Suitable for safety functions | Yes |
With optical interface | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for DeviceNet | Yes |
Supporting protocol for other bus systems | No |
Redundancy | No |
IO link master | No |
Supporting protocol for DeviceNet Safety | Yes |
Supporting protocol for EtherNet/IP | No |
Power dissipation | 3.5 W |
Thermal dissipation | 11.9 BTU/h |
Enclosure type rating | None (open-style) |
Number of nodes, max | 64 nodes |
DeviceNet current draw | 60 mA @ 24V DC |
Current draw | 400 mA @ 5.1V DC, 0 mA @ 24V DC |
Wiring category | 1 - On DeviceNet ports, 3 - On USB ports |
Communication rate | 125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max) |
Isolation voltage | 50V (continuous), basic insulation type, DeviceNet network to backplane, Type tested at 853V AC for 60 s, No isolation between USB and backplane, |
Supporting protocol for LON | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for Modbus | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for SUCONET | No |
With potential separation | No |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Radio standard Bluetooth | No |
Radio standard Wi-Fi 802.11 | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
Slot width | 1 |
DeviceNet connector torque | 0.56 Nm |
DeviceNet voltage range | 11...25V DC CL 2/SELV |
DeviceNet port | 1 DeviceNet open-style 5- or 10-pin linear plug |
DeviceNet power | To comply with the CE low voltage directive (LVD), the DeviceNet network must be powered from a source compliant with the safety extra low voltage (SELV) or protected extra low voltage (PELV). To comply with UL restrictions, the DeviceNet network must be |
Surrounding air temperature, max | 60 ðC |
Emissions | CISPR 11: Class A |
Vibration | 2 G @ 10...500 Hz |
ESD immunity | 6 kV contact discharges, 8 kV air discharges |
EFT/B immunity | ñ3 kV at 5 kHz on DeviceNet ports |
Relative humidity | 5...95% noncondensing |
Shock | Operating: 30 G, Non operating: 50 G |
Conducted RF immunity | 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
Surge transient immunity | ñ2 kV line-earth (CM) on ControlNet ports |
Operating temperature | 0 to 60 ðC |
Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
Storage temperature | -40 ðC |
North American temperature code | T4A |
IEC temperature code | T4 |
Module location | Chassis based, any slot |