Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/aad81a7f06bc4f4aa1cf74b52bb32fb4/-S204x204-FJPG Width: 45 mm Height: 126.1 mm Depth: 74 mm Note on dimensions: The depth applies when a THÃ35-7.5 DIN rail is used (in accordance with ENÃ60715). |
Interfaces | EtherNet/IPâ⢠Number of interfaces: 2 Connection method: RJ45 jack Note on the connection method: Auto negotiation and autocrossing Transmission speed: 10/100 Mbps (Half or full duplex mode (automatic detection, can be adjusted manually)) Transmission physics: Ethernet in RJ45 twisted pair AxiolineÃFÃlocal bus Number of interfaces: 1 Connection method: Bus base module Transmission speed: 100 Mbps Service Number of interfaces: 1 Connection method: USB type C (from HWÃ01) Micro USB type B (HW 00) |
System properties | System limits Number of supported devices: max. 63 (per station) Number of local bus devices that can be connected: max. 63 |
Product properties | Type: block modular Product type: I/O component Product family: AxiolineÃF Mounting position: any (observe temperature derating) Scope of delivery: including bus base module and AxiolineÃF connector Insulation characteristics Overvoltage category: II (IEC 60664-1, ENÃ60664-1) Pollution degree: 2 (IEC 60664-1, ENÃ60664-1) |
Electrical properties | Potentials: Communications power U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Current draw: max. 583 mA (2.0ÃA at UBus, UL = 24 V, HWÃ00) max. 670 mA (2.5ÃA at UBus, UL = 24 V, HWÃ01 or later) Power consumption: max. 14 W (2.0ÃA at UBus, UL = 24 V, HWÃ00) max. 16 W (2.5ÃA at UBus, UL = 24 V, HWÃ01 or later) Protective circuit: Surge protection; electronic Reverse polarity protection; electronic Potentials: AxiolineÃF local bus supply (U Supply voltage: 5 VÃDC (via bus base module) Power supply unit: max. 2 A (HW 00) max. 2.5 A (from HWÃ01) Electrical isolation/isolation of the voltage ranges Test voltage: Ethernet interface 1 / Ethernet interface 2: 1500 VÃAC, 50 Hz, 1 min. Test voltage: Ethernet interface 1 / 24 V communications voltage (UL) feed-in: 1500 VÃAC, 50 Hz, 1 min. Test voltage: Ethernet interface 2 / 24 V communications voltage (UL) feed-in: 1500 VÃAC, 50 Hz, 1 min. Test voltage: Ethernet interface 1 / functional ground: 1500 VÃAC, 50 Hz, 1 min. Test voltage: Ethernet interface 2 / functional ground: 1500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V communications voltage (UL) feed-in / functional ground: 500 VÃAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: AxiolineÃF connector Note on the connection method: Please observe the information provided on conductor cross sections in the ââ¬Ã AxiolineÃF: system and installationâ⬠user manual. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm AxiolineÃF connector Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the ââ¬Ã AxiolineÃF: system and installationâ⬠user manual. Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C (Mounting position: wall mounting on horizontal DIN rail) -25°C ... 55°C (Mounting position: any) Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) |
Mounting | Mounting type: DIN rail mounting Mounting position: any (observe temperature derating) |
Description other products