Ground terminal, number of connections: 2, number of positions: 1, connection method: PowerTurn connection, Rated cross section: 95 mm2, cross section: 25 mm2-95 mm2, mounting type: 2.3 mm copper DIN rail, color: green-yellow
Cod. Articolo: 3260106
Cod. Fornitore: 3260106
PHOENIX CONTACT
Caratteristiche Tecniche
Caratteristiche Tecniche
Product properties
Product type: Ground terminal block Number of positions: 1 Area of application: Railway industry Machine building Plant engineering Number of connections: 2 Number of rows: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Rated surge voltage: 8 kV Maximum power dissipation for nominal condition: 7.54 W
Connection data
Grounding foot: Yes Number of connections per level: 2 Nominal cross section: 95 mm² Note: May only be mounted on 2.3 mm copper DIN rails Stripping length: 40 mm Connection in acc. with standard: IEC 60947-7-2 Conductor cross section rigid: 25 mm² ... 95 mm² Cross section AWG: 2 ... 3/0 (converted acc. to IEC) Conductor cross section flexible: 25 mm² ... 95 mm² Conductor cross section, flexible [AWG]: 2 ... 3/0 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 25 mm² ... 95 mm² Flexible conductor cross section (ferrule with plastic sleeve): 25 mm² ... 95 mm² Cross-section with insertion bridge, rigid: 70 mm² Cross-section with insertion bridge, flexible: 70 mm² Connection cross sections directly pluggable Conductor cross section rigid: 25 mm² ... 95 mm² Conductor cross-section flexible (ferrule without plastic sleeve): 25 mm² ... 95 mm² Flexible conductor cross section (ferrule with plastic sleeve): 25 mm² ... 95 mm²
Ex data
Rated data (ATEX/IECEx) Identification: ïII2GDEx eb IIC Gb Operating temperature range: -60°C ... 110°C Ex-certified accessories: 1206612 SZF 3-1,0X5,5 1201662 E/AL-NS 35 output: (Permanent) Ex connection data General Ferrule length: 40 mm Stripping length: 40 mm Nominal cross section: 95 mm² Rated cross section AWG: 4/0 Connection capacity rigid: 25 mm² ... 95 mm² Connection capacity AWG: 4 ... 4/0 Conductor cross section flexible, with ferrule without plastic sleeve min.: 25 mm² Conductor cross section flexible, with ferrule without plastic sleeve max.: 95 mm² Single conductor/terminal point, flexible, with ferrule, without plastic sleeve, AWG: 4 ... 4/0
Dimensions
Width: 25 mm Height: 105.5 mm Depth on NS35/15: 108.7 mm
Material specifications
Color: green-yellow Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 125°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Calorimetric heat release NFPA 130 (ASTM E 1354): 27,5 MJ/kg Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed
Mechanical properties
Mechanical data Open side panel: No
Environmental and real-life conditions
Oscillation/broadband noise Specification: DINEN50155 (VDE0115-200):2008-03 Spectrum: Service life test category2, bogie-mounted Frequency: f1 = 5 Hz to f2 = 250 Hz ASD level: 6.12 (m/s²)²/Hz Acceleration: 3.12g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINEN50155 (VDE0115-200):2008-03 Pulse shape: Half-sine Acceleration: 30g Shock duration: 18ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (operation): -60°C ... 110°C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (operation): 20 % ... 90 % Permissible humidity (storage/transport): 30 % ... 70 %
Standards and regulations
Connection in acc. with standard: IEC 60947-7-2
Mounting
Mounting type: 2.3 mm copper DIN rail
Altri prodotti correlati
Di seguito alcuni articoli correlati a quello che stai vedendo
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.