PHOENIX CONTACTNon disponibile

QUINT-PS/1AC/24DC/10/CO - Power supply, with protective coating

Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input:1-phase, output: 24 VDC / 10 A
Cod. Articolo: 2320911
Cod. Fornitore: 2320911
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Input dataAC operation
Nominal input voltage range: 100 VÂAC ... 240 VÂAC
110 VÂDC ... 250 VÂDC
Input voltage range: 85 VÂAC ... 264 VÂAC
90 VÂDC ... 410 VÂDC +5Â% (UL 508: ≤ 250 V DC)
Input voltage range AC: 85 VÂAC ... 264 VÂAC
Input voltage range DC: 90 VÂDC ... 410 VÂDC +5Â% (UL 508: ≤ 300 V DC)
Electric strength, max.: 300 VÂAC
Voltage type of supply voltage: AC/DC
Inrush current: < 15 A
Inrush current integral (I2t): < 1.5 A2s
AC frequency range: 50 Hz ... 60 Hz
Mains buffering time: typ. 36 ms (120ÂVÂAC)
typ. 36 ms (230 V AC)
Current consumption: 4 A (100ÂVÂAC)
1.7 A (240ÂVÂAC)
2.2 A (120ÂVÂAC)
1.3 A (230 V AC)
2.5 A (110ÂVÂDC)
1.2 A (220 VÂDC)
3.4 A (110ÂVÂDC)
1.5 A (250ÂVÂDC)
Nominal power consumption: 303 VA
Protective circuit: Transient surge protection; Varistor, gas-filled surge arrester
Typical response time: < 0.15 s
Input fuse: 10 A (slow-blow, internal)
Permissible backup fuse: B10 B16
Recommended breaker for input protection: 10 A ... 20 A (AC: Characteristics B, C, D, K)
Discharge current to PE: < 3.5 mA
Output dataEfficiency: typ. 92.5 % (230 V AC)
Nominal output voltage: 24 VÂDC ±1Â%
Setting range of the output voltage (USet): 18 VÂDC ... 29.5 VÂDC (> 24ÂVÂDC, constant capacity)
Nominal output current (IN): 10 A (-25°CÂ...Â60°C, UOUT =Â24ÂVÂDC)
POWER BOOST (IBoost): 15 A (-25°CÂ...Â40°C permanent, UOUT = 24ÂVÂDC )
Selective Fuse Breaking (ISFB): 60 A (12Âms)
Magnetic circuit breaker tripping: B2 / B4 / B6 / C2 / C4
Derating: 60°C ... 70°C (2.5%/K)
Feedback voltage resistance: ≤ 35 VÂDC
Protection against overvoltage at the output (OVP): ≤ 32 VÂDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 50 mVPP (with nominal values)
Output power: 240 W
Maximum no-load power dissipation: 9.1 W
Power loss nominal load max.: 22 W
Rise time: < 0.05 s (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Signal: DC OK active
Output description: UOUT > 0.9 x UN: High signal
Switching voltage range: 18 VÂDC ... 24 VÂDC
Maximum inrush current: 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Signal: DC OK floating
Output description: Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage: 30 VÂAC
24 VÂDC
Maximum inrush current: 0.5 A (ATEX/IECEx: Ohmic loads only)
1 A (ATEX/IECEx: Ohmic loads only)
Continuous load current: ≤ 1 A
Signal: POWER BOOST, active
Output description: IOUT < IN: High signal
Switching voltage range: 18 VÂDC ... 24 VÂDC
Output voltage: + 24 VÂDC
Maximum inrush current: 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Signal
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Active switching output
Relay contact
Signal output: DC OK active
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
IOUT < IN: LED ON
LED flashing
Color: green
Signal output: DC OK floating
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
LED flashing
Color: green
Signal output: POWER BOOST, active
Status display: IOUT > IN: LED "BOOST" yellow
Color: yellow
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE: 500 VÂDC (routine test)
Insulation voltage input / PE: 3.5 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: QUINT POWER
MTBF (IEC 61709, SN 29500): > 940000 h (25°C)
> 530000 h (40°C)
> 230000 h (60°C)
Insulation characteristics
Protection class: I
Degree of pollution: 2
DimensionsWidth: 60 mm
Height: 130 mm
Depth: 125 mm
Installation dimensions
Installation distance right/left: 5 mm / 5 mm
Installation distance top/bottom: 50 mm / 50 mm
Alternative assembly
Width: 122 mm
Height: 130 mm
Depth: 63 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: PN ≥50%, 5Âmm horizontally, 15Âmm next to active components, 50Âmm vertically
alignable: PN <50%, 0Âmm horizontally, 40Âmm vertically top, 20 mm vertically bottom
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: yes
Material specificationsHousing material: Metal
Hood version: Galvanized sheet steel, free from chrome (VI)
Side element version: Aluminum
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C (>Â60°C Derating: 2,5Â%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 5000 m
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): 100 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: ENÂ50121-4
ENÂ50121-3-2
HART FSK Physical Layer Test Specification Compliance: Output voltage UOut compliant
Standard âۉ€œ Limitation of mains harmonic currents: ENÂ61000-3-2
Standard - Electrical safety: IEC 61010-2-201Â(SELV)
Explosive atmosphere: ENÂ60079-15 (ZoneÂ2)
Standard - Equipment safety: BG (design tested)
Standard âۉ€œ Safety extra-low voltage: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation: IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1
Noxious gas test: ISA-S71.04-1985 G3 Harsh Group A
Approval - requirement of the semiconductor industry with regard to mains voltage dips: SEMI F47-0706 Compliance Certificate
DeviceNet approval: DeviceNetâ„¢ Power Supply Conformance Tested
Overvoltage category
EN 61010-1: IIÂ(≤Â5000Âm)
EN 62477-1: IIIÂ(≤Â2000Âm)
ApprovalsCSA: CAN/CSA-C22.2 No.Â60950-1-07
CSA-C22.2 No.Â107.1-01
Shipbuilding approval: DNVÂGLÂ(EMCÂB),ÂABS, LR, RINA, NK, BV
SIQ: BG (type approved)
UL approvals: UL/C-UL listed ULÂ508
UL/C-UL Recognized ULÂ60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
DeviceNet approval: DeviceNetâ„¢ Power Supply Conformance Tested
Conformity/Approvals
ATEX: ïÃ‹œÃƒ‚IIÂ3ÂGÂÂExÂecÂnCÂIICÂT4ÂGc
TÜV 11 ATEX 079480 X
INMETRO: DNVÂ19Â0189ÂX
IECEx: ExÂecÂnCÂIICÂT4ÂGc
IECEx TUN 11.0007X
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: ENÂ61000-6-3
ENÂ61000-6-4
EMC requirements for noise immunity: ENÂ61000-6-1
ENÂ61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 55011 (EN 55022)
Electrostatic discharge
Standards/regulations: ENÂ61000-4-2
Electrostatic dischargeâۉ€¹
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: ENÂ61000-4-3
Electromagnetic HF fieldâۉ€¹
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2 GHz
2 GHz ... 3 GHz
Test field strength: 20 V/m (Test Level 3)
10 V/m (Test Level 3)
10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: ENÂ61000-4-4
Fast transients (burst)âۉ€¹
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: ENÂ61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: ENÂ61000-4-6
Conducted interferenceâۉ€¹
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Emitted interference
Standards/regulations: ENÂ61000-6-3
Radio interference voltage in acc. with EN 55011: ENÂ55011 (ENÂ55022) ClassÂB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00041.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00148.pdf

Approvals_00177.pdf

Approvals_00179.pdf

Approvals_00182.pdf

Approvals_00184.pdf

Approvals_00249.pdf

Approvals_01177.pdf

Approvals_01302.pdf

Approvals_01445.pdf

Approvals_01904.pdf

Approvals_01905.pdf

Data_sheet_03126.pdf

Manufacturer_declaration_04622.pdf

Manufacturer_declaration_04623.pdf

Manufacturer_declaration_14322.pdf

Package_slip_02062.pdf

Technical_drawing_37418.pdf

Various_00006.pdf

Various_00080.pdf