S-PT-EX(I)-24DC-3/4" - Surge protection device


Notes | General: When the bridge is disconnected, the shield connection is indirectly connected to the housing or reference potential. |
Product properties | IEC test classification: C1 C2 C3 D1 Type: Screw-in module Product type: Surge protection for MCR technology Product family: SURGETRAB Number of positions: 3 Surge protection fault message: none Wire pairs per module: 1 Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal voltage UN: 24 VÃDC |
Connection data | Connection method: Screw connection Screw thread: M3 Tightening torque: 0.6 Nm Conductor cross section flexible: 0.14 mm² ... 1.5 mm² Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section AWG: 26 ... 16 |
Ex data | Maximum inner capacitance Ci: 2 nF Max. internal inductance Li: 1 õH Max. input current Ii: 350 mA (T4 / ââ°¤Ã50ðC) 350 mA (T5 / ââ°¤ 50°C) 350 mA (T6 / ââ°¤ 50°C) Max. input voltage Ui: 30 V max. input power Pi: 3 W Insulation voltage to ground: 500 VÃAC Ambient temperature (operation): -40°C ... 50°C Max. surface temperature: 135°C (T4) 100°C (T5) 85°C (T6) |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/5396ee696346bc4fb1835ec6e6f8616a/-S204x204-FJPG Width: 33.5 mm Height: 33.5 mm Depth: 148 mm |
Material specifications | Color: Steel / stainless steel Housing surface material: nickel-plated Housing material: Zinc die-cast, surface bronzed and nickel-plated |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Direction of action: Line-Line & Line-Earth Ground Maximum continuous voltage UC: 30 VÃDC 21 VÃAC Rated current: 350 mA (50ðC) Operating effective current IC at UC: ââ°¤ 10 õA Residual current IPE: ââ°¤ 2 õA Nominal discharge current In (8/20) õs (line-line): 10 kA Nominal discharge current In (8/20) õs (line-ground): 10 kA (per path) Nominal discharge current In (8/20)Ãõs (shield-ground): 10 kA (optional) Pulse discharge current Iimp (10/350)Ãõs: 1 kA Max. discharge current Imax (8/20) õs maximum (line-line): 10 kA Max. discharge current Imax (8/20) õs maximum (line-earth): 10 kA (per path) Discharge surge current Imax (8/20) õs maximum (shield-ground): 10 kA Nominal pulse current Ian (10/1000) õs (line-line): 30 A Nominal pulse current Ian (10/1000) õs (line-earth): 100 A (per path) Nominal pulse current Ian (10/1000) õs (shield-ground): 100 A Output voltage limitation at 1 kV/õs (line-line) spike: ââ°¤ 50 V Output voltage limitation at 1 kV/õs (line-earth) spike: ââ°¤ 1.4 kV (Direct grounding) Output voltage limitation at 1ÃkV/õs (shield-ground) spike: ââ°¤ 600 V (optional) Output voltage limitation at 1 kV/õs (line-line) static: ââ°¤ 50 V Output voltage limitation at 1 kV/õs (line-earth) static: ââ°¤ 1.4 kV (Direct grounding) Residual voltage at In (conductor-conductor): ââ°¤ 50 V Residual voltage with Ian (10/1000) õs (line-line): ââ°¤ 50 V Voltage protection level Up (line-line): ââ°¤ 50 V (C1 - 0.5 kV / 250 A) ââ°¤ 55 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 55 V (C2 - 2 kV/1 kA) ââ°¤ 55 V (C2 - 10 kV / 5 kA) ââ°¤ 50 V (C3 - 10ÃA) ââ°¤ 50 V (C3 - 25ÃA) ââ°¤ 80 V (D1 - 1 kA) Voltage protection level Up (line-earth): ââ°¤ 1.4 kV (C1 - 1ÃkV / 500ÃA) ââ°¤ 1.4 kV (C2 - 2 kV/1 kA) ââ°¤ 1.4 kV (C2 - 10 kV / 5 kA) ââ°¤ 1.4 kV (C3 - 25ÃA) ââ°¤ 1.4 kV (C3 - 100ÃA) ââ°¤ 1.4 kV (D1 - 1 kA) Voltage protection level Up (shield-ground): ââ°¤ 600 V (C1 - 0.5 kV / 250 A) ââ°¤ 650 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 650 V (C2 - 2 kV/1 kA) ââ°¤ 650 V (C2 - 10 kV / 5 kA) ââ°¤ 650 V (C3 - 10ÃA) ââ°¤ 750 V (C3 - 25ÃA) ââ°¤ 750 V (C3 - 100ÃA) ââ°¤ 650 V (D1 - 1 kA) Response time tA (line-line): ââ°¤ 1 ns Response time tA (line-earth): ââ°¤ 100 ns Response time tA (shield-ground): ââ°¤ 100 ns Input attenuation aE, sym.: typ. 0.5 dB (ââ°¤ 1 MHz / 50 é) typ. 0.2 dB (ââ°¤ 400 kHz / 150 é) Cut-off frequency fg (3ÃdB), sym. in 50Ãé system: typ. 6 MHz Cut-off frequency fg (3ÃdB), sym. in 150Ãé system: typ. 2.5 MHz Resistance per path: 2.2 é ñ10Ã% Surge protection fault message: none Impulse durability (line-line): C1 - 1ÃkV / 500ÃA C2 - 10ÃkV / 5ÃkA C3 - 25ÃA D1 - 1ÃkA Impulse durability (line-earth): C1 - 1ÃkV / 500ÃA C2 - 10ÃkV / 5ÃkA C3 - 100ÃA D1 - 1ÃkA Impulse durability (shield-ground): C1 - 1 ÃkV/500ÃA C2 - 10ÃkV/5ÃkA C3 - 100ÃA D1 - 1ÃkA Alternating current carrying capacity (line-earth): 10ÃA - 1Ãs Alternating current carrying capacity (shield-ground): 10ÃA - 1Ãs |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 Ambient temperature (operation): -40°C ... 50°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ââ°¤ 2000 m (amsl) |
Approvals | Conformity/Approvals ATEX: ïà II 1G Ex ia IIC T4...T6 Ga IECEx: Ex ia IIC T4...T6 Ga |
Standards and regulations | Air clearances and creepage distances Standards/regulations: IEC 60664-1 / ENÃ60079-0 / ENÃ60079-11 Standards/specifications: ENÃ61643-21 ENÃ60079-0 ENÃ60079-11 IEC 60079-0 IEC 60079-11 Note: A2:2013 2018 2012 2017 2011 |
Mounting | Mounting type: direct screw connection |
Description other products