Feed-through terminal block with bolt connection technology, cross section: 0.1 â⬦ 2.5 mm2, AWG: 26 â⬦ 14, width 12.3 mm, color: blue
Cod. Articolo: 3049110
Cod. Fornitore: 3049110
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Notes
General: Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories). Generalâ Note: The rated insulation voltage applies to insulated cable lugs acc. DIN 46237:1970-07 and for uninsulated cable lugs acc. DIN 46234:1980-03 with shrink sleeve. The rated insulation voltage applies to insulated cable lugs acc. DIN 46237:1970-07 and for uninsulated cable lugs acc. DIN 46234:1980-03 with shrink sleeve. When using uninsulated cable lugs with shrink sleeve the min. required air clearances and creepage distances have to be ensured by the enduser. The rated insulation voltage applies to insulated cable lugs acc. to DIN 46237:1970-07 and for uninsulated cable lugs acc. to DIN 46234:1980-03 with path extension.
Product properties
Product type: Bolt connection terminal block Area of application: Railway industry Machine building Plant engineering Process industry Number of connections: 2 Number of rows: 1 Potentials: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Rated surge voltage: 8 kV Maximum power dissipation for nominal condition: 0.77 W
Connection data
Number of connections per level: 2 Nominal cross section: 2.5 mm² 1 level Stripping length: The stripping length depends on the specification provided by the cable lug manufacturer. Connection in acc. with standard: IEC 60947-7-1 Nominal current: 24 A Maximum load current: 24 A (with a 2.5 mm² conductor cross section) Nominal voltage: 1000 V (Rated voltage for open disconnect point 500 V) Nominal cross section: 2.5 mm² Cable lug connection DIN46234:1980-03 Connection in acc. with standard: DIN46234:1980-03 DIN46237:1970-07 Cross section: 0.5 mm² ... 2.5 mm² 1 mm² ... 2.5 mm² Cross section range AWG: 20 ... 14 (converted acc. to IEC) 18 ... 14 (converted acc. to IEC) Hole diameter: 3.2 mm Width: 6 mm Bolt diameter: 3 mm Screw thread: M3 Tightening torque: 0.6 ... 0.8 Nm Identification color of ring cable lugs : red: 1 mm² Identification color of ring cable lugs : blue: 2.5 mm²
Width: 12.3 mm End cover width: 2.2 mm Height: 66 mm Depth on NS35/7,5: 51 mm Depth on NS35/15: 58.5 mm
Material specifications
Color: blue Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed
Electrical tests
Surge voltage test Test voltage setpoint: 9.8 kV Result: Test passed Temperature-rise test Requirement temperature-rise test: Increase in temperature â¤45K Result: Test passed Short-time withstand current 2.5 mm²: 0.3 kA Power-frequency withstand voltage Test voltage setpoint: 2.2 kV Result: Test passed
Mechanical properties
Mechanical data Open side panel: Yes
Mechanical tests
Mechanical strength Result: Test passed Attachment on the carrier DIN rail/fixing support: NS32/NS35 Test force setpoint: 1 N Result: Test passed
Environmental and real-life conditions
Needle-flame test Time of exposure: 30 s Result: Test passed Oscillation/broadband noise Specification: DINEN50155 (VDE0115-200):2008-03 Spectrum: Service life test category1, classB, body mounted Frequency: f1 = 5 Hz to f2 = 150 Hz ASD level: 1.857 (m/s²)²/Hz Acceleration: 0.8g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINEN50155 (VDE0115-200):2008-03 Pulse shape: Half-sine Acceleration: 5g Shock duration: 30ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (storage/transport): 30 % ... 70 %
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.