Features Does not require a chassis Include ability to direct output device operation during an abnormal condition Include autocalibration of inputs Include 8â¦32 points per module Offer a variety of AC and DC voltages Provide individually configurable channels Offers a smaller form factor for maximized cabinet space Provide integrated serial port Offer direct connection Include contact output modules Provides up to 16 axes of Integrated Motion over EtherNet/IP Offer input filtering Offers support for Integrated Motion over EtherNet/IP⢠for maximized scalability Offer analog, thermocouple, and RTD modules Include I/O packet rate of10,000 pps Provide optical isolation Address reserve, ASCII, Boolean control, and high-speed counter modules available Provides ability to connect with scaled HMI options from the PanelView⢠Plus portfolio to PanelView 800 graphic terminals for simple features Provides flexibility with DIN rail or panel mounting options Offer selectable response to a broken input sensor Includes a built-in RS-232 serial port on every 1769-L3x controller Offers built-in communication ports for EtherNet/IP or ControlNet networks Removes the need for lithium batteries with built-in energy storage Include high speed input modules Provide high accuracy ratings Include on-board scaling Provide dual Ethernet ports for both DLR and linear topologies Integrate with 1769 Compact I/O⢠modules Support single network strategy to EtherNet/IP TCP/CIP connection 96 Prevents incorrect positioning of module with software keying Require a chassis Provides integrated safety and integrated motion in a single controller Allow control migrations with re-use of existing 1769 I/O Offers flexible user memory options Simplify your system architecture with distributed I/O over EtherNet/IP Support seamless bridging with data control and collection over the same network Permit on-line editing, forcing and other standard activities while securely isolating safety functionality (L4xS controllers only) Direct 1769 platform connection to PowerFlex® drives and other devices through Compact I/O⢠to DPI/SCANport⢠and Compact I/O to DSI/Modbus modules Delivers standard, safety and motion control for On-Machine⢠applications Includes up to a 2-GB secure digital (SD) card for fast program save and restore Support SIL 3, PLe integrity (L4xS controllers only) Includes individual point diagnostic status indicators to ease troubleshooting Supports up to 2 axes Kinematics for simple articulated robotics Provides support for Device Level Ring (DLR) network topologies to help increase network resiliency Available with conformal coating Include over-range and under-range detection and indication Offers open socket capability that allows support for Modbus TCP as well as devices such as printers, barcode readers and servers Let you control distributed I/O via EtherNet/IP, ControlNet, or DeviceNet Lets you control distributed I/O via EtherNet/IP, ControlNet, or DeviceNet (select models only) Offer user memory options ranging 2 MB to 3 MB Connects as many as three banks of Compact I/O⢠to a controller; requires use of a communication adapter module and power supply Require SERCOS interface modules for motion Integrates with 1769 Compact I/O⢠modules Includes a 1769-SDN communication interface module for I/O control and remote device configuration over DeviceNet Provides seamless bridging with data control and collection over the same network Ideal for small, to mid-size applications that require low axis motion and I/O point counts Supports integrated safety up to SIL 3, PLe CAT 4
Specifiche
Specifications Sub Brand:CompactLogix Type:Digital Output Special Features:TTL Output Isolation:1200V AC for 2 s or 1697V DC for 2 s, output point to bus, 75V DC working voltage (IEC Class 2 reinforced insulation) Enclosure:None (open-style) Display:Status LEDs Mounting:DIN Rail / Panel mount Height:118mm, 4.65" Width:35mm, 1.38" Depth:87mm, 3.43" Operating Temperature:0...60 °C (32...140 °F) Number Of Channels:16 Output Signal:4.5...5.5V DC, 50 mV peak-to-peak ripple max Removable Terminal Block:1769-RTBN18 (1 per kit) Replacement Door Label:1769-RL1 (2 per kit) Replacement Door:1769-RD (2 per kit) I/O Modules Digital Solid-State Output Modules:16 Point 5 VDC TTL Output Module
Descrizione
Output Module, CompactLogix, DC Digital, 4.5-5.5VDC, TTL Output, 16 Point, 16 Current Sinking (Low True) Point
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.