RIF-1-RPT-LDP-12DC/1IC - Relay Module


Notes | General: FBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21) |
Product properties | Product type: Relay Module Product family: RIFLINEÃcomplete Application: high inrush currents Operating mode: 100% operating factor Mechanical service life: 3x 107 cycles Insulation characteristics Insulation: Safe isolation, reinforced insulation Insulation characteristics: Standards/regulations Insulation: Safe isolation, reinforced insulation Overvoltage category: III Pollution degree: 2 |
Electrical properties | Maximum power dissipation for nominal condition: 0.41 W Test voltage (Winding/contact): 4 kV AC (50ÃHz, 1Ãmin., winding/contact) Standards/regulations Rated insulation voltage: 250 VÃAC Rated surge voltage: 6 kV |
Input data | Coil side Nominal input voltage UN: 12 VÃDC Input voltage range: 9.6 VÃDC ... 16.8 VÃDC (20ðC) Input voltage range in reference to UN: see diagram Drive and function: monostable Drive (polarity): polarized Typical input current at UN: 34 mA Typical response time: 8 ms Typical release time: 10 ms Coil voltage: 12 VÃDC Protective circuit: Surge protection; Freewheeling diode Operating voltage display: Yellow LED |
Output data | Switching Contact switching type: 1 N/O contact Type of switch contact: Single contact Contact material: AgSnO Maximum switching voltage: 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) Minimum switching voltage: 12 V (100 mA) Limiting continuous current: 6 A 10 A (Value is permissible if connections 11 and 21, as well as connections 14 and 24 are bridged.) Maximum inrush current: 80 A (20Ãms) 130 A (peak, at capacitive load, 230 V AC, 24 üF) Min. switching current: 100 mA (12ÃVÃDC) Interrupting rating (ohmic load) max.: 264 W (at 24ÃVÃDC, observe contact derating) 58 W (at 48 V DC) 48 W (at 60 V DC) 50 W (at 110 V DC) 80 W (at 220 V DC) 2750 VA (at 250ÃVÃAC, observe contact derating) Switching capacity min.: 1200 mW Utilization category CB Scheme (IEC 60947-5-1): AC15, 6 A/250 V (N/O contact) DC13, 2 A/24 V (N/O contact) |
Connection data | Connection method: Push-in connection Stripping length: 8 mm Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section flexible: 0.14 mm² ... 1.5 mm² 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) Conductor cross section AWG: 26 ... 16 (solid) 26 ... 16 (flexible) |
Dimensions | Drill hole Diameter: 3.2 mm Width: 16 mm Height: 96 mm Depth: 75 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection (Relay): RT II (Relay) Degree of protection (Relay base): IP20 (Relay base) Degree of protection (Installation location): ââ°¥ IP54 (Installation location) Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ââ°¤ 2000 m |
Approvals | Corrosive gas test Identification: ISA-S71.04. G3 Harsh Group ENÃ60068-2-60 |
Standards and regulations | Standards/regulations Standards/regulations: IEC 60947-5-1 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |