Molded Case Ckt-Bkr, 1200A N Frame, ElecLSI - Lg&ShTm, Hgh Inst, 3 Poles, 1200A, 80 Percent MCCB, No Bus Bar Mounting, NONE, 24V AC/DC, NONE, 2 Aux

140G - Molded Case Circuit Breaker, N frame, 50 kA Interrupt Rating, LSI (electronic), 3 Poles, Rated Current 1200 A (80% Rated), 2 No/NC AUX, 24V
Cod. Articolo: 140G-N5H3-E12-FJ
Cod. Fornitore: 140G-N5H3-E12-FJ
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Number of poles3
Number of auxiliary contacts as change-over contact2
With integrated under voltage releaseNo
Integrated earth fault protectionNo
Complete device with protection unitYes
Rated permanent current Iu1200 A
Type of control elementToggle
Rated impulse withstand voltage (Uimp)8 kV
Frame size1200 A
Current range80% MCCB
Voltage for reverse-fed circuit breaker, max690V AC per IEC
Watt lossElectronic type: 252 W
Insulation voltage (Ui)Rated 1000V per IEC
Protection type—Electronic I (lnstantaneous trip units, 80 % continuous rated)I3 = 1.5...12 x In (OFF, 1800...14400 A)
Protection type—Electronic I (lnstantaneous trip units, 100 % continuous rated)I3 = 1.5...12 x In (OFF, 1800...14400 A)
Electrical life cycle60 ops/hr @ 415V AC
Operating current (In), max980 A @ 70 °C (158 ˚F) per IEC (Molded case switch rated current)
Interrupting rating65 kA @ 240V AC, 50/60 Hz per NEMA, UL, CSA
Rated ultimate short-circuit breaking capacity (Icu)IEC 60947-2: 85 kA @ 220...230V AC, 50/60 Hz
Rated service short-circuit breaking capacity (Ics)IEC 60947-2: 75% Icu (30 kA) @ 525V AC, 50/60 Hz
Protection type—Electronic S (short time trip units, 100 % continuous rated)I2 = 0.6...10 x In (OFF, 720...12000 A), t2 = [tsec] @ 10 x In = 0.1, 0.25, 0.5, 0.8 sec
Protection type—Electronic L (long time trip units, 80 % continuous rated)I1 = 0.4...1 x In (480...1200 A), t1 = [tsec] @ 6 x I1 = 3, 6, 12, 18 sec
Protection type—Electronic L (long time trip units, 100 % continuous rated)I1 = 0.4...1 x In (480...1200 A), t1 = [tsec] @ 6 x I1 = 3, 6, 12, 18 sec
Protection typeElectronic LSI-long and short time, high instantaneous
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Protection type—Electronic S (short time trip units, 80 % continuous rated)I2 = 0.6...10 x In (OFF, 720...12000 A), t2 = [tsec] @ 10 x In = 0.1, 0.25, 0.5, 0.8 sec
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Degree of protection (IP)IP40
Weight21.39 lb
Mechanical life operations60 /h
Vibration2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Factory option2 NO/NC auxiliary, 24V AC/DC
Height268 mm
Device constructionBuilt-in device fixed built-in technique
Width210 mm
Depth154 mm
Storage temperature-40 °F
Wire temperature ratingAl or Cu 75 °C
Operational voltage (Ue)90% of voltage rating @ 3000 meter (9840 ft) altitude
Rated uninterrupted current (Iu)98% of current rating @ 3000 meter (9840 ft) altitude
Ambient temperature without derating104 °F
Specifiche
Circuit Breaker Data
Device Type:140G - Molded Case Circuit Breaker
Number of Poles:3 Poles
Frame Size:N frame
Rated Current(A):1200 A
Protection:LSI (electronic)
Current Range:80% Rated
Manufacturing
Assembly:Factory Assembled
Internal Accessories
Auxiliary and Alarm Contacts:2 NO/NC AUX, 24V