PSR-M-B2-XC-SDI8-SDO4-DO4-PI - Safety module

Configurable safety module (basic module), 8safe inputs, 4safe outputs, 4reset inputs or 4signal outputs, 4clock outputs, can be extended via TBUS, up to SIL3, Cat.4/PLe, plug-in Push-in terminal block, TBUS connector not included
Cod. Articolo: 1337849
Cod. Fornitore: 1337849
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety device
Application: Emergency stop
Light grid
Safety door
Safe shutdown
Times
Response time: see user manual
Restart time: min. 5 s (Boot time)
max. 10 s (Boot time)
Electrical propertiesMaximum power dissipation for nominal condition: 7.48 W (with max. permissible load)
Nominal operating mode: 100% operating factor
Interfaces: DIN rail TBUS for connection to the master module, not supplied as standard
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: See section “Insulation coordination”
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 19.2 VDC ... 28.8 VDC
24 VDC -20%/+20% (external fuse, typically 4A)
Rated control supply current IS: typ. 55 mA (Outputs inactive)
Power consumption at US: typ. 1.32 W (Outputs inactive)
Inrush current: 9.16 A (Δt=0.5ms at Us)
Filter time: typ. 5 ms (in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal
Input dataDigital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8
Description of the input: Safety-related digital inputs
NPN
Number of inputs: 8
Input voltage range "0" signal: 0 VDC ... 5 VDC (for safe Off)
Input voltage range "1" signal: 11 VDC ... 28.8 VDC
Input current range "0" signal: < 0.2 mA
Inrush current: max. 524 mA (Δt=6µs at Us)
Filter time: min. 3 ms (adjustable)
max. 250 ms (adjustable)
Test pulse rate ≥2xset filter time, min. Test pulse rate=10ms
max. 3 ms (Test pulse rate ≥10x configured filter time for low test pulse)
max. 250 ms (Test pulse rate ≥10x configured filter time for high test pulse)
Cable length: max. 100 m
Max. permissible overall conductor resistance: max. 1.2 kΩ (Input and reset circuit at US)
Current consumption: typ. 3.7 mA (typically with US)
max. 4.6 mA (at a control voltage of 28.8VDC)
Digital: Reset inputs (FBK)
Description of the input: configurable (as signal output or reset input)
NPN, digital
Number of inputs: 4 (Non-safe inputs)
Input voltage range "0" signal: 0 VDC ... 5 VDC (for safe Off)
Input voltage range "1" signal: 11 VDC ... 28.8 VDC
Input current range "0" signal: < 0.2 mA
Inrush current: max. 906.53 mA (Δt=10µs at Us)
Filter time: 250 ms (constant)
< 250 ms (Test pulse duration)
> 1 s (Test pulse rate)
Cable length: max. 100 m
Max. permissible overall conductor resistance: 1.2 kΩ (Input and reset circuit at US)
Current consumption: typ. 5.7 mA (typically with US)
max. 7 mA (at a control voltage of 28.8VDC)
Output dataDigital: O1,O2,O3,O4
Output description: Safety-related digital outputs
PNP, OSSD, digital
IEC 61131-2 type0.25 (observe limiting continuous current)
Number of outputs: 4
Short-circuit protection: no
Output voltage: < 0.3 V (Low state)
Leakage current: < 500 µA (Low state)
Cable length: max. 100 m
Max. capacitive load: max. 820 nF
Max. inductive load: See "Protective circuit"
Limiting continuous current: 400 mA (per channel)
1.6 A (Total current of all safe digital outputs)
Inrush current: max. 600 mA (Δt=25ms at Us)
Nominal output voltage: 24 VDC (Supply via A1)
Nominal output voltage range: 18.6 VDC ... 28.2 VDC (US-0,7V)
Switching frequency: max. 1/4xtCycle [Hz]
Test pulses: < 235 µs (Test pulse width of low test pulses)
≥ 650 ms (Test pulse rate for low test pulse)
< 150 µs (Test pulse width, high test pulse)
≥ 1.5 s (Test pulse rate, high test pulse)
Discharging circuit: Yes, internal
Signal: MO1, MO2, MO3, MO4
Output description: PNP, digital, IEC 61131-2 type0.1
non-safety-related, configurable (as signal output or reset input)
Number of outputs: 4
Output voltage when switched off: max. 0.1 V
Voltage: 24 VDC (via A1)
Maximum inrush current: 1.1 A (Δt=3sat Us)
Limiting continuous current: 100 mA (per channel)
400 mA (Total current of all digital signal outputs)
Leakage current: max. 4.5 mA (Low state)
Switching frequency: max. 1/4xtCycle [Hz]
Short-circuit protection: Yes (self-limitation at 1.1A)
Cable length: max. 100 m
Clock: T1, T2, T3, T4
Output description: PNP, digital, IEC 61131-2 type0.1
Number of outputs: 4
Voltage: 24 VDC (via A1)
Maximum inrush current: 1.1 A (Δt=3sat Us)
Limiting continuous current: 100 mA (per channel)
400 mA (Total current of all outputs)
Test pulses: ≤ 200 µs (Test pulse duration)
Test pulse rate=8xtCycle [ms]
Short-circuit protection: Yes (self-limitation at 1.1A)
Cable length: max. 100 m
Max. capacitive load: max. 470 nF
Max. inductive load: max. 2.4 mH
Discharging circuit: Yes, internal
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 16
Stripping length: 10 mm
InterfacesData: Service interface
Connection method: USB 2.0 Hi-Speed
Number of connections: 1
Data: Local bus
Note: via the PSR-TBUS DIN rail connector
SignalingStatus display: 1 x LED (green), 1 x LED (orange), 1 x LED (blue)
4 x LED (green, yellow, red)
12 x LED (yellow)
Operating voltage display: 1 x green LED
Error indication: 2xLED (red)
DimensionsWidth: 22.61 mm
Height: 107.74 mm
Depth: 113.6 mm
Material specificationsHousing material: Polyamide PA non-reinforced
CharacteristicsSafety data: ENISO13849
Performance level (PL): e (2-channel wiring)
d (1-channel wiring)
Safety data: IEC 61508 - High-demand for 2-channel wiring
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - High-demand for 1-channel wiring
Safety Integrity Level (SIL): 2
Safety data
Safety Integrity Level (SIL): 2
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (2-channel wiring)
2 (1-channel wiring)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -10°C ... 70°C (observe derating)
Ambient temperature (storage/transport): -20°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 95 % (non-condensing)
Max. permissible relative humidity (operation): 95 % (non-condensing)
Shock: 10g for Δt=16ms (continuous shock, 1000 shocks in each space direction)
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsCE
Identification: CE-compliant
Environmental simulation test
Identification: ISA-S71.04
Note: G3
DNV
Identification: C, EMC2
Certificate: XXX
MountingMounting type: DIN rail mounting
Assembly instructions: Observe derating
Mounting position: vertical or horizontal
Connection method: Push-in connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00042.pdf

Approvals_00043.pdf

Approvals_01697.pdf

Certification_00224.pdf

Certification_00318.pdf

Certification_00353.pdf

Data_sheet_01117.pdf

Manual_00057.pdf

Manual_00058.pdf

Manufacturer_declaration_03997.pdf

Manufacturer_declaration_03998.pdf

Package_slip_01937.pdf

Technical_drawing_11386.pdf