Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 76 A, cross section: 6 mm2-25 mm2, connection direction of the conductor to plug-in direction: 0°, width: 12 mm
Cod. Articolo: 3073348
Cod. Fornitore: 3073348
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product properties
Product type: Panel feed-through terminal block Product family: UW 16 Number of positions: 1 Pitch: 12 mm Number of connections: 2 Number of rows: 1 Number of potentials: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Nominal current IN: 76 A Nominal voltage UN: 500 V (without spacer plate) Degree of pollution: 3 Rated voltage (III/3): 500 V Rated surge voltage (III/3): 6 kV
Connection data
Connection technology Connector system: UW 16 / PW 16 Nominal cross section: 16 mm² Conductor connection exterior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 6 mm² ... 25 mm² Conductor cross section flexible: 6 mm² ... 16 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 6 mm² ... 16 mm² 2 conductors with same cross section, solid: 2.5 mm² ... 10 mm² 2 conductors with same cross section, flexible: 2.5 mm² ... 6 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 4 mm² ... 6 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 4 mm² ... 6 mm² Internal cylindrical gage: B7 Stripping length: 16 mm Tightening torque: 2 Nm ... 2.3 Nm Conductor connection interior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 6 mm² ... 25 mm² Conductor cross section flexible: 6 mm² ... 16 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 6 mm² ... 16 mm² 2 conductors with same cross section, solid: 2.5 mm² ... 10 mm² 2 conductors with same cross section, flexible: 2.5 mm² ... 6 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 4 mm² ... 6 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 4 mm² ... 6 mm² Internal cylindrical gage: B7 Stripping length: 16 mm Tightening torque: 2 Nm ... 2.3 Nm
Mounting
Plate thickness: 1 mm ... 6 mm Attachment to feed-through panel Tightening torque: 1 Nm (Mounting screw torque) Screw: M4
Material specifications
Material data - contact Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 Contact material: Cu alloy Surface characteristics: tin-plated Material data - housing Color (Housing): gray (7042) Insulating material: PA Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 Glow wire flammability index GWFI according to EN60695-2-12: 850 Glow wire ignition temperature GWIT according to EN60695-2-13: 775 Temperature for the ball pressure test according to EN60695-10-2: 125°C
Notes
Safety note Safety note: ⢠Only electrically qualified personnel may install and operate the product. To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. ⢠Observe the technical data provided here and refer to the documents listed under âDownloadsâ. The download area contains important information, such as installation notes, technical drawings, and 3D data. ⢠The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
Dimensions
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG Pitch: 12 mm Width [w]: 12 mm External dimensions Width [w]: 12 mm Height [h1]: 41.14 mm Length [l1]: 36.83 mm Internal dimensions Width [w]: 12 mm Height [h2]: 38.31 mm Length [l2]: 29.51 mm
Mechanical tests
Test for conductor damage and slackening Specification: IEC 60947-7-1:2009-04 Result: Test passed Pull-out test Specification: IEC 60947-7-1:2009-04 Conductor cross section/conductor type/tractive force setpoint/actual value: 6 mm² / solid / > 80 N 6 mm² / flexible / > 80 N 25 mm² / stranded / > 135 N 16 mm² / flexible / > 100 N
Electrical tests
Temperature-rise test Specification: IEC 60947-7-1:2009-04 Requirement temperature-rise test: Increase in temperature â¤45K Short-time withstand current Specification: IEC 60947-7-1:2009-04 Air clearances and creepage distances | 1. Insulation coordination Application: without spacer plate Specification: IEC 60947-7-1:2009-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 500 V Rated surge voltage (III/3): 6 kV minimum clearance value - non-homogenous field (III/3): 5.5 mm minimum creepage distance (III/3): 6.3 mm Air clearances and creepage distances | 2. Insulation coordination Application: with spacer plate Specification: IEC 60947-7-1:2009-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 800 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 10 mm
Environmental and real-life conditions
Glow-wire test Specification: IEC 60695-2-11:2000-10 Temperature: 960°C Time of exposure: 30 s Ambient conditions Ambient temperature (operation): -40°C ... 100°C (Depending on the current carrying capacity/derating curve) Ambient temperature (storage/transport): -40°C ... 70°C Relative humidity (storage/transport): 30 % ... 70 % Ambient temperature (assembly): -5°C ... 100°C
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.