Electrical properties | Potentials: Supply of analog modules (U Supply voltage: 24 VÃDC (via voltage jumper) Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Current draw: max. 57 mA typ. 47 mA Electrical isolation/isolation of the voltage ranges Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5ÃV supply incoming remote bus / functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply: 500 VÃAC, 50 Hz, 1 min. Test voltage: 5ÃV supply outgoing remote bus, electrically isolated from functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply: 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5ÃV communications power, 24ÃV analog supply, 24ÃV bus terminal module supply, 5ÃV communications power, bus branch terminal electrically isolated from functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24ÃV main supply, 24ÃV segment supply, electrically isolated from the functional ground: 500 VÃAC, 50 Hz, 1 min.
|