PROSOFT TECHNOLOGY PLX31-EIP-PND
PROSOFT TECHNOLOGYNon disponibile

EtherNet/IP™ to PROFINET IO Device Gateway

Cod. Articolo: PLX31-EIP-PND
Cod. Fornitore: PLX31-EIP-PND
PROSOFT TECHNOLOGY


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Caratteristiche Tecniche
Features and Benefits
Embedded EDS Add-On Profile allows for simplified integration and reduced configuration time for Rockwell Automation PACs.
No ladder programming is required when using I/O connections.
Multiple I/O connections allow you to set different RPIs for status and control data, enabling Ethernet bandwidth optimization.
Communication via an I/O connection provides guaranteed data delivery and enables the PAC to monitor for communication faults.
SD card slot (SD card optional) is used for storing configuration files in the event of a disaster.
ProSoft Discovery Service allows your PC to find the gateway and change its default IP address without being on the same subnet.
Video setup tutorial provided at psft.com/Ap5
Specifiche
Specifications
Number of Class 3 Server Connections:5
Supported PLC Types:PLC2, PLC5, SLC, CLX, CMPLX
Supported Message Types:PCCC and CIP
Number of Class 3 Client Connections:Connected - 2
Number of Class 3 Client Connections:Unconnected - 1
Number of Class 1 I/O Connections:8
Max I/O connection sizeIn/Out:496/496 bytes
Max RPI time:10 ms per connection
CIP Services Supported:0x4C - CIP Data Table Read
CIP Services Supported:0x4D - CIP Data Table Write
Command List:Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.
Command Sets:PLC-2/PLC-3/PLC5 Basic Command Set
Command Sets:PLC5 Binary Command Set
Command Sets:PLC5 ASCII Command Set
Command Sets:SLC500 Command Set
Hardware
Power Supply:24 VDC nominal
Power Supply:10 to 36 VDC allowed
Power Supply:Positive, Negative, GND Terminals
Current Load:24 VDC nominal @ 300 mA
Current Load:10 to 36 VDC @ 610 mA maximum
Operating Temperature:-25°C to 70°C (-13°F to 158°F)
Storage Temperature:-40°C to 80°C (-40°F to 176°F)
Shock:IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
Shock:IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Vibration:IEC 60068-2-6; 5G @ 10 to 150 Hz
Relative Humidity:5% to 95% RH with no condensation
Dimensions (H x W x D):5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm
LED Indicators:Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), ModuleConfiguration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit
Ethernet Port:10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Shipped With Each Unit:2.5 mm screwdriver
Shipped With Each Unit:ProSoft Solutions DVD
Shipped With Each Unit:J180 Power Connector
Shipped With Each Unit:5’ straight-through Ethernet cable
Descrizione
The EtherNet/IP™ to PROFINET® IO Device (slave) gateway offers bi-directional data transfers between EtherNet/IP™ controllers and a PROFINET® IO controller. The EtherNet/IP™ Driver supports I/O connections for guaranteed data delivery or Message instructions to send data to/from the PACs. The gateway supports 1440 bytes of input data and 1440 bytes of output data for larger applications. In addition, the gateway’s multiple I/O connections, allow you to set different RPIs for control data and module diagnostics, enabling you to optimize your Ethernet bandwidth.