Motor terminal block, four-level, with PE foot, connection method:spring-cage connection, cross section:0.08 mm2-4 mm2, AWG:28-12, width:5.2 mm, color:gray, mounting type:NS 35/7,5,NS 35/15
Cod. Articolo: 3036055
Cod. Fornitore: 3036055
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product properties
Product type: Motor terminal block Number of connections: 7 Number of rows: 4 Potentials: 4 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Rated surge voltage: 8 kV Maximum power dissipation for nominal condition: 0.77 W
Connection data
Grounding foot: Yes Number of connections per level: 2 Nominal cross section: 2.5 mm² 1st, 2nd, 3rd and 4th level Note: Please observe the current carrying capacity of the DIN rails. Stripping length: 8 mm ... 10 mm Internal cylindrical gage: A3 Connection in acc. with standard: IEC 60947-7-1/IEC 60947-7-2 Conductor cross section rigid: 0.08 mm² ... 4 mm² Cross section AWG: 28 ... 12 (converted acc. to IEC) Conductor cross section flexible: 0.08 mm² ... 2.5 mm² Conductor cross section, flexible [AWG]: 28 ... 14 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.14 mm² ... 2.5 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.14 mm² ... 2.5 mm² Nominal current: 20 A Maximum load current: 26 A (with 4mm² conductor cross section) Nominal voltage: 800 V Nominal cross section: 2.5 mm²
Dimensions
Width: 5.2 mm End cover width: 2.2 mm Height: 98.5 mm Depth on NS35/7,5: 73.5 mm Depth on NS35/15: 81 mm
Material specifications
Color: gray Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed
Electrical tests
Surge voltage test Test voltage setpoint: 9.8 kV Result: Test passed Temperature-rise test Requirement temperature-rise test: Increase in temperature â¤45K Result: Test passed Short-time withstand current 2.5 mm²: 0.3 kA Power-frequency withstand voltage Test voltage setpoint: 2 kV Result: Test passed
Mechanical properties
Mechanical data Open side panel: Yes
Mechanical tests
Mechanical strength Result: Test passed Attachment on the carrier DIN rail/fixing support: NS35 Test force setpoint: 1 N Result: Test passed Test for conductor damage and slackening Rotation speed: 10rpm Revolutions: 135 Conductor cross section/weight: 0.08 mm² / 0.1 kg 2.5 mm² / 0.7 kg 4 mm² / 0.9 kg Result: Test passed
Environmental and real-life conditions
Aging Temperature cycles: 192 Result: Test passed Needle-flame test Time of exposure: 30 s Result: Test passed Oscillation/broadband noise Specification: DINEN50155 (VDE0115-200):2008-03 Spectrum: Service life test category2, bogie-mounted Frequency: f1 = 5 Hz to f2 = 250 Hz ASD level: 6.12 (m/s²)²/Hz Acceleration: 3.12g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINEN50155 (VDE0115-200):2008-03 Pulse shape: Half-sine Acceleration: 30g Shock duration: 18ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (storage/transport): 30 % ... 70 %
Standards and regulations
Connection in acc. with standard: IEC 60947-7-1/IEC 60947-7-2
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.