PHOENIX CONTACT 2320827
PHOENIX CONTACT 2320827
PHOENIX CONTACTNon disponibile

QUINT-PS/3AC/48DC/20 - Power supply unit

Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input:3-phase, output: 48 VDC / 20 A
Cod. Articolo: 2320827
Cod. Fornitore: 2320827
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Input dataAC operation
Nominal input voltage range: 3x 400 VAC ... 500 VAC
Input voltage range: 3x 400 VAC ... 500 VAC -20%...+15%
Voltage type of supply voltage: AC/DC
Inrush current: < 20 A (typical)
Inrush current integral (I2t): < 1 A2s
Inrush current limitation: 20 A
AC frequency range: 45 Hz ... 65 Hz
Frequency range DC: 0 Hz
Mains buffering time: > 25 ms (400VAC)
> 35 ms (500 VAC)
Current consumption: 3x 2.1 A (400VAC)
3x 1.7 A (500 VAC)
1.7 A (600 VDC)
Nominal power consumption: 1386 VA
Protective circuit: Transient surge protection; Varistor
Typical response time: < 1 s
Permissible backup fuse: B6 B10 B16 AC:
Permissible DC backup fuse: DC: Connect a suitable fuse upstream
Recommended breaker for input protection: 6 A ... 20 A (Characteristic B, C, D, K or comparable)
Discharge current to PE: < 3.5 mA
DC operation
Nominal input voltage range: ± 500 VDC ... 600 VDC
Input voltage range: 500 VDC ... 600 VDC -10%...+34% (mid-point earthed)
Current consumption: 2.2 A (500VDC)
1.9 A (600VDC)
Recommended breaker for input protection: 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Output dataEfficiency: typ. 93 % (400VAC)
Output characteristic: U/I
Nominal output voltage: 48 VDC ±1%
Setting range of the output voltage (USet): 30 VDC ... 56 VDC (> 48VDC, constant capacity restricted)
Nominal output current (IN): 20 A
POWER BOOST (IBoost): 22.5 A (-25°C...40°C permanent, UOUT = 48VDC )
Static Boost (IStat.Boost): 22.5 A
Selective Fuse Breaking (ISFB): 100 A (12ms)
Magnetic circuit breaker tripping: B2 / B4 / B6 / B10 / C2 / C4 / C6
Derating: 60°C ... 70°C (2.5%/K)
Feedback voltage resistance: max. 60 VDC
Protection against overvoltage at the output (OVP): < 60 VDC
Active current limitation: Approx. IBOOST = 22.5 A (for short-circuit)
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 4 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 50 mVPP (with nominal values)
Output power: 960 W
1080 W
Maximum no-load power dissipation: 24 W
Power loss nominal load max.: 70 W
Rise time: < 0.5 ms (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Signal: DC OK active
Output description: UOUT > 0.9 x UN: High signal
Switching voltage range: 18 VDC ... 24 VDC
Maximum inrush current: ≤ 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Signal: DC OK floating
Output description: Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage: 30 V AC/DC
24 VDC
Maximum inrush current: 0.5 A
1 A
Continuous load current: ≤ 1 A
Signal: POWER BOOST, active
Output description: IOUT < IN: High signal
Switching voltage range: 18 VDC ... 24 VDC
Output voltage: + 48 VDC
Maximum inrush current: ≤ 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 6 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 4 mm²
Conductor cross section AWG min.: 18
Conductor cross section AWG max.: 10
Stripping length: 7 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.5 mm²
Conductor cross section, rigid max.: 16 mm²
Conductor cross section flexible min.: 0.5 mm²
Conductor cross section flexible max.: 16 mm²
Conductor cross section AWG min.: 8
Conductor cross section AWG max.: 6
Stripping length: 10 mm
Screw thread: M3
Tightening torque, min: 1.2 Nm
Tightening torque max: 1.5 Nm
Signal
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 6 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 4 mm²
Conductor cross section AWG min.: 18
Conductor cross section AWG max.: 10
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Active switching output
Relay contact
Signal output: DC OK active
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
IOUT < IN: LED ON
Signal output: DC OK floating
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
Signal output: POWER BOOST, active
Status display: IOUT > IN: LED "BOOST" yellow
Electrical propertiesNumber of phases: 3.00
Insulation voltage input/output: 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE: 500 VDC (routine test)
Insulation voltage input / PE: 3.5 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: QUINT POWER
MTBF (IEC 61709, SN 29500): > 890000 h (25°C)
> 509000 h (40°C)
Insulation characteristics
Protection class: I
Degree of pollution: 2
DimensionsWidth: 96 mm
Height: 130 mm
Depth: 179 mm
Installation dimensions
Installation distance right/left: 5 mm / 5 mm
Installation distance top/bottom: 50 mm / 50 mm
Alternative assembly
Width: 176 mm
Height: 130 mm
Depth: 99 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: PN ≥50%, 5mm horizontally, 15mm next to active components, 50mm vertically
alignable: PN <50%, 0mm horizontally, 40mm vertically top, 20 mm vertically bottom
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsHousing material: Metal
Steel sheet, zinc-plated
Type of housing: Steel sheet, zinc-plated
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (start-up type tested): -40°C
Maximum altitude: 5000 m
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: EN50121-4
EN50121-3-2
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: IEC 61010-2-201(SELV)
Standard - Equipment safety: BG (design tested)
Standard - Approval for medical use: IEC 60601-1, 2xMOOP
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178
Standard – Safety extra-low voltage: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation: IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1
Standard - Safety of transformers: IEC 61558-2-17
Overvoltage category
EN 61010-1: II(≤5000m)
EN 62477-1: III(≤2000m)
EN61558-2-16: II(≤4000m)
ApprovalsCSA: CAN/CSA-C22.2 No.60950-1-07
CSA-C22.2 No.107.1-01
UL approvals: UL Listed UL508
UL/C-UL Recognized UL60950-1 (3-wire + PE, star net)
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2 GHz
2 GHz ... 3 GHz
Test field strength: 20 V/m (Test Level 3)
10 V/m (Test Level 3)
10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
6 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00040.pdf

Approvals_00041.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00230.pdf

Manufacturer_declaration_03034.pdf

Manufacturer_declaration_04619.pdf

Manufacturer_declaration_05497.pdf

Manufacturer_declaration_14318.pdf

Package_slip_02084.pdf

Product_information_00152.pdf

Technical_drawing_37413.pdf

Technical_drawing_37414.pdf

Various_00006.pdf

Various_00080.pdf