ROCKWELL AUTOMATIONNon disponibile

Molded Case Ckt-Bkr, 1200A N Frame, 65 kA at 480V, ElecLSI - Lg&ShTm, Hgh Inst, 3 Poles, 1200A, 80 Percent MCCB, No Bus Bar Mounting, None, 24…30V AC/DC, Undervoltage release, None

140G - Molded Case Circuit Breaker, N frame, 65 kA Interrupt Rating, LSI (electronic), 3 Poles, Rated Current 1200 A (80% Rated), Undervoltage Release 24V AC/DC
Cod. Articolo: 140G-N6H3-E12-UJ
Cod. Fornitore: 140G-N6H3-E12-UJ
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of poles3
With integrated under voltage releaseYes
Integrated earth fault protectionNo
Complete device with protection unitYes
Rated permanent current Iu1200 A
Type of control elementToggle
Rated impulse withstand voltage (Uimp)8 kV
Frame size1200 A
Current range80% MCCB
Voltage for reverse-fed circuit breaker, max690V AC per IEC
Watt lossElectronic type: 252 W
Insulation voltage (Ui)Rated 1000V per IEC
Protection type—Electronic I (lnstantaneous trip units, 80 % continuous rated)I3 = 1.5...12 x In (OFF, 1800...14400 A)
Protection type—Electronic I (lnstantaneous trip units, 100 % continuous rated)I3 = 1.5...12 x In (OFF, 1800...14400 A)
Electrical life cycle60 ops/hr @ 415V AC
Operating current (In), max980 A @ 70 °C (158 ˚F) per IEC (Molded case switch rated current)
Interrupting rating65 kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Rated ultimate short-circuit breaking capacity (Icu)IEC 60947-2: 70 kA @ 400...415V AC, 50/60 Hz
Rated service short-circuit breaking capacity (Ics)IEC 60947-2: 75% Icu @ 690V AC, 50/60 Hz
Protection type—Electronic S (short time trip units, 100 % continuous rated)I2 = 0.6...10 x In (OFF, 720...12000 A), t2 = [tsec] @ 10 x In = 0.1, 0.25, 0.5, 0.8 sec
Protection type—Electronic L (long time trip units, 80 % continuous rated)I1 = 0.4...1 x In (480...1200 A), t1 = [tsec] @ 6 x I1 = 3, 6, 12, 18 sec
Protection type—Electronic L (long time trip units, 100 % continuous rated)I1 = 0.4...1 x In (480...1200 A), t1 = [tsec] @ 6 x I1 = 3, 6, 12, 18 sec
Protection typeElectronic LSI-long and short time, high instantaneous
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Protection type—Electronic S (short time trip units, 80 % continuous rated)I2 = 0.6...10 x In (OFF, 720...12000 A), t2 = [tsec] @ 10 x In = 0.1, 0.25, 0.5, 0.8 sec
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Degree of protection (IP)IP40
Weight21.39 lb
Mechanical life operations60 /h
Vibration2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Factory optionUnder voltage release, 24...30V AC/DC
Height268 mm
Device constructionBuilt-in device fixed built-in technique
Width210 mm
Depth154 mm
Storage temperature-40 °F
Wire temperature ratingAl or Cu 75 °C
Operational voltage (Ue)90% of voltage rating @ 3000 meter (9840 ft) altitude
Rated uninterrupted current (Iu)98% of current rating @ 3000 meter (9840 ft) altitude
Ambient temperature without derating104 °F