VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2


Notes | General Note: The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area. |
Product properties | IEC test classification: PV I / II PV T1 / T2 EN type: T1 / T2 IEC power supply system: DC Type: DIN rail module, two-section, divisible Distance between live and grounded parts: 8 mm Product type: PV arrester Product family: VALVETRAB MS Installation location: Interior Installation location of the disconnect device: Internal Accessibility: Accessible Connection configuration: Y configuration SPD failure behavior: OCFM (Open-Circuit Failure Mode) Surge protection fault message: Optical, remote indicator contact Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Indicator/remote signaling Connection name: Remote fault indicator contact Switching function: Changeover contact Operating voltage: 5 VÃAC ... 250 VÃAC 30 VÃDC Operating current: 5 mA AC ... 1.5 A AC 1 AÃDC |
Connection data | Connection method: Screw connection Fork-type cable lug Screw thread: M5 Tightening torque: 3 Nm (1.5Ãmm² ... 16Ãmm²) 4.5 Nm (25Ãmm²Ã...Ã35Ãmm²) Stripping length: 16 mm Conductor cross section flexible: 1.5 mm² ... 25 mm² 1.5 mm² ... 16 mm² Conductor cross section rigid: 1.5 mm² ... 35 mm² Conductor cross section AWG: 15 ... 2 Remote fault indicator contact Connection method: Plug-in/screw connection via COMBICON Screw thread: M2 Tightening torque: 0.25 Nm Stripping length: 7 mm Conductor cross section flexible: 0.14 mm² ... 1.5 mm² Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/0e4a0832d4206348bed6ca2ea11b5b69/-S204x204-FJPG Width: 53.4 mm Height: 98.7 mm Depth: 65.7 mm (incl. DIN rail 7.5Ãmm) Horizontal pitch: 3 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6-FR PBT-FR Material group: I Housing material: PA 6.6-FR PBT-FR |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Mode of protection: (DC+) - (DC-) (DC+/DC-) - PE Direction of action: (L+)-PE & (L-)-PE & (L+)-(L-) Rated load current IL: 80 A Residual current IPE: ââ°¤ 20 õA DC ââ°¤ 350 õA AC Standby power consumption PC: ââ°¤ 25 mVA Nominal discharge current In (8/20) õs: 15 kA Maximum discharge current Imax (8/20) õs: 40 kA Impulse discharge current (10/350)Ãõs, charge: 2.5 As Impulse discharge current (10/350)Ãõs, specific energy: 6.25 kJ/é Impulse discharge current (10/350)Ãõs, peak value limp: 5 kA Total discharge current Itotal (8/20)Ãõs: 40 kA Total discharge current Itotal (10/350)Ãõs: 5 kA Voltage protection level Up: ââ°¤ 3.5 kV Residual voltage Ures: ââ°¤ 3.5 kV (at In) ââ°¤ 2.9 kV (at 5 kA) ââ°¤ 3.2 kV (at 10 kA) ââ°¤ 3.7 kV (at 20 kA) ââ°¤ 4.1 kV (at 30 kA) ââ°¤ 4.6 kV (at 40 kA) Response time tA: ââ°¤ 25 ns PV protective circuit Connection configuration: Y configuration SPD failure behavior: OCFM (Open-Circuit Failure Mode) Protective circuit DC voltage side (DC) Open circuit voltage UOCSTC: ââ°¤ 975 VÃDC Maximum discharge current Imax (8/20) õs: 40 kA Response time tA: ââ°¤ 25 ns Impulse discharge current (10/350)Ãõs, charge: 2.5 As Impulse discharge current (10/350)Ãõs, specific energy: 6.25 kJ/é Impulse discharge current (10/350)Ãõs, peak value limp: 5 kA Total discharge current Itotal (8/20)Ãõs: 40 kA Total discharge current Itotal (10/350)Ãõs: 5 kA Insulation resistance Riso: > 5 Gé (at 500 V DC) Nominal discharge current In (8/20) õs: 15 kA Rated load current IL: 80 A Continuous operating current ICPV: < 20 õA Maximum continuous operating voltage UCPV: 1170 VÃDC Short-circuit current rating ISCPV: 2000 A Residual voltage Ures: ââ°¤ 3.5 kV (at In) ââ°¤ 2.9 kV (at 5 kA) ââ°¤ 3.2 kV (at 10 kA) ââ°¤ 3.7 kV (at 20 kA) ââ°¤ 4.1 kV (at 30 kA) ââ°¤ 4.6 kV (at 40 kA) Residual current IPE: ââ°¤ 20 õA DC ââ°¤ 350 õA AC Voltage protection level Up: ââ°¤ 3.5 kV Standby power consumption PC: ââ°¤ 25 mVA |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (only when all terminal points are used) Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ââ°¤ 2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 60g (Half-sine / 11 ms / 3x ñX, ñY, ñZ) Vibration (operation): 7.5g (5-500 Hz/2.5 h/XYZ) |
Approvals | UL specifications Maximum continuous operating voltage MCOV: 1170 VÃDC Short-circuit current rating (SCCR): 50 kA Voltage protection rating VPR: 3 kV Nominal discharge current In: 10 kA Mode of protection: (L+) - (L-) (L+) - G (L-) - G Nominal voltage: 1170 VÃDC Power distribution system: DCÃPV SPD Type: 1CA UL indicator/remote signaling Operating voltage: 125 VÃAC AC operating current: 1 A AC UL connection data Tightening torque: 30 lbf-in. Conductor cross section AWG: 14 ... 2 |
Standards and regulations | Standards/specifications: ENÃ61643-31 IEC 61643-31 Note: 2019 2018 |
Mounting | Mounting type: DIN rail: 35 mm |