Combination of relay interface and electronic fuse protection on overall width: 6.2 mm, individual configuration of the nominal current (1 A ... 6 A), adjustable output characteristic, active signal output, easy system integration, with screw connection
Cod. Articolo: 1328357
Cod. Fornitore: 1328357
PHOENIX CONTACT
Caratteristiche Tecniche
Descrizione
Caratteristiche Tecniche
Notes
Notes on operation: Repeated hard short circuits can reduce the melting integral of the integrated backup fuse. A suitable flyback diode must be used when switching inductive loads If the DIP switches are not covered by an adjacent module, the PLC-ATP partition plate must be used for ESD protection The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-2. The PLC-ATP separating plate should be installed for safe isolation between adjacent modules Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. At least one functional insulation against adjacent modules is complied with in the support rail direction. If the application has higher requirements on the insulation (basic or reinforced insulation), then these must be realized through suitable measures (e. g., partition plates). Do not use to separate SELV / PELV circuits from other circuits, because safe isolation is not guaranteed.
Product properties
Product type: Relay Module Product family: PLC-INTERFACE Application: with integrated electronic circuit breaker Operating mode: 100% operating factor Data management status Article revision: 02 Insulation characteristics: Air clearances and creepage distances Insulation: Functional insulation Overvoltage category: I Pollution degree: 2
Electrical properties
Maximum power dissipation for nominal condition: < 1.6 W Fuse: electronic
Input data
Operating voltage (UN): 24 V DC (UIn+ - UA2) Operating voltage range (DC): 19.2 V DC ... 30 V DC (UIn+ - UA2) Current consumption (In+): 12 mA Tripping current (IN): 1 A (adjustable) 2 A (adjustable) 3 A (adjustable) 4 A (adjustable) 5 A (adjustable) 6 A (preset) Measuring tolerance: ñ 15 % Power dissipation: 0.06 W (Without load, A1 low) 0.4 W (Without load, A1 high) < 1.6 W (Normal operation) Switching: Switching input A1 Nominal switch-on voltage: 24 V (UA1 - UA2) Switch-on voltage range: 11 V ... 30 V (UA1 - UA2) Switch-off voltage range: 0 V ... 2 V (UA1 - UA2) Current consumption (IA1): 4 mA (24 V) Switch-on time: 36 ms Switch-off time: 10 ms Switching frequency: ââ°¤ 2.5 Hz
Output data
Load circuit: Power MOSFET switching output (positive switching) Voltage drop: 0.16 V (6 A, UIn+ - Uout) Short-circuit switching capacity: 100 A DC 300 A DC (<5 short circuits) Required backup fuse: Only required if Imax of power supply unit > short-circuit switching capacity. Integrated failsafe element Fail-safe element: 15 A Surge voltage protection: > 33 V Max. capacitive load: 12000 õF (Depending on the current setting and the short-circuit current available) Shutdown time (): ââ°¤ 15 ms (Short circuit ââ°¥3 x IN) 0.1 s (Short circuit 2 ... <3 x IN) 1 s (Short circuit 1.5 ... <2 x IN) 4 s (Short circuit 1.1 ... <1.5 x IN) Undervoltage switch-off: ââ°¤ 17.8 V (active) ââ°¥ 19 V (inactive) Overvoltage switch-off: ââ°¥ 30.5 V (active) ââ°¤ 29.5 V (inactive) Waiting time: 5 s (Between the pulses) Number: 5 (Start attempts in hiccup mode) Signal: Feedback contact Output voltage: UIn+ - 0.7 V (high level) Current (Maximum current): ââ°¤ 20 mA State condition (Normal operation): low State condition (Error): high (Fuse has blown) State condition (Hiccup mode): high (After all 5 start attempts have been completed)
Connection data
Connection method: Screw connection Stripping length: 8 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross-section rigid (2 conductors with same cross section): 0.14 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 2.5 mm² 0.14 mm² ... 1.5 mm² Conductor cross section flexible (2 conductors with same cross section): 0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve) Conductor cross section AWG: 30 ... 12 Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
Dimensions
Item dimensions Width: 6.2 mm Height: 80 mm Depth: 94 mm
Environmental and real-life conditions
Ambient conditions Degree of protection: IP20 Degree of protection (Installation location): ââ°¥ IP54 Ambient temperature (operation): -25 °C ... 55 °C (Observe derating in the connected state) Ambient temperature (storage/transport): -40 °C ... 70 °C Altitude: ââ°¤ 2000 m (Without derating) ââ°¤ 3000 m (With correction factor for ambient temperature (operation) x 0.88) Permissible humidity (operation): 95 %
Approvals
UL, USA/Canada Identification: UL 2367 UL 60947-1 UL 60947-5-1 CSA C22.2 No. 60947-1 CSA C22.2 No. 60947-5-1 UL data Operating mode: Indoor use
Standards and regulations
Electromagnetic compatibility (EMC) Standards/regulations: EN 61000-6-2 EN 61000-6-3 Air clearances and creepage distances Standards/regulations: IEC 60664
Mounting
Mounting type: DIN rail mounting Assembly note: in rows with zero spacing Mounting position: any
Descrizione
PLC-RSC- 24DC/1/CB1-6 Interruttore protez.
Altri prodotti correlati
Di seguito alcuni articoli correlati a quello che stai vedendo
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.