PHOENIX CONTACT 2856032
PHOENIX CONTACT 2856032
PHOENIX CONTACTNot available

PT 1X2-24DC-ST - Surge protection plug

PT protective connector with protective circuit for a 2-wire floating signal circuit. HART-compatible.
Product Code: 2856032
Partner cod.: 2856032
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
NotesGeneral
Note: Technical data is valid in association with the following specified base elements:
PT 1X2+F-BE 2856126
PT 1X2-BE 2856113
Product propertiesIEC test classification: C1
C2
C3
D1
Type: Male
Product type: Surge protection for MCR technology
Product family: PLUGTRAB PT
Surge protection fault message: none
Arrester can be tested with CHECKMASTER from software version:: From SW rev. 1.00
Wire pairs per module: 1
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal voltage UN: 24 VÂDC
Connection dataConnection method: Screw connection (in connection with the base element)
Screw thread: M3
Tightening torque: 0.5 Nm
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section AWG: 24 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/ccdf98a6bdd749498f6c4126115c9c5f/-S204x204-FJPG
Width: 17.7 mm
Height: 45 mm
Depth: 52 mm
Horizontal pitch: 1 Div.
Complete module width: 17.7 mm
Complete module height: 90 mm
Complete module depth: 65.5 mm
Material specificationsColor: Copper
Flammability rating according to UL 94: V-0
Housing material: PA 6.6
Mechanical propertiesMechanical data
Open side panel: No
Protective circuitDirection of action: Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC: 28 VÂDC
20 VÂAC
Rated current: 450 mA (45°C)
Operating effective current IC at UC: ≤ 5 µA
Residual current IPE: ≤ 1 µA (with PT 1X2+F-BE)
≤ 2 µA (with PT 1X2-BE)
Nominal discharge current In (8/20) µs (line-line): 10 kA
Nominal discharge current In (8/20) µs (line-ground): 10 kA
Pulse discharge current Iimp (10/350)µs: 2.5 kA
Total discharge current Itotal (8/20)µs: 20 kA
Max. discharge current Imax (8/20) µs maximum (line-line): 10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth): 10 kA
Nominal pulse current Ian (10/1000) µs (line-line): 30 A
Output voltage limitation at 1 kV/µs (line-line) spike: ≤ 45 V
Output voltage limitation at 1 kV/µs (line-earth) spike: ≤ 450 V (with PT 1X2-BE)
≤ 1 kV (with PT 1X2+F-BE)
Output voltage limitation at 1 kV/µs (line-line) static: ≤ 40 V
Output voltage limitation at 1 kV/µs (line-earth) static: ≤ 25 V (with PT 1X2-BE)
≤ 50 V (with PT 1X2+F-BE)
Residual voltage at In (conductor-conductor): ≤ 40 V
Residual voltage with Ian (10/1000) µs (line-line): ≤ 50 V
Voltage protection level Up (line-line): ≤ 70 V (C1 - 1ÂkV / 500ÂA)
≤ 70 V (C2 - 10 kV / 5 kA)
≤ 60 V (C2 - 6ÂkVÂ/Â3ÂkA)
≤ 50 V (C3 - 25ÂA)
Voltage protection level Up (line-earth): ≤ 450 V (C1 - 1ÂkV / 500ÂA with PT 1X2-BE)
≤ 550 V (C2 - 10ÂkV / 5ÂkA with PT 1X2-BE)
≤ 1000 V (C2 - 10ÂkV / 5ÂkA with PT 1X2+F-BE)
≤ 500 V (C2 - 6ÂkV / 3ÂkA with PT 1X2-BE)
Voltage protection level Up static (line-line): ≤ 40 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-earth): ≤ 50 V (C2 - 10ÂkV / 5ÂkA with PT 1X2-BE)
≤ 100 V (C2 - 10ÂkV / 5ÂkA with PT 1X2+F-BE)
Response time tA (line-line): ≤ 1 ns
Response time tA (line-earth): ≤ 100 ns
Input attenuation aE, sym.: typ. 0.5 dB (≤ 1 MHz / 50 Ω)
typ. 0.2 dB (≤ 400 kHz / 150 Ω)
typ. 0.1 dB (≤Â70ÂkHzÂ/Â600ÂΩ)
Cut-off frequency fg (3ÂdB), sym. in 50ÂΩ system: typ. 4.5 MHz
Cut-off frequency fg (3ÂdB), sym. in 150ÂΩ system: typ. 1.5 MHz
Cut-off frequency fg (3ÂdB), sym. in 600ÂΩ system: typ. 600 kHz
Capacity (Core-Core): typ. 1.4 nF
Capacity (Core-Earth): typ. 4 pF (with PT 1X2-BE)
typ. 2 pF (with PT 1X2+F-BE)
Resistance per path: 2.2 Ω ±10Â%
Surge protection fault message: none
Max. required back-up fuse: 500 mA (T)
Impulse durability (line-line): C1 - 1ÂkV / 500ÂA
C2 - 6ÂkV / 3ÂkA
C2 - 10ÂkV / 5ÂkA
C3 - 25ÂA
Impulse durability (line-earth): C1 - 1ÂkV / 500ÂA
C2 - 6ÂkV / 3ÂkA
C2 - 10ÂkV / 5ÂkA
D1 - 2.5ÂkA
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 85°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m (amsl)
Standards and regulationsStandards/specifications: IEC 61643-21
ENÂ61643-21
Note: 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
2001 + A1:2009 + A2:2013
MountingMounting type: on base element
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00062.pdf

Approvals_00217.pdf

Approvals_00218.pdf

Approvals_01594.pdf

Approvals_01595.pdf

Approvals_01596.pdf

Approvals_01651.pdf

Approvals_01652.pdf

Approvals_01834.pdf

Certification_00158.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_00644.pdf

Manufacturer_declaration_02067.pdf

Manufacturer_declaration_15189.pdf

Product_information_00033.pdf

Product_information_01018.pdf

Technical_drawing_38841.pdf