Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

ROCKWELL AUTOMATION 140MG-G8P-D10-KA
ROCKWELL AUTOMATION 140MG-G8P-D10-KA
ROCKWELL AUTOMATIONNon disponibile

140MG - Motor Circuit Protectors, G frame, 35..65 kA at 480V, MCP (magnetic only), Rated Current 100 A, 1 NO/NC AUX, 250V

140MG - Motor Circuit Protectors, G frame, 35..65 kA at 480V, MCP (magnetic only), Rated Current 100 A, 1 NO/NC AUX, 250V
Cod. Articolo: 140MG-G8P-D10-KA
Cod. Fornitore: 140MG-G8P-D10-KA
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Number of poles3
Number of auxiliary contacts as change-over contact1
With integrated under voltage releaseNo
Rated permanent current Iu100 A
Type of control elementToggle
Rated impulse withstand voltage (Uimp)8 kV
Frame size125 A
Magnetic trip currentCam setting I: 1100 A
Hp rating75 Hp @ 575V, 3-phase
Watt loss19.8 W
Insulation voltage (Ui)Rated 800V per IEC
KW rating, max75 kW @ 500V, 3-phase, AC-3
Rated ultimate short-circuit breaking capacity for Type D combination (Icu)65 kA @ 440V AC per IEC 60947-2/GB 14048.2
Electrical life cycle8000 @ 415V AC
Rated service short-circuit breaking capacity for Type D combination (Ics)100% of Icu @ 690V AC per IEC 60947-2/GB 14048.2
Instantaneous trip circuit breaker (magnetic only) SCCR, max65 kA @ 480V AC per NEMA/UL-489/CSA for combination controller rating
Instantaneous trip setting3 to 125 A
Rated ultimate short-circuit breaking capacity (Icu)65 kA @ 220...230V AC per IEC 60947-2/GB 14048.2
Rated service short-circuit breaking capacity (Ics)75% of Icu @ 690V AC per IEC 60947-2/GB 14048.2
Protection typeAdjustable magnetic only (less than 13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Interrupting rating/breaking capacity35...65 kA at 480V
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP20
Weight, approx2.4 lb
Mechanical life operations25000 /h
Factory option1 NO/NC auxiliary, 250V AC/DC
Height130 mm
Device constructionBuilt-in device fixed built-in technique
Width76.2 mm
Depth70 mm
Operating temperature-13 °F
Storage temperature-40 °F
Wire temperature ratingCu 75 °C
Ambient temperature without derating104 °F
Specifiche
Circuit Breaker Data
Bulletin Number:140MG - Motor Circuit Protectors
Protection Type:MCP (magnetic only)
Frame Size:G frame
Rated Operational Current Ie(A):100 A
Manufacturing
Assembly:Factory Assembled
Internal Accessories
Auxiliaries(AX), Alarm (AL), Auxiliary/Alarm Combination(AX/AL), Right Side Mounting:(1)AX
Voltage for Aux Alarm Combination:250V AC/DC