 40°C
Time: 346000 h
Additional text: 230ÂVÂAC
Life expectancy (electrolytic capacitors)âۉ€¹Ãƒ¢Ã¢‚¬Ã¢€¹
Current: 2.5 A
Temperature: 25°C
Time: 915000 h
Additional text: 120ÂVÂAC
Life expectancy (electrolytic capacitors)âۉ€¹Ãƒ¢Ã¢‚¬Ã¢€¹Ãƒ¢Ã¢‚¬Ã¢€¹
Current: 2.5 A
Temperature: 25°C
Time: 980000 h
Additional text: 230ÂVÂAC
DimensionsWidth: 40 mm
Height: 99 mm
Depth: 114 mm
Installation dimensions
Installation distance right/left (active): 15 mm / 15 mm (POutÂ≥50%Â)
Installation distance right/left (passive): 5 mm / 5 mm (POutÂ≥50%Â)
Installation distance right/left (active, passive): 0 mm / 0 mm (POutÂ≤50Â%)
Installation distance top/bottom (active): 30 mm / 30 mm (POutÂ≥50%Â)
Installation distance top/bottom (passive): 30 mm / 30 mm (POutÂ≥50%Â)
Installation distance top/bottom (active, passive): 30 mm / 30 mm (POutÂ≤50Â%)
MountingMounting type: DIN rail mounting
With protective coating: No
Material specificationsFlammability rating according to ULÂ94 (housing / terminal blocks): V0
Housing material: Plastic
Type of housing: Polycarbonate
Hood version: Polycarbonate
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (>Â60°C Derating: 2,5Â%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (start-up type tested): -40°C
Maximum altitude: ≤ 5000 m (> 2000 m, observe derating)
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): 5ÂHz ... 100ÂHz resonance search 2.3g, 90Âmin., resonance frequency 2.3g, 90Âmin. (according to DNV GL Class C)
Standards and regulationsRail applications: ENÂ50121-3-2
ENÂ50121-4
ENÂ50121-5
IEC 62236-3-2
IEC 62236-4
IEC 62236-5
Standard âۉ€œ Limitation of mains harmonic currents: ENÂ61000-3-2
Standard âۉ€œ Safety extra-low voltage: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation: IEC 61558-2-16
IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1
IEC 61010-2-201Â(SELV)
Standard - Safety of transformers: ENÂ61558-2-16
Overvoltage category
EN 61010-1: IIÂ(≤Â5000Âm)
EN 62477-1: IIIÂ(≤Â2000Âm)
ApprovalsATEX
Identification: ULÂ21ÂATEXÂ2597ÂX
ïÃ‹œ II 3 GÂÂÂEx ec nC IIC T4 Gc
IECEx
Identification: IECExÂULDÂ21.0023X
Ex ec nC IIC T4 Gc
UKEX
Identification: UL21UKEX2208X
UL
Identification: ULÂListedÂULÂ61010-1
ULâۉ€¹
Identification: ULÂListedÂULÂ61010-2-201
ULâۉ€¹Ãƒ¢Ã¢‚¬Ã¢€¹
Identification: UL 1310 Class 2 Power Units
ULâۉ€¹Ãƒ¢Ã¢‚¬Ã¢€¹Ãƒ¢Ã¢‚¬Ã¢€¹
Identification: ANSI/ULÂ121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
SIQ
Identification: CB scheme (IEC 61010-1, IEC 61010-2-201)
EMC dataInterference emission: Interference emission in accordance with ENÂ61000-6-3 (residential and commercial) and ENÂ61000-6-4 (industrial)
Noise immunity: Immunity in accordance with ENÂ61000-6-1 (residential), ENÂ61000-6-2 (industrial), and ENÂ61000-6-5 (power station equipment zone), IEC/ENÂ61850-3 (power supply)
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
EMC requirements, power plant: IEC 61850-3
ENÂ61000-6-5
Conducted noise emission: ENÂ55016
ENÂ61000-6-3 (Class B)
Noise emission: Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
ENÂ55016
ENÂ61000-6-3 (Class B)
Harmonic currents
Standards/regulations: ENÂ61000-3-2
ENÂ61000-3-2 (Class A)
Frequency range: 0 kHz ... 2 kHz
Flicker
Standards/regulations: ENÂ61000-3-3
Frequency range: 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations: ENÂ61000-4-2
Electrostatic dischargeâۉ€¹
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: ENÂ61000-4-3
Electromagnetic HF fieldâۉ€¹
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 6 GHz
Test field strength: 20 V/m (Test Level X)
10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: ENÂ61000-4-4
Fast transients (burst)âۉ€¹
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 4 kV (Test Level X - asymmetrical)
Signal: 4 kV (Test Level X - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: ENÂ61000-4-5
Input: 2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: ENÂ61000-4-6
Conducted interferenceâۉ€¹
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Power frequency magnetic field
Standards/regulations: ENÂ61000-4-8
Frequency: 16.67 Hz
50 Hz
60 Hz
50 Hz
60 Hz
0 Hz
Test field strength: 100 A/m
1 kA/m
300 A/m
Additional text: 60 s
3 s
DC, 60Âs
Comments: Criterion A
Frequency range: 50 Hz ... 60 Hz
Voltage dips
Standards/regulations: ENÂ61000-4-11
Voltage: 100 VÂAC
Frequency: 60 Hz
Voltage dip: 70 %
40 %
0 %
Number of periods: 0.5 / 1 / 30 periods
5 / 10 / 50 periods
0.5 / 1 / 5 / 50 periods
Additional text: Test Level 2
Comments: Criterion A
Criterion B
Criterion B
Pulse-shape magnetic field
Standards/regulations: ENÂ61000-4-9
Test field strength: 1000 A/m
Comments: Criterion A
Attenuated sinusoidal oscillations (ring wave)
Standards/regulations: ENÂ61000-4-12
Input: 2 kV (symmetrical)
4 kV (asymmetrical)
Comments: Criterion A
Asymmetrical conducted disturbance variables
Standards/regulations: ENÂ61000-4-16
Test level 1: 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage: 30 V (10Âs)
300 V (1 s)
Test level 2: 16.67 Hz 50 Hz 60 Hz (Test Level 2)
Comments: Criterion A
Attenuated oscillating wave
Standards/regulations: ENÂ61000-4-18
Voltage: 1 kV (symmetrical)
2.5 kV (asymmetrical)
1 kV (symmetrical)
Comments: Criterion A
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01297.pdf

Approvals_01330.pdf

Approvals_01525.pdf

Approvals_01526.pdf

Approvals_01527.pdf

Approvals_01528.pdf

Approvals_01545.pdf

Approvals_01582.pdf

Data_sheet_03845.pdf

Manufacturer_declaration_01302.pdf

Manufacturer_declaration_01303.pdf

Package_slip_02159.pdf

Technical_drawing_39986.pdf

Various_00006.pdf