| Features | | Variant | Complete device | | Optical focus | Dynamic focus control | | Sensor | CMOS matrix sensor, grayscale values | | Sensor resolution | 2,048 px x 1,088 px | | Illumination | Integrated | | Illumination color | White, LED, Visible, | | Feedback spot | LED, Visible, green, 525 nm, ± 15 nm | | Alignment aid | Laser, Red, 630 nm ... 680 nm | | LED class | Risk group 1 (IEC 62471:2006-07, EN 62471:2008-09) | | Laser class | 1, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021) | | Lens | C-mount | | Optical format | 1″ | | Focal length | 40 mm | | Aperture | 8 |
| | Reading distance | 500 mm ... 2,500 mm | | Scanning frequency | 70 Hz, With resolution of 2 megapixels | | Code resolution | ≥ 0.12 mm |
|
| Mechanics/electronics | | Connection type | 1 x M12, 17-pin plug (serial, CAN, I/Os, power supply) 2 x M12, 8-pin socket (Ethernet, P1 not yet with function) 1 x M8, 4-pin socket (USB) | | Supply voltage | 24 V DC, ± 20 % | | Power consumption | Typ. 20 W, ± 20 % | | Output current | ≤ 100 mA | | Housing | Aluminum die cast | | Housing color | Light blue (RAL 5012) | | Window material | Glass | | Enclosure rating | IP65 (EN 60529 (1991-10), EN 60529/A2 (2002-02)) | | Protection class | III | | Electrical safety | EN 60950-1 (2011-01) | | Weight | 963 g | | Dimensions (L x W x H) | 142.8 mm x 90 mm x 106.1 mm | | MTBF | 100,000 h |
|
| Performance | | Readable code structures | 1D codes, Stacked, 2D codes | | Bar code types | GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Code 39, Code 128, Codabar, Code 32, Code 93, USPS (Postnet, Planet, USPS4SCB), Australian Post, Dutch KIX Post, Royal Mail, Swedish Post | | 2D code types | Data Matrix ECC200, GS1 Data-Matrix, MaxiCode, QR code | | Stacked code types | PDF417 | | Code qualification | On the basis of ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 18004 | | Internal image storage | 512 MB |
|
| Interfaces | | Ethernet | ✔ , TCP/IP | | Function | Data interface (read result output), Service interface, FTP (image transmission) | | Data transmission rate | 10/100/1,000 Mbit/s |
| | PROFINET | ✔ | | Function | PROFINET Single Port (integrated), PROFINET Dual Port (optional via external connection module CDF600-2) |
| | EtherNet/IP™ | ✔ | | Data transmission rate | 10/100/1,000 Mbit/s |
| | Serial | ✔ , RS-232, RS-422 | | Function | Data interface (read result output), Service interface | | Data transmission rate | 0.3 kBaud ... 115.2 kBaud, AUX: 57.6 kBaud (RS-232) |
| | CAN | ✔ | | Function | SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server) | | Data transmission rate | 20 kbit/s ... 1 Mbit/s |
| | PROFIBUS DP | ✔ | | Type of fieldbus integration | Optional over external fieldbus module CDF600-2 |
| | Digital inputs | 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 parameter memory in CDB650/CDM420) | | Configurable inputs | Encoder input, external trigger | | Digital outputs | 6 (CDB650: “Result 1”, “Result 2”, “Result 3”, “Result 4”, 2 external outputs via CMC600 or CDM420: “Result 1”, “Result 2”, 2 external outputs via CMC600 or cable with open end: “Result 1”, “Result 2”, “Result 3”, “Result 4”) | | Configurable outputs | Good read, External illumination control, free configurable output condition, "device ready" | | Reading pulse | Digital inputs, non-powered, serial interface, Ethernet, CAN, auto pulse, presentation mode | | Optical indicators | 21 LEDs (10 x status display, 10 x LED bar graph, 1 green feedback spot) | | Acoustic indicators | Beeper/buzzer (can be switched off, can be assigned a function to signal a result) | | Control elements | 2 buttons (choose and start/stop functions) | | Operator interfaces | Web server | | Configuration software | SOPAS ET | | Memory card | Micro SD memory card (flash card) max. 16 GB, optional | | Data storage and retrieval | Image and data storage via microSD memory card and external FTP | | Maximum encoder frequency | 1 kHz | | External illumination control | Via digital output (max. 24 V trigger) or external illumination connection |
|
| Ambient data | | Electromagnetic compatibility (EMC) | EN 61000-6-2:2005-08 / EN 61000-6-3 (2007-01) | | Vibration resistance | EN 60068-2-6:2008-02 | | Shock resistance | EN 60068-2-6 | | Ambient operating temperature | 0 °C ... +50 °C | | Storage temperature | –20 °C ... +70 °C | | Permissible relative humidity | 90 %, Non-condensing | | Ambient light immunity | 2,000 lx, on code |
|
| Classifications | | ECLASS 5.0 | 27280103 | | ECLASS 5.1.4 | 27280103 | | ECLASS 6.0 | 27280103 | | ECLASS 6.2 | 27280103 | | ECLASS 7.0 | 27280103 | | ECLASS 8.0 | 27280103 | | ECLASS 8.1 | 27280103 | | ECLASS 9.0 | 27280103 | | ECLASS 10.0 | 27280103 | | ECLASS 11.0 | 27280103 | | ECLASS 12.0 | 27280103 | | ETIM 5.0 | EC002550 | | ETIM 6.0 | EC002550 | | ETIM 7.0 | EC002999 | | ETIM 8.0 | EC002999 | | UNSPSC 16.0901 | 43211701 |
|