PHOENIX CONTACT 1278515
PHOENIX CONTACT 1278515
PHOENIX CONTACTNot available

UCT-TMC (30X8) - Marker for end clamp

Marker for end clamp, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: latching, Number of individual labels: 5, text field height: 8 mm, text field width: 30 mm
Product Code: 1278515
Partner cod.: 1278515
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Description
Tecnichal data
NotesGeneral: Can be labeled via thermal transfer
Product propertiesProduct type: Terminal marking
Area of application: E/NS 35 N end bracket
Data management status
Article revision: 01
Marking
Number of individual labels: 5
Number of individual labels per row: 1
Identification technology: Thermal transfer for sheets and cards, UV LED technology, direct laser marking
DimensionsWidth: 8 mm
Text field width: 30.00 mm
Text field height: 8.00 mm
Length: 30 mm
Material specificationsColor: white
Material: PC
Flammability rating according to UL 94: V2
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Components: free from silicone and halogen
Environmental and real-life conditionsTest for substances that would hinder coating with paint or varnish
Result: Test passed
Scratch test for the determining scratch resistance
Specification: DIN EN ISO 1518-1:2019-10 (following)
Requirements: ≥ 5 N
Result: Test passed
Tesafilm test
Specification: DIN EN ISO 2409:2013 (following)
Result: Test passed
UV resistance
Specification: ISO 4892-2:2013-03 (following)
IEC 60068-2-2:2007-07
Result: Test passed
Test duration: 96 h
Duration: 96 h
Temperature for testing: 120 °C
Wipe resistance of inscriptions
Specification: DIN EN 61010-1 (VDE 0411-01):2020-03
DIN EN 62208 (VDE 0660-511):2012-06 (in parts)
Isopropyl
[CAS No. 67-63-0]: Test passed
n-Hexane
[CAS No. 110-54-3]: Test passed
Water + Petroleum ether
[CAS No. 64742-82-1]: Test passed
Testing in a condensation changing climate in the presence of sulfur dioxide
Specification: DIN 50018:2013-05
Result: Test passed
Climate level: AHT 1.0 S
Cycles: 2
Salt spray test
Specification: DIN EN 60068-2-11:2000-02
Result: Test passed
Test duration: 96 h
Ambient conditions
Ambient temperature (operation): -40 °C ... 120 °C
Recommended ambient temperature (storage/transport): 23 °C
Recommended humidity (storage/transport): 50 %
Shelf life: 2 years
Standards and regulationsWipe resistance: DIN EN 61010-1 (VDE 0411-1)
MountingMounting type: latching
Description
UCT-TMC (30X8) Codificatore