Industrial Automation
AXL E PN DIO16 M12 6M - Digital module


Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/a7ea2daf39eda94f8a0cd3e02b11c54f/-S204x204-FJPG Width: 60 mm Height: 185 mm Depth: 38 mm Drill hole spacing: 198.5 mm Note on dimensions: The height is 194.5Ãmm including the mounting panel. With fixing clips pulled out, the height is 212Ãmm. The depth is 38Ãmm including the mounting panel (30.5Ãmm without the mounting panel). |
Material specifications | Housing material: Zinc die-cast |
Interfaces | PROFINET Number of interfaces: 2 Connection method: M12 fast connection technology Note on the connection method: D-coded Number of positions: 4 Transmission speed: 100 Mbps (with auto negotiation) PROFINETââ¬Ã¢¹ Equipment type: PROFINET-Device System-specific protocols: PROFINET protocols LLDP PROFINET protocols MRP client PROFINET protocols DCP PROFINET protocols DCE/RPC Protocols supported: SNMP v1 HTTP TFTP FTP |
Input data | Digital Input name: Digital inputs Description of the input: EN 61131-2 types 1 and 3 Number of inputs: 16 Cable length: max. 30 m (to the sensor) Connection method: M12 connector, double occupancy Connection technology: 4-conductor Input voltage range "0" signal: 0 V ... 5 VÃDC Input voltage range "1" signal: 11 VÃDC ... 30 VÃDC Nominal input voltage UIN: 24 VÃDC Nominal input current at UIN: typ. 3 mA Sensor current per channel: typ. 75 mA (from US) Total sensor current: max. 1.2 A (per device) Input filter time: < 1000 õs Protective circuit: Overload protection, short-circuit protection of sensor supply |
Output data | Digital Output name: Digital outputs Connection method: M12 connector, double occupancy Connection technology: 3-conductor Number of outputs: 16 Protective circuit: Overload protection, short-circuit protection of outputs; yes Output voltage: 24 VÃDC Limitation of the voltage induced on circuit interruption: -28 V ... -17 V Maximum output current per channel: 500 mA Nominal output voltage: 24 VÃDC (from voltage US) Output voltage range: 18 VÃDC ... 31.2 VÃDC Output voltage when switched off: max. 1 V Output current when switched off: max. 20 õA Nominal load, inductive: 12 VA (1.2 H, 48 é, with nominal voltage) Nominal load, ohmic: 12 W (48 é, with nominal voltage) Switching frequency: max. 5500 per second (with at least 50ÃmA load current) max. 1 per second (with inductive load) Reverse voltage resistance to short pulses: Reverse voltage proof Behavior with overload: Auto restart Signal delay: max. 150 õs (when switched on) max. 200 õs (when switched off) Overcurrent shut-down: min. 0.7 A |
Product properties | Type: Stand-Alone Product type: I/O component Product family: AxiolineÃE |
Electrical properties | Potentials Voltage supply US: 24 VÃDC Power supply at US: max. 4 A Current consumption from US: typ. 8 mA max. 1.2 A Supply: Module electronics, sensors, and actuators Designation: Module electronics, sensors and actuators (US) Connection method: M12 connector (T-coded) Number of positions: 4 Supply voltage: 24 VÃDC Supply voltage range: 18 VÃDC ... 31.2 VÃDC (including all tolerances, including ripple) Current consumption: typ. 190 mA ñ15Ã% (at 24 V DC) max. 12 A Supply: Actuators Designation: Supply of actuators (UA) for additional devices Connection method: M12 connector (T-coded) Number of positions: 4 Supply voltage: 24 VÃDC Supply voltage range: 18 VÃDC ... 31.2 VÃDC (including all tolerances, including ripple) Current consumption: typ. 3 mA ñ15Ã% (at 24 V DC) max. 12 A Electrical isolation/isolation of the voltage ranges Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (EthernetÃ1): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (EthernetÃ2): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/FE: 500 VÃAC, 50 Hz, 1 min. Test voltage: Bus connection (EthernetÃ1)/FE: 500 VÃAC, 50 Hz, 1 min. Test voltage: Bus connection (EthernetÃ2)/FE: 500 VÃAC, 50 Hz, 1 min. Test voltage: Bus connection (EthernetÃ1)/bus connection (EthernetÃ2): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs/outputs): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply)/bus connection (EthernetÃ1): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply)/bus connection (EthernetÃ2): 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply)/FE: 500 VÃAC, 50 Hz, 1 min. |
Connection data | Connection method: M12 connector |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP65/IP67 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Ambient temperature (storage/transport): -25°C ... 85°C Permissible humidity (operation): 5 % ... 95 % Permissible humidity (storage/transport): 5 % ... 95 % |
Standards and regulations | Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) |
Mounting | Mounting type: Wall mounting or DIN rail mounting; both with mounting panel. |
Description other products