ROCKWELL AUTOMATION 1756-CN2RXT
ROCKWELL AUTOMATION 1756-CN2RXT
ROCKWELL AUTOMATION 1756-CN2RXT
ROCKWELL AUTOMATIONNon disponibile

ControlNet Redundant Interface Module (100 connections), Logix XT

ControlNet Redundant Interface Module (100 connections), Logix XT
Cod. Articolo: 1756-CN2RXT
Cod. Fornitore: 1756-CN2RXT
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsYes
RedundancyYes
IO link masterNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Transmission rate5000 kBps
Logix communication connections128
Power dissipation6.6 W
Thermal dissipation22.9 BTU/h
ControlNet port2 ControlNet BNC
Enclosure type ratingNone (open-style)
Number of nodes, max99 nodes
Current draw1300 mA @ 5.1V DC, 3 mA @ 24V DC
ControlNet cable1786-RG6 quad shield RG6 coaxial cable
Wiring category1 - on ControlNet ports, 3 - on USB port
Connections supported, max131 maximum
Isolation voltage30V (continuous), Basic Insulation Type, ControlNet A/B to Backplane, ControlNet A to ControlNet B, USB to, ControlNet A/B, and USB to Backplane, Type tested at 500V AC for 60 s
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
With potential separationNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
Slot width1
Voltage and current ratings1.3 A @ 5.1V DC
Surrounding air temperature, max70 °C
Storage temperature-40 to 85 °C
EmissionsCISPR 11: Class A
Vibration2 G @ 10...500 Hz
ESD immunity6 kV contact discharges, 8 kV air discharges
EFT/B immunity±3 kV at 5 kHz on ControlNet ports
Relative humidity5...95% noncondensing
ShockOperating: 30 G, Nonoperating: 30g, 1756-CN2RXT/C, Nonoperating: 50g, 1756-CN2RXT/B
Conducted RF immunity10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity±2 kV line-earth (CM) on ControlNet ports
Operating temperature-25 to 70 °C
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
North American temperature codeT4A
IEC temperature codeT4
Weight, approx0.293 kg
Module locationChassis based, any slot