Industrial Automation

| Product properties | Product type: Data cable by the meter Sensor type: Ethernet Number of positions: 8 Application: Standard Shielded: yes |
| Electrical properties | Transmission medium: Copper |
| Interfaces | Signal type/category: Ethernet CAT6A, 10 Gbps |
| Connector | Connection 1 Type: free cable end Connection 2 Type: free cable end |
| Cable/line | Cable length: 100 m Ethernet 10 GbitÃ[94F] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/0314c1656ba7d3438a5ae0749b98c42e/-S204x204-FJPG Cable weight: 42 kg/km UL AWM Style: 20963 (80°C/30 V) Number of positions: 8 Shielded: yes Cable type: Ethernet 10 GbitÃ[94F] Conductor structure: 4x2xAWG26/7; S/FTP Signal runtime: 5.13 ns/m Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Conductor cross section: 4x 2x 0.14 mm² Wire diameter incl. insulation: 1.04 mm External cable diameter: 6.4 mm ñ0.2Ãmm Outer sheath, material: PUR External sheath, color: water blue RALÃ5021 Conductor material: Bare Cu litz wires Material wire insulation: Foamed PE Single wire, color: white/blue-blue, white/orange-orange, white/green-green, white/brown-brown Thickness, outer sheath: 0.65 mm Twisted pairs: 2 cores to the pair Type of pair shielding: Aluminum-lined foil Overall twist: 4 pairs for core Optical shield covering: 70 % Insulation resistance: ââ°¥ 500 Mé*km Loop resistance: ââ°¤ 290.00 é/km Wave impedance: 100 é ñ5Ãé (at 100 MHz) Cable capacity: 47 nF/km Nominal voltage, cable: ââ°¤ 100 V Test voltage Core/Core: 700 V (50ÃHz, 1Ãmin.) Test voltage Core/Shield: 700 V (50ÃHz, 1Ãmin.) Minimum bending radius, fixed installation: 4 x D Minimum bending radius, flexible installation: 8 x D Smallest bending radius, fixed installation: 26 mm Smallest bending radius, movable installation: 52 mm Tensile strength: ââ°¤ 100 N Near end crosstalk attenuation (NEXT): 75.3 dB (with 1 MHz) 66.3 dB (at 4 Ãà Hz) 61.8 dB (at 8ÃÃà Hz) 60.3 dB (at 10 MHz) 57.2 dB (at 16 MHz) 55.8 dB (at 20ÃÃà Hz) 54.3 dB (at 25ÃMHz) 52.8 dB (at 31.25ÃÃà Hz) 48.4 dB (at 62.5ÃÃà Hz) 45.3 dB (at 100 MHz) 40.8 dB (at 200 MHz) 39.3 dB (at 250ÃMHz) 38.1 dB (at 300ÃMHz) 38.1 dB (at 400ÃMHz) 38.1 dB (at 500ÃMHz) Power-summated near end crosstalk attenuation (PSNEXT): 72.3 dB (with 1 MHz) 63.3 dB (at 4 Ãà Hz) 58.8 dB (at 8ÃÃà Hz) 57.3 dB (at 10 MHz) 54.2 dB (at 16 MHz) 52.8 dB (at 20ÃÃà Hz) 51.3 dB (at 25ÃMHz) 49.9 dB (at 31.25ÃÃà Hz) 45.4 dB (at 62.5ÃÃà Hz) 42.3 dB (at 100 MHz) 37.8 dB (at 200 MHz) 36.3 dB (at 250ÃMHz) 35.1 dB (at 300ÃMHz) 33.3 dB (at 400ÃMHz) 31.8 dB (at 500ÃMHz) Return attenuation (RL): 20 dB (with 1 MHz) 23 dB (at 4 Ãà Hz) 24.5 dB (at 8ÃÃà Hz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20ÃÃà Hz) 24.2 dB (at 25ÃMHz) 23.3 dB (at 31.25ÃÃà Hz) 20.7 dB (at 62.5ÃÃà Hz) 19 dB (at 100 MHz) 16.4 dB (at 200 MHz) 15.6 dB (at 250ÃMHz) 15.6 dB (at 300ÃMHz) 15.6 dB (at 400ÃMHz) 15.6 dB (at 500ÃMHz) Shield attenuation: 3.1 dB (with 1 MHz) 5.7 dB (at 4 Ãà Hz) 8 dB (at 8ÃÃà Hz) 8.9 dB (at 10 MHz) 11.2 dB (at 16 MHz) 12.6 dB (at 20ÃÃà Hz) 14.1 dB (at 25ÃMHz) 15.8 dB (at 31.25ÃÃà Hz) 22.5 dB (at 62.5ÃÃà Hz) 28.7 dB (at 100 MHz) 41.4 dB (at 200 MHz) 46.6 dB (at 250ÃMHz) 51.4 dB (at 300ÃMHz) 60.1 dB (at 400ÃMHz) 67.9 dB (at 500ÃMHz) ââ°¥ 80 dB (at 30 ... 100 MHz) Halogen-free: according to IEC 60754-1 Flame resistance: according to IEC 60332-1-2 Resistance to oil: in accordance with DINÃENÃ60811-2-1 Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation) -20°C ... 80°C (Cable, flexible installation) Ambient temperature (installation): -20°C ... 80°C |
Description other products