Industrial Automation
PT 1X2-24DC-ST - Surge protection plug


Notes | General Note: Technical data is valid in association with the following specified base elements: PT 1X2+F-BE 2856126 PT 1X2-BE 2856113 |
Product properties | IEC test classification: C1 C2 C3 D1 Type: Male Product type: Surge protection for MCR technology Product family: PLUGTRAB PT Surge protection fault message: none Arrester can be tested with CHECKMASTER from software version:: From SW rev. 1.00 Wire pairs per module: 1 Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal voltage UN: 24 VÃDC |
Connection data | Connection method: Screw connection (in connection with the base element) Screw thread: M3 Tightening torque: 0.5 Nm Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section rigid: 0.2 mm² ... 4 mm² Conductor cross section AWG: 24 ... 12 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/ccdf98a6bdd749498f6c4126115c9c5f/-S204x204-FJPG Width: 17.7 mm Height: 45 mm Depth: 52 mm Horizontal pitch: 1 Div. Complete module width: 17.7 mm Complete module height: 90 mm Complete module depth: 65.5 mm |
Material specifications | Color: Copper Flammability rating according to UL 94: V-0 Housing material: PA 6.6 |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Direction of action: Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground Maximum continuous voltage UC: 28 VÃDC 20 VÃAC Rated current: 450 mA (45ðC) Operating effective current IC at UC: ââ°¤ 5 õA Residual current IPE: ââ°¤ 1 õA (with PT 1X2+F-BE) ââ°¤ 2 õA (with PT 1X2-BE) Nominal discharge current In (8/20) õs (line-line): 10 kA Nominal discharge current In (8/20) õs (line-ground): 10 kA Pulse discharge current Iimp (10/350)Ãõs: 2.5 kA Total discharge current Itotal (8/20)Ãõs: 20 kA Max. discharge current Imax (8/20) õs maximum (line-line): 10 kA Max. discharge current Imax (8/20) õs maximum (line-earth): 10 kA Nominal pulse current Ian (10/1000) õs (line-line): 30 A Output voltage limitation at 1 kV/õs (line-line) spike: ââ°¤ 45 V Output voltage limitation at 1 kV/õs (line-earth) spike: ââ°¤ 450 V (with PT 1X2-BE) ââ°¤ 1 kV (with PT 1X2+F-BE) Output voltage limitation at 1 kV/õs (line-line) static: ââ°¤ 40 V Output voltage limitation at 1 kV/õs (line-earth) static: ââ°¤ 25 V (with PT 1X2-BE) ââ°¤ 50 V (with PT 1X2+F-BE) Residual voltage at In (conductor-conductor): ââ°¤ 40 V Residual voltage with Ian (10/1000) õs (line-line): ââ°¤ 50 V Voltage protection level Up (line-line): ââ°¤ 70 V (C1 - 1ÃkV / 500ÃA) ââ°¤ 70 V (C2 - 10 kV / 5 kA) ââ°¤ 60 V (C2 - 6ÃkVÃ/Ã3ÃkA) ââ°¤ 50 V (C3 - 25ÃA) Voltage protection level Up (line-earth): ââ°¤ 450 V (C1 - 1ÃkV / 500ÃA with PT 1X2-BE) ââ°¤ 550 V (C2 - 10ÃkV / 5ÃkA with PT 1X2-BE) ââ°¤ 1000 V (C2 - 10ÃkV / 5ÃkA with PT 1X2+F-BE) ââ°¤ 500 V (C2 - 6ÃkV / 3ÃkA with PT 1X2-BE) Voltage protection level Up static (line-line): ââ°¤ 40 V (C2 - 10 kV / 5 kA) Voltage protection level Up static (line-earth): ââ°¤ 50 V (C2 - 10ÃkV / 5ÃkA with PT 1X2-BE) ââ°¤ 100 V (C2 - 10ÃkV / 5ÃkA with PT 1X2+F-BE) Response time tA (line-line): ââ°¤ 1 ns Response time tA (line-earth): ââ°¤ 100 ns Input attenuation aE, sym.: typ. 0.5 dB (ââ°¤ 1 MHz / 50 é) typ. 0.2 dB (ââ°¤ 400 kHz / 150 é) typ. 0.1 dB (ââ°¤Ã70ÃkHzÃ/Ã600Ãé) Cut-off frequency fg (3ÃdB), sym. in 50Ãé system: typ. 4.5 MHz Cut-off frequency fg (3ÃdB), sym. in 150Ãé system: typ. 1.5 MHz Cut-off frequency fg (3ÃdB), sym. in 600Ãé system: typ. 600 kHz Capacity (Core-Core): typ. 1.4 nF Capacity (Core-Earth): typ. 4 pF (with PT 1X2-BE) typ. 2 pF (with PT 1X2+F-BE) Resistance per path: 2.2 é ñ10Ã% Surge protection fault message: none Max. required back-up fuse: 500 mA (T) Impulse durability (line-line): C1 - 1ÃkV / 500ÃA C2 - 6ÃkV / 3ÃkA C2 - 10ÃkV / 5ÃkA C3 - 25ÃA Impulse durability (line-earth): C1 - 1ÃkV / 500ÃA C2 - 6ÃkV / 3ÃkA C2 - 10ÃkV / 5ÃkA D1 - 2.5ÃkA |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 85°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ââ°¤ 2000 m (amsl) |
Standards and regulations | Standards/specifications: IEC 61643-21 ENÃ61643-21 Note: 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 2001 + A1:2009 + A2:2013 |
Mounting | Mounting type: on base element |