PHOENIX CONTACTNon disponibile

SACC-BP-FSB-5P-M16/2-900+EMV-N - Device connector rear mounting

Device connector rear mounting, 5-position, coding: B, Rear wall/screw mounting, M16 x 1.5, Bus line, cable length: 2 m, 0.25 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239777
Cod. Articolo: 1444717
Cod. Fornitore: 1444717
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
NotesOrder information:: Lock nut is included in the scope of delivery
Safety note
Safety note: WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
MountingMounting type: Rear wall/screw mounting M16 x 1.5
Product propertiesProduct type: Circular connectors (device side)
Number of positions: 5
Coding: B
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesRated surge voltage: 1.5 kV AC
Nominal voltage UN: 48 V AC
60 V DC
Nominal current IN: 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Connection dataConductor connection
Connection method: Bus line
Cable/lineCable length: 2 m
INTERBUS [900]
Dimensional drawing: https://caas.phoenixcontact.com/caas/v1/stable/media/9190/full/b1500?format=jpg
Cable weight: 70 kg/km
Number of positions: 6
Shielded: yes
Cable type: INTERBUS [900]
Conductor structure: 3 x 2 x 0.22 mm²
Signal speed: 0.66 c
Conductor structure signal line: 32x 0.10 mm
AWG signal line: 24
Conductor cross section: 3x 2x 0.22 mm²
External cable diameter: 8.00 mm
Outer sheath, material: PUR
External sheath, color: may green RAL 6017
Conductor material: Bare Cu litz wires
Material wire insulation: PE
Single wire, color: green-yellow, white-brown, gray-pink
Twisted pairs: 2 cores to the pair
Overall twist: 3 pairs to the core
Insulation resistance: ≥ 5 GΩ*km
Coupling resistance: < 250.00 mΩ/m (at 30 MHz)
Loop resistance: ≤ 159.80 Ω/km
Wave impedance: 120 Ω ±20 % (at 64 kHz)
100 Ω ±15 % (with 1 MHz)
Cable capacity: ≤ 60 nF/km (At 800 Hz)
Nominal voltage, cable: 250 V (Peak value, not for high-power applications)
Test voltage Core/Core: 1500 Vrms
Test voltage Core/Shield: 1000.00 Vrms
Minimum bending radius, fixed installation: 7.5 x D
Minimum bending radius, flexible installation: 15 x D
Smallest bending radius, fixed installation: 60 mm
Smallest bending radius, movable installation: 120 mm
Dynamic load capacity (bending): Max. bending cycles: 5000000, Bending radius: 120 mm, Traversing path: 10 m, Traversing rate: 1.6 m/s, Acceleration: 3.2 m/s²
Near end crosstalk attenuation (NEXT): ≥ 61 dB (at 772 kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2 МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8 МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20 МHz)
Shield attenuation: ≤ 15 dB/km (at 256 kHz)
≤ 24 dB/km (at 772 kHz)
≤ 27 dB/km (with 1 MHz)
≤ 52 dB/km (at 4 МHz)
≤ 84 dB/km (at 10 MHz)
≤ 112 dB/km (at 16 MHz)
≤ 119 dB/km (at 20 МHz)
Flame resistance: according to VDE 0472, Part 4, test type B
according to IEC 60332-1
Ambient temperature (operation): -40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67
Ambient temperature (operation): -25 ... -85
Standards and regulationsStandards/specifications: according to IEC 61076-2-101
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_05485.pdf

Manufacturer_declaration_08788.pdf

Technical_drawing_15714.pdf