Industrial Automation
S-PT-EX-24DC - Surge protection device


Product properties | IEC test classification: C1 C2 C3 D1 Type: Screw-in module Product type: Surge protection for MCR technology Product family: SURGETRAB Number of positions: 2 Wire pairs per module: 1 Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal voltage UN: 24 VÃDC |
Connection data | Connection method: Individual wires |
Ex data | Maximum inner capacitance Ci: 1.65 nF Max. internal inductance Li: 1 õH Max. input current Ii: 500 mA (T4 / ââ°¤ 75°C) 500 mA (T5 / ââ°¤ 75°C) 500 mA (T6 / ââ°¤ 60°C) Max. input voltage Ui: 36 VÃDC max. input power Pi: 3 W Insulation voltage to ground: 500 VÃAC Ambient temperature (operation): -40°C ... 75°C (T4) -40°C ... 75°C (T5) -40°C ... 60°C (T6) Operating temperature range: -40°C ... 100°C (T4) -40°C ... 75°C (T5) -40°C ... 60°C (T6) Max. surface temperature: 135°C (T4) 100°C (T5) 85°C (T6) |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9bafd143f38ab44d8495d32957c5c34f/-S204x204-FJPG Width: 28 mm Height: 28 mm Depth: 79 mm |
Material specifications | Color: Steel / stainless steel Seal material: NBR Housing material: Stainless steel 1.4404 ASTMÃ316L |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Direction of action: Line-Line & Line-Earth Ground Maximum continuous voltage UC: 36 VÃDC 25 VÃAC Operating effective current IC at UC: ââ°¤ 5 õA Residual current IPE: ââ°¤ 2 õA Nominal discharge current In (8/20) õs (line-line): 260 A Nominal discharge current In (8/20) õs (line-ground): 10 kA Pulse discharge current Iimp (10/350)Ãõs: 1 kA Total discharge current Itotal (8/20)Ãõs: 20 kA Total discharge current Itotal (10/350)Ãõs: 2 kA Max. discharge current Imax (8/20) õs maximum (line-line): 260 A Max. discharge current Imax (8/20) õs maximum (line-earth): 20 kA Nominal pulse current Ian (10/1000) õs (line-line): 50 A Output voltage limitation at 1 kV/õs (line-line) spike: ââ°¤ 130 V Output voltage limitation at 1 kV/õs (line-earth) spike: ââ°¤ 1.1 kV Output voltage limitation at 1 kV/õs (line-line) static: ââ°¤ 60 V Voltage protection level Up (line-line): ââ°¤ 65 V (C3 - 10ÃA) Voltage protection level Up (line-earth): ââ°¤ 1.1 kV (C3 - 100ÃA) ââ°¤ 1.1 kV (C1 - 1ÃkV / 500ÃA) ââ°¤ 1.2 kV (C2 - 10 kV / 5 kA) Response time tA (line-line): ââ°¤ 1 ns Response time tA (line-earth): ââ°¤ 100 ns Input attenuation aE, sym.: typ. 0.1 dB (30 MHz / 50 é) typ. 0.1 dB (6 MHz / 150 é) Cut-off frequency fg (3ÃdB), sym. in 50Ãé system: typ. 70 MHz Cut-off frequency fg (3ÃdB), sym. in 150Ãé system: typ. 40 MHz Capacity (Core-Core): typ. 20 pF Capacity (Core-Earth): typ. 5 pF Surge protection fault message: none Impulse durability (line-line): C3 - 25ÃA Impulse durability (line-earth): C1 - 1ÃkV / 500ÃA C2 - 10ÃkV / 5ÃkA C3 - 100ÃA D1 - 1ÃkA Alternating current carrying capacity (line-earth): 10ÃA - 1Ãs |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 Ambient temperature (operation): -40°C ... 80°C (non-Ex) Altitude: ââ°¤ 2000 m (amsl) |
Approvals | Conformity/Approvals ATEX: ïà II 1 G Ex ia IIC T4...T6 ïà II 2 G Ex d IIC T4...T6 ïà II 1 D Ex iaD 20 IP6x T85°C...135°C ïà II 2 D Ex tD A21 IP6x T85°C...135°C IECEx: Ga Ex ia IIC T4...T6 Ex d IIC T4...T6 Ex iaD IP6x T85°C...135°C Ex tD A21 IP6x T85°C...135°C |
Standards and regulations | Air clearances and creepage distances Standards/regulations: IEC 60664-1 / IEC 60079-11 Standards/specifications: ENÃ61643-21 ENÃ60079-0 ENÃ60079-1 ENÃ60079-11 ENÃ60079-31 IEC 60079-0 IEC 60079-1 IEC 60079-11 IEC 60079-31 Note: A2:2013 2018 2007 2012 2009 2017 2007 2011 2008 |
Mounting | Mounting type: M20 |
Description other products