ROCKWELL AUTOMATION 1756-DNB
ROCKWELL AUTOMATION 1756-DNB
ROCKWELL AUTOMATION 1756-DNB
ROCKWELL AUTOMATION 1756-DNB
ROCKWELL AUTOMATIONDisponibile

DeviceNet Bridge/Scanner Module

DeviceNet Bridge/Scanner Module
Cod. Articolo: 1756-DNB
Cod. Fornitore: 1756-DNB
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Suitable for safety functionsYes
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsNo
RedundancyNo
IO link masterNo
Supporting protocol for DeviceNet SafetyYes
Supporting protocol for EtherNet/IPNo
Power dissipation3.5 W
Thermal dissipation11.9 BTU/h
Enclosure type ratingNone (open-style)
Number of nodes, max64 nodes
DeviceNet current draw60 mA @ 24V DC
Current draw400 mA @ 5.1V DC, 0 mA @ 24V DC
Wiring category1 - On DeviceNet ports, 3 - On USB ports
Communication rate125 Kbps (500 m max), 250 Kbps (250 m max), 500 Kbps (100 m max)
Isolation voltage50V (continuous), basic insulation type, DeviceNet network to backplane, Type tested at 853V AC for 60 s, No isolation between USB and backplane,
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
With potential separationNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
Slot width1
DeviceNet connector torque0.56 Nm
DeviceNet voltage range11...25V DC CL 2/SELV
DeviceNet port1 DeviceNet open-style 5- or 10-pin linear plug
DeviceNet powerTo comply with the CE low voltage directive (LVD), the DeviceNet network must be powered from a source compliant with the safety extra low voltage (SELV) or protected extra low voltage (PELV). To comply with UL restrictions, the DeviceNet network must be
Surrounding air temperature, max60 °C
EmissionsCISPR 11: Class A
Vibration2 G @ 10...500 Hz
ESD immunity6 kV contact discharges, 8 kV air discharges
EFT/B immunity±3 kV at 5 kHz on DeviceNet ports
Relative humidity5...95% noncondensing
ShockOperating: 30 G, Non operating: 50 G
Conducted RF immunity10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity±2 kV line-earth (CM) on ControlNet ports
Operating temperature0 to 60 °C
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Storage temperature-40 °C
North American temperature codeT4A
IEC temperature codeT4
Module locationChassis based, any slot
Specifiche
Specifications
Product Type:Communication Module
Sub Brand:ControlLogix
Type:Communication Module
Special Features:Standard
Mounting:Chassis
Enclosure:None (open-style)
Display:Digital
Operating Temperature:0...60 °C (32...140 °F)
Communication:DeviceNet
Interface:5 Pin Phoenix Connector
Local Programming Port:1 USB
Communication Interface Modules
DeviceNet Communication Interface Modules:DeviceNet Bridge/Scanner Module