Feed-through terminal block, nom. voltage: 1000 V, nominal current: 57 A, number of connections: 2, connection method: Push-in connection, Rated cross section: 10 mm2, cross section: 0.5 mm2 - 16 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
Cod. Articolo: 1322453
Cod. Fornitore: 1322453
PHOENIX CONTACT
Caratteristiche Tecniche
Descrizione
Download
Caratteristiche Tecniche
Product properties
Product type: Feed-through terminal block Area of application: Railway industry Machine building Plant engineering Number of connections: 2 Number of rows: 1 Potentials: 1 Data management status Article revision: 02 Insulation characteristics Overvoltage category: III Degree of pollution: 3
Electrical properties
Rated surge voltage: 8 kV Maximum power dissipation for nominal condition: 1.82 W
Connection data
Number of connections per level: 2 Nominal cross section: 10 mm² Stripping length: 18 mm ... 20 mm Internal cylindrical gage: A6 Connection in acc. with standard: IEC 60947-7-1 Conductor cross section rigid: 0.5 mm² ... 16 mm² Cross section AWG: 20 ... 6 (converted acc. to IEC) Conductor cross section flexible: 0.5 mm² ... 16 mm² Conductor cross section, flexible [AWG]: 20 ... 6 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 10 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 10 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 1.5 mm² ... 4 mm² Nominal current: 57 A Maximum load current: 70 A (with a 16 mm² conductor cross section, rigid) Nominal voltage: 1000 V Connection cross sections directly pluggable Conductor cross section rigid: 1 mm² ... 16 mm² Conductor cross-section flexible (ferrule without plastic sleeve): 4 mm² ... 10 mm² Flexible conductor cross section (ferrule with plastic sleeve): 2.5 mm² ... 10 mm²
Width: 10.2 mm End cover width: 2.2 mm Height: 67.7 mm Depth: 49.5 mm Depth on NS 35/7,5: 50.5 mm Depth on NS 35/15: 58 mm
Material specifications
Color: black (RAL 9005) Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60 °C Relative insulation material temperature index (Elec., UL 746 B): 130 °C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed
Electrical tests
Surge voltage test Test voltage setpoint: 9.8 kV Result: Test passed Temperature-rise test Requirement temperature-rise test: Increase in temperature ââ°¤ 45 K Result: Test passed Short-time withstand current 10 mm²: 1.2 kA Short-time withstand current 16 mm²: 1.92 kA Power-frequency withstand voltage Test voltage setpoint: 2.2 kV Result: Test passed
Mechanical properties
Mechanical data Open side panel: Yes
Mechanical tests
Mechanical strength Result: Test passed Attachment on the carrier DIN rail/fixing support: NS 35 Test force setpoint: 5 N Result: Test passed Test for conductor damage and slackening Rotation speed: 10 rpm Revolutions: 135 Conductor cross section/weight: 0.5 mm² / 0.3 kg 10 mm² / 2 kg 16 mm² / 2.9 kg Result: Test passed
Environmental and real-life conditions
Service life Insertion/withdrawal cycles: 100 Aging Temperature cycles: 192 Result: Test passed Needle-flame test Time of exposure: 30 s Result: Test passed Oscillation/broadband noise Specification: DIN EN 50155 (VDE 0115-200):2008-03 Spectrum: Service life test category 1, class B, body mounted Frequency: f1 = 5 Hz to f2 = 150 Hz ASD level: 1.857 (m/s²)²/Hz Acceleration: 0.8g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DIN EN 50155 (VDE 0115-200):2008-03 Pulse shape: Half-sine Acceleration: 5g Shock duration: 30 ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (operation): -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) Ambient temperature (storage/transport): -25 °C ... 60 °C (for a short time, no longer than 24 h, -60 °C to +70 °C) Ambient temperature (assembly): -5 °C ... 70 °C Ambient temperature (actuation): -5 °C ... 70 °C Permissible humidity (operation): 20 % ... 90 % Permissible humidity (storage/transport): 30 % ... 70 %
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.