Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8edf7c18db5b524f8dfb3d5a845f1d7f/-S204x204-FJPG Width: 55 mm Height: 122.4 mm Depth: 36.9 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). Complete module width: 55 mm Complete module height: 124.6 mm Complete module depth: 76.1 mm Note: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). |
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Interfaces | AxiolineFlocal bus Number of interfaces: 2 Connection method: Bus base module Transmission speed: 100 Mbps SmartElement interface Number of interfaces: 6 Connection method: Card edge connector |
Product properties | Type: block modular Product type: I/O component Product family: AxiolineF Mounting position: Wall mounting on horizontal or vertical DIN rail Insulation characteristics Overvoltage category: II (IEC 60664-1, EN60664-1) Pollution degree: 2 (IEC 60664-1, EN60664-1) |
Electrical properties | Potentials: AxiolineF local bus supply (U Supply voltage: 5 VDC Potentials: Communications power supply of the Smart Elements (U Supply voltage: 3.3 VDC (using card edge connectors) Potentials: I/O supply feed-in (U Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 16 A (provide external protection) max. 12 A (Applications with UL approval, external fusing) Current consumption: min. 1.5 mA (without connected SmartElements, with nominal voltage) Power consumption: max. 480 W max. 360 W (Applications with UL approval) Protective circuit: Surge protection; Suppressor diode Electrical isolation/isolation of the voltage ranges Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min. Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: I/O supply feed-in (UP) Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.5 mm² ... 2.5 mm² Conductor cross section flexible: 0.5 mm² ... 2.5 mm² Conductor cross section AWG: 20 ... 14 Stripping length: 8 mm I/O supply feed-in (U Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. Conductor cross section, rigid: 0.5 mm² ... 2.5 mm² Conductor cross section, flexible: 0.5 mm² ... 2.5 mm² Conductor cross section AWG: 20 ... 14 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Mounting | Mounting type: DIN rail mounting Mounting position: Wall mounting on horizontal or vertical DIN rail |
ECLASS | ECLASS-11.0: 27242610 ECLASS-12.0: 27242610 ECLASS-13.0: 27242610 |
ETIM | ETIM 9.0: EC001600 |
UNSPSC | UNSPSC 21.0: 32151600 |