Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 150 A, cross section: 16 mm2-50 mm2, connection direction of the conductor to plug-in direction: 0°, width: 18.8 mm
Cod. Articolo: 0708726
Cod. Fornitore: 0708726
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product properties
Product type: Panel feed-through terminal block Product family: HDFK 50 Number of positions: 1 Pitch: 18.8 mm Number of connections: 2 Number of rows: 1 Number of potentials: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Nominal current IN: 150 A Nominal voltage UN: 690 V Degree of pollution: 3 Rated voltage (III/3): 690 V Rated surge voltage (III/3): 8 kV
Connection data
Connection technology Connector system: HDFK 50 Nominal cross section: 50 mm² Conductor connection exterior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 16 mm² ... 50 mm² Conductor cross section flexible: 16 mm² ... 50 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 10 mm² ... 50 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 10 mm² ... 50 mm² 2 conductors with same cross section, solid: 6 mm² ... 16 mm² 2 conductors with same cross section, flexible: 10 mm² ... 16 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 6 mm² ... 10 mm² Internal cylindrical gage: B10 Stripping length: 24 mm Tightening torque: 6 Nm ... 8 Nm Conductor connection interior Connection method: Screw connection with tension sleeve Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 16 mm² ... 50 mm² Conductor cross section flexible: 16 mm² ... 50 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 10 mm² ... 50 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 10 mm² ... 50 mm² 2 conductors with same cross section, solid: 6 mm² ... 16 mm² 2 conductors with same cross section, flexible: 10 mm² ... 16 mm² 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 6 mm² ... 10 mm² Internal cylindrical gage: B10 Stripping length: 24 mm Tightening torque: 6 Nm ... 8 Nm
Mounting
Plate thickness: 1 mm ... 6 mm
Material specifications
Material data - contact Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 Contact material: Cu alloy Surface characteristics: tin-plated Material data - housing Color (Housing): green-yellow () Insulating material: PA Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 Glow wire flammability index GWFI according to EN60695-2-12: 850 Glow wire ignition temperature GWIT according to EN60695-2-13: 775 Temperature for the ball pressure test according to EN60695-10-2: 125°C
Notes
Safety note Safety note: ⢠Only electrically qualified personnel may install and operate the product. To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. ⢠Observe the technical data provided here and refer to the documents listed under âDownloadsâ. The download area contains important information, such as installation notes, technical drawings, and 3D data. ⢠The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. ï· There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE.
Dimensions
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG Pitch: 18.8 mm Width [w]: 18.8 mm Height [h]: 55 mm External dimensions Width [w]: 18.8 mm Height [h1]: 54 mm Length [l1]: 43 mm Internal dimensions Width [w]: 18.8 mm Height [h2]: 55 mm Length [l2]: 35 mm
Electrical tests
Air clearances and creepage distances | 1. Insulation coordination Application: Metal wall 1.0mm...6.0mm Specification: IEC 60947-7-1:2002-07 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 690 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 8 mm Air clearances and creepage distances | 2. Insulation coordination Application: Plastic panel 1.0...6.0mm Specification: IEC 60947-7-1:2002-07 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 630 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 8 mm Air clearances and creepage distances | 3. Insulation coordination Application: Plastic panel 1.0...6.0mm with DP-HDFK spacer plate Specification: IEC 60947-7-1:2002-07 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 1000 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 12.5 mm
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.