Caratteristiche Tecniche
Specifiche
Descrizione
Caratteristiche Tecniche
Input, currentYes
Input, voltageYes
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableYes
Output, currentNo
Output, voltageNo
Output signal configurableNo
Analogue inputs configurableYes
Analogue outputs configurableNo
Type of electric connectionScrew-/spring clamp connection
Output range±10V, 0…20 mA
Terminal block torque specifications1756-TBCH: 0.5 Nm (4.4 lb.in)
Input conversion methodSuccessive approximation
Module keyingElectronic, software configurable
Offset drift50 µV/°C, 1 µV/°C
Output conversion methodR-Ladder DAC, monotonicity with no missing codes
Drive capabilityVoltage: >2000 Ω, Current: 0...750 Ω
Input range±10V, 0...10V, 0...5V, 0...20 mA
Data formatInteger mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category2 - on signal ports
Overvoltage protectionVoltage: 30V DC, input, Current: 8V AC/DC, input, Output: 24V DC
Module errorInput: 0.2% of range, Voltage: 0.2% of range, output, Current: 0.3% of range, output
Gain drift with temperatureVoltage: 25 ppm/°C maximum, input, Current: 35 ppm/°C maximum, input, Voltage: 25 ppm/°C maximum, output, Current: 50 ppm/°C maximum, output
Voltage and current ratingsBackplane: 375 mA @ 5.1V DC, 100 mA @ 24V DC, Analog inputs: -10...+10V, 4...20 mA, Analog outputs: -10...+10V, 4...20 mA
Module scan time300 µs minimum
Thermal dissipationVoltage: 14.66 BTU/hr, Current: 16.02 BTU/hr
Current draw375 mA @ 5.1V, 100 mA @ 24V
Power dissipationVoltage: 4.3 W, Current: 4.7 W
ResolutionInput: Approx 14 bits across ±10.5V DC (21V total), ±10.5V range: 1.3 mV/bit, 14 bit effective, 0...10.5V range: 1.3 mV/bit, 13 bit effective, 0...5.25V range: 1.3 mV/bit, 12 bit effective, Approx 12 bits across 21 mA, 0...21 mA range: 5.25 μA/bit, Output
Wire sizeSingle wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or
Calibrated accuracyInput: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F), Output: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F)
Open circuit detection timeInput: Positive full-scale reading within 1 s, Output: Current output only (output must be set to >0.1 mA)
Suitable for safety functionsNo
Update period for all channels (RPI), min1 ms
Number, output2 high-speed voltage or current
Number, input4 high-speed, submillisecond, differential
Short circuit protectionElectronically current limited to 21 mA or less
Output settling time<2 ms to 95% of final value with resistive loads
Surrounding air temperature, max60 °C
North American temperature codeT4A
Power consumption4.3 W
EmissionsIEC 61000-6-4
ESD immunity6 kV contact discharges, 8 kV air discharges
EFT/B immunity±2 kV at 5 kHz on shielded signal ports
Relative humidity5...95% noncondensing
Conducted RF immunity10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Surge transient immunity±2 kV line-earth (CM) on shielded signal ports
Operating temperature0 °C
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2700...6
Nonoperating temperature-40 °C
RTB keyingUser-defined mechanical
Vibration2 G @ 10...500 Hz
ShockOperating: 30 G, Non operating: 50 G
Slot width1
Calibration intervalInput: 12 months, Output: 12 months
ATEX temperature codeT4
IECEx temperature codeT4
Repeatability±1 least significant bit (LSB)
Input impedanceVoltage: >1 MΩ, Current: 249 Ω
Isolation voltage250V (continuous), Reinforced insulation type, inputs and outputs to backplane, No isolation between individual inputs or outputs
Enclosure type ratingNone (open-style)
Specifiche
Specifications
Product Type:I/O Modules
Sub Brand:ControlLogix
Type:Analog Combo Module
Special Features:Sub-millisecond channel scans, Synchronized sampling across multiple modules
Mounting:Chassis
Enclosure:None (open-style)
Input Signal:+/- 10V, 0-10.5V, 0-5.25V. 0-21mA
Output Signal:+/- 10.4V, 0-21mA
Isolation:None between channels (Single Ended)
Display:Module Health, In Calibration Mode
Operating Temperature:0...60 °C (32...140 °F)
Removable Terminal Block:1756-TBCH or 1756-TBS6H
I/O Modules
Analog Combination Modules (Please select number of Removable terminal Blocks as addded in the list):Fast Analog 4 Cur-Volt In/2 Cur-Volt Out (36 Pin)
Descrizione
Combination Module, Analog, 4 High Speed Current or Voltage Input, 2 HighSpeed Current or Voltage Output, 4 Point