Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2800995
PHOENIX CONTACT 2800995
PHOENIX CONTACTNot available

PT-IQ-3-HF+F-12DC-UT - Surge protection device

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for three signal wires with common reference potential. For HF applications and telecommunications interfaces without supply voltage (up to 90 Mbps).
Product Code: 2800995
Partner cod.: 2800995
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
NotesGeneral
Note: Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Product propertiesIEC test classification: C1
C2
C3
D1
Type: DIN rail module, two-section, divisible
Product type: Surge protection for information technology
Product family: PLUGTRAB IQ
Surge protection fault message: Optical, multi-stage
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal voltage UN: 12 VÂDC
Connection dataConnection method: Screw connection
Screw thread: M3
Tightening torque: 0.5 Nm
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section AWG: 24 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fc46ccf10e2bae4da270189f6d2038dc/-S204x204-FJPG
Width: 17.7 mm
Height: 91.1 mm
Depth: 77.5 mm (incl. DIN rail 7.5Âmm)
Horizontal pitch: 1 Div.
Material specificationsFlammability rating according to UL 94: V-0
Housing material: PA 6.6
Mechanical propertiesMechanical data
Open side panel: No
Protective circuitDirection of action: Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC: 15 VÂDC
10 VÂAC
Rated current: 600 mA (40°C)
Operating effective current IC at UC: ≤ 100 µA (per path)
Residual current IPE: ≤ 10 µA
Nominal discharge current In (8/20) µs (line-line): 10 kA
Nominal discharge current In (8/20) µs (line-ground): 10 kA
Pulse discharge current Iimp (10/350)µs (line-earth): 2.5 kA
Pulse discharge current Iimp (10/350)µs (line-signalground): 2.5 kA
Total discharge current Itotal (8/20)µs: 20 kA
Voltage protection level Up (line-line): ≤ 40 V (C3 - 25ÂA)
≤ 90 V (C1 - 1ÂkV / 500ÂA)
≤ 145 V (C2 - 10 kV / 5 kA)
≤ 40 V (C3 - 50ÂA)
Voltage protection level Up (line-earth): ≤ 900 V (C3 - 25ÂA)
≤ 730 V (C1 - 1ÂkV / 500ÂA)
≤ 900 V (C2 - 10 kV / 5 kA)
≤ 900 V (C3 - 50ÂA)
Voltage protection level Up (line-signalground): ≤ 90 V (C1 - 1ÂkV / 500ÂA)
≤ 145 V (C2 - 10 kV / 5 kA)
≤ 40 V (C3 - 25ÂA)
≤ 40 V (C3 - 50ÂA)
Voltage protection level Up static (line-line): ≤ 55 V (C1 - 1ÂkV / 500ÂA)
Voltage protection level Up static (line-signalground): ≤ 55 V (C1 - 1ÂkV / 500ÂA)
Response time tA (line-line): ≤ 1 ns
Response time tA (line-earth): ≤ 100 ns
Response time tA (line-signalground): ≤ 1 ns
Input attenuation aE, sym.: typ. 0.3 dB (≤ 10 MHz/150 Ω)
Input attenuation aE, asym.: typ. 0.3 dB (≤ 10 MHz/150 Ω)
Cut-off frequency fg (3ÂdB), sym. in 150ÂΩ system: typ. 60 MHz
Cut-off frequency fg (3ÂdB), asym. (signal ground) in 150ÂΩ system: typ. 60 MHz
Capacity (Core-Core): typ. 30 pF
Capacity (line-signalground): typ. 30 pF
Resistance per path: 1.2 Ω ±5Â%
Surge protection fault message: Optical, multi-stage
Max. required back-up fuse: 600 mA (FF)
Impulse durability (line-line): C1 - 1ÂkV / 500ÂA
C2 - 10ÂkV / 5ÂkA
C3 - 50ÂA
Impulse durability (line-earth): C1 - 1ÂkV / 500ÂA
C2 - 10ÂkV / 5ÂkA
C3 - 50ÂA
D1 - 2.5ÂkA
Impulse durability (line-signalground): C1 - 1ÂkV / 500ÂA
C2 - 10ÂkV / 5ÂkA
C3 - 50ÂA
D1 - 2,5ÂkA
Pulse reset time (line-line): ≤ 15Âms
Pulse reset time (line-earth): ≤ 15Âms
Pulse reset time (line-signalground): ≤ 15Âms
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 4000 m (amsl)
Standards and regulationsAir clearances and creepage distances
Standards/regulations: IEC 60664-1
Standards/specifications: IEC 61643-21
ENÂ61643-21
ENÂ61000-6-2
ENÂ61000-6-3
Note: 2000 + A1:2008 + A2:2012
2001 + A1:2009
2007 + A1:2011
2005
MountingMounting type: DIN rail: 35 mm
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00062.pdf

Approvals_01843.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_00690.pdf

Manufacturer_declaration_02072.pdf

Manufacturer_declaration_15029.pdf

Package_slip_00405.pdf

Product_information_00033.pdf

Product_information_01016.pdf

Technical_drawing_38495.pdf