Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2903159
PHOENIX CONTACT 2903159
PHOENIX CONTACTNon disponibile

TRIO-PS-2G/1AC/48DC/5 - Power supply unit

Primary-switched TRIO power supply for DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule
Cod. Articolo: 2903159
Cod. Fornitore: 2903159
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Input dataAC operation
Network type: Star network
Nominal input voltage range: 100 VAC ... 240 VAC
Input voltage range: 100 VAC ... 240 VAC -15%...+10%
Electric strength, max.: ≤ 300 VAC 15 s
Typical national grid voltage: 120 VAC
230 VAC
Voltage type of supply voltage: AC/DC
Inrush current integral (I2t): < 0.3 A2s
Inrush current limitation: 15 A (after 1ms)
AC frequency range: 50 Hz ... 60 Hz ±10%
Frequency range (fN): 50 Hz ... 60 Hz ±5Hz
Mains buffering time: typ. 15 ms (120VAC)
typ. 15 ms (230 V AC)
Current consumption: 2.9 A (100VAC)
2.3 A (120VAC)
1.2 A (230 V AC)
1.2 A (240VAC)
Nominal power consumption: 285.7 VA
Power factor (cos phi): 0.91
Input fuse: 6.3 A (internal (device protection))
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE: < 3.5 mA
< 1.7 mA (264VAC, 60Hz)
POWER factor: > 0.9 (120VAC)
> 0.9 (230 V AC)
DC operation
Nominal input voltage range: 110 VDC ... 250 VDC
Input voltage range: 110 VDC ... 250 VDC ±10%
Extended input voltage range in operation: > 88 VDC (Derating <99 V DC: 2%/V)
Derating: < 99 VDC (2 %/V)
Switch-on voltage: 90 VDC
Shut-down voltage: 70 VDC
Voltage type of supply voltage: AC/DC
Mains buffering time: > 20 ms (230 V AC)
Current consumption: 2.5 A (110VDC)
1.1 A (250VDC)
Output dataEfficiency: typ. 90.5 % (120VAC)
typ. 91 % (230 V AC)
Output characteristic: U/I with dynamic load reserve
Nominal output voltage: 48 VDC ±1%
Setting range of the output voltage (USet): 36 VDC ... 55 VDC (> 48VDC, constant capacity restricted)
Nominal output current (IN): 5 A
Dynamic Boost (IDyn.Boost): 7.5 A (5 s)
Derating: > 60°C ... 70°C (2.5%/K)
POWER factor: > 0.9 (120VAC)
> 0.9 (230 V AC)
Feedback voltage resistance: ≤ 60 VDC
Protection against overvoltage at the output (OVP): ≤ 60 VDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 20 mVPP (with nominal values)
Short-circuit-proof: yes
No-load proof: yes
Output power: 240 W
360 W
Peak switching voltages nominal load: < 15 mVPP
Maximum no-load power dissipation: typ. 4 W (120VAC)
typ. 4.1 W (230 V AC)
Power loss nominal load max.: typ. 24.5 W (120VAC)
typ. 20.1 W (230 V AC)
Short-circuit current: < 7 ADC (Permanent)
Rise time: 20 ms (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Signal: DC OK
Continuous load current: 100 mA
Signal relay 13/14
Default: closed
Digital: 30 VAC 30 VDC 100 mA
Connection dataInput
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 10 mm
Output
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 8 mm
Signal
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 1.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 1.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.: 0.2 mm²
Single conductor/terminal point, stranded, with ferrule, max.: 1.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 16
Stripping length: 8 mm
SignalingTypes of signaling: LED
Floating signal contact
Signal output: LED status indicator
Signalization designation: DC OK
Status display: LED
Color: green
DC OK: UOUT > 0.7 x UN (UN = 48VDC)
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 3 kV AC (type test)
1.5 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: TRIO POWER
MTBF (IEC 61709, SN 29500): > 2000000 h (25°C)
> 1200000 h (40°C)
> 620000 h (60°C)
Insulation characteristics
Protection class: I (in closed control cabinet)
Degree of pollution: 2
DimensionsWidth: 42 mm
Height: 130 mm
Depth: 160 mm
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: horizontally 0 mm (≤ 40°C) 10 mm (≤ 70°C), vertically 50 mm
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsFlammability rating according to UL94 (housing / terminal blocks): V0
Housing material: Metal
Type of housing: Aluminum (AlMg3)
Hood version: Polycarbonate
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (start-up type tested): -40°C
Maximum altitude: ≤ 5000 m (>2000m, Derating: 10%/1000m)
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min.
DNVGL CG-0339 / Class B
2 Hz - 100 Hz resonance search, 90 min. in resonance,
2 Hz - 25 Hz, ±1.6 mm amplitude,
25 Hz - 100 Hz, 4g acceleration
Standards and regulationsRail applications: EN50121-4
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: IEC 62368-1(SELV)
Standard – Safety extra-low voltage: IEC 60950-1 (SELV) and EN60204-1 (PELV)
Standard - Safe isolation: DINVDE0100-410
Standard - Safety of power supply units up to 1100 V (insulation distances): DINEN61558-2-16
Overvoltage category
EN 60950-1: II
EN 62477-1: III
ApprovalsUL approvals: UL Listed UL508
UL/C-UL Recognized UL60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Conformity/Approvals
SIL in accordance with IEC 61508: 0
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Conducted noise emission: EN55016
EN61000-6-3 (Class B)
Noise emission: EN 55011 (EN 55022)
EN55016
EN61000-6-3 (Class B)
Harmonic currents
Frequency range: ClassA
Flicker
Frequency range: 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 6 kV (Test Level 4)
Discharge in air: 8 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2 GHz
2 GHz ... 6 GHz
Test field strength: 10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Voltage dips
Standards/regulations: EN61000-4-11
Voltage: 230 VAC
Frequency: 50 Hz
Voltage dip: 70 %
40 %
0 %
Number of periods: 25 periods
10 periods
1 period
Additional text: Test Level 2
Comments: Criterion A
Emitted interference
Standards/regulations: EN61000-6-3
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00040.pdf

Approvals_00041.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Data_sheet_03809.pdf

Manufacturer_declaration_03112.pdf

Manufacturer_declaration_04789.pdf

Manufacturer_declaration_05508.pdf

Manufacturer_declaration_15785.pdf

Package_slip_02451.pdf

Technical_drawing_39717.pdf

Various_00006.pdf