Primary-switched power supply unit TRIO POWER, M12 circular connector, Wall mounting, input: 1-phase, output: 24 V DC / 3.75 A
Cod. Articolo: 1278165
Cod. Fornitore: 1278165
PHOENIX CONTACT
Caratteristiche Tecniche
Descrizione
Caratteristiche Tecniche
Input data
AC operation Supply system configuration: Star network (TN, TT, IT (PE)) Nominal input voltage range: 100 V AC ... 277 V AC Input voltage range: 100 V AC ... 277 V AC -15 % ... +10 % 115 V AC ... 277 V AC ±10 % (UL) Derating: < 100 V AC ... 85 V AC (1 %/V) Switch-on voltage: ⥠80 V AC Shut-down voltage: < 75 V AC Typical national grid voltage: 120 V AC 230 V AC Voltage type of supply voltage: AC/DC Inrush current: ⤠35 A (typical, 277 V AC) 17 A (typical, 120 V AC) Inrush current integral (I2t): < 0.45 A2s AC frequency range: 50 Hz ... 60 Hz ±10 % Frequency range (fN): 50 Hz ... 60 Hz ±10 % Mains buffering time: > 25 ms (120 V AC) > 25 ms (230 V AC) Current consumption: 1 A (100 V AC) 0.4 A (277 V AC) Protective circuit: Transient surge protection; Varistor Power factor (cos phi): > 0.92 Switch-on time: < 0.2 s Input fuse: 4 A (internal (device protection)) Recommended breaker for input protection: 6 A ... 16 A (Characteristic B, C, D, K or comparable) Discharge current to PE: < 0.5 mA DC operation Nominal input voltage range: 110 V DC ... 250 V DC Input voltage range: 110 V DC ... 250 V DC -20 % ... +10 % 120 V DC ... 250 V DC ±10 % (UL) Derating: < 110 V DC ... 88 V DC (1 %/V) Switch-on voltage: ⥠75 V DC Shut-down voltage: < 70 V DC Voltage type of supply voltage: AC/DC Current consumption: 0.88 A (110 V DC) 0.38 A (250 V DC)
Output data
Efficiency: typ. 93 % (120 V AC) typ. 94 % (230 V AC) Nominal output voltage: 24 V DC ±2 % Nominal output current (IN): 3.75 A (Class 2 Output) Derating: > 60 °C ... 70 °C (2.0 %/K) Feedback voltage resistance: ⤠35 V DC Protection against overvoltage at the output (OVP): ⤠35 V DC Control deviation: < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Residual ripple: ⤠10 mVPP Short-circuit-proof: yes No-load proof: yes Output power: 90 W Peak switching voltages nominal load: < 100 mV Maximum no-load power dissipation: < 0.25 W (120 V AC) < 0.28 W (230 V AC) Power loss nominal load max.: < 7.4 W (120 V AC) < 6 W (230 V AC) Rise time: typ. 100 ms (UOUT (10 % ... 90 %)) Connection in parallel: yes, for increasing power and redundancy with diode Connection in series: yes, for increased output voltage Signal: DC OK Continuous load current: 100 mA
Connection data
Input Connection method: M12 circular connector Coding: S Type of locking: M12 screw locking Number of positions: 3 Output Connection method: M12 circular connector Coding: L Type of locking: M12 screw locking Number of positions: 5
Signaling
Types of signaling: LED Status display: 2 x LED (green) Signal output: LED status indicator Signalization designation: AC OK Status display: LED Color: green AC OK: ACIn > 0.76 x ACN (ACN = 100 V AC) Signal output: LED status indicatorâ Signalization designation: DC OK Status display: LED Color: green DC OK: UOUT > 0.9 x UN (UN = 24 V DC)
Electrical properties
Number of phases: 1.00 Insulation voltage input/output: 4 kV AC (type test) 3 kV AC (routine test)
Product properties
Product type: Power supply Product family: TRIO POWER MTBF (IEC 61709, SN 29500): > 1475000 h (25 °C) > 1000000 h (40 °C) > 500000 h (60 °C) Data management status Article revision: 00 Insulation characteristics Protection class: I Pollution degree: 2 (IEC 61010-1)
Dimensions
Item dimensions Width: 100 mm Height: 164 mm Depth: 53 mm Drill hole Diameter: 4.2 mm Installation dimensions Installation distance right/left: 20 mm / 20 mm Installation distance top/bottom: 20 mm / 20 mm
Mounting
Mounting type: Wall mounting Assembly note: Alignable: 20 mm horizontally, 20 mm vertically above, 20 mm vertically below With protective coating: no
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks): V0 Housing material: Metal Type of housing: Aluminum (AlMg3)
Environmental and real-life conditions
Ambient conditions Degree of protection: IP67 Ambient temperature (operation): -25 °C ... 70 °C (Derating > 60 °C: 2 %/K) Ambient temperature (storage/transport): -40 °C ... 85 °C Maximum altitude: ⤠4000 m (> 2000 m, Derating: 10 %/1000 m) Climatic class: 4K26 (EN 60721-3-4) Max. permissible relative humidity (operation): ⤠100 % (at 25 °C, non-condensing) Permissible humidity (operation): ⤠100 % (at 25 °C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): 10 Hz ... 59.6 Hz, amplitude ±0.35 mm (in accordance with IEC 60068-2-6) 59.6 Hz ... 150 Hz, 5g, 20 cycles
Standards and regulations
Overvoltage category EN 61010-1: II (⤠4000 m) Overvoltage categoryâ EN 62477-1: III (⤠2000 m) Electrical safety Standard designation: Electrical safety Standards/specifications: IEC 61010-1 Protective extra-low voltage Standard designation: Protective extra-low voltage Standards/specifications: IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Low-voltage power supplies, DC output Standard designation: Low-voltage power supplies, DC output Standards/specifications: EN 61204-3 Safety requirements for electrical equipment for measurement, control, and laboratory use Standard designation: Safety requirements for electrical equipment for measurement, control, and laboratory use Standards/specifications: IEC 61010-1 Limit values for harmonic currents Standard designation: Limit values for harmonic currents Standards/specifications: EN 61000-3-2 Degrees of protection provided by enclosures (IP code) Standard designation: Degrees of protection provided by enclosures (IP code) Standards/specifications: EN/IEC 60529 Mains variation/undervoltage Standard designation: Mains variation/undervoltage Standards/specifications: SEMI F47 - 0706
Approvals
UL Identification: NEC Class 2 according to UL 1310 ULâ Identification: UL/C-UL Listed UL 61010-1 ULââ Identification: UL/C-UL Listed UL 61010-2-201
EMC data
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC Interference emission: Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) Noise immunity: Immunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial) Conducted noise emission: EN 55016 EN 61000-6-3 (Class B) Noise emission: EN 55011 (EN 55022) EN 55016 EN 61000-6-3 (Class B) Harmonic currents Standards/regulations: EN 61000-3-2 EN 61000-3-2 (Class A) Electrostatic discharge Standards/regulations: EN 61000-4-2 Electrostatic dischargeâ Contact discharge: 6 kV (Test Level 3) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN 61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 6 GHz Test field strength: 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: EN 61000-4-4 Fast transients (burst)â Input: 4 kV (Test Level 3 - asymmetrical) Output: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN 61000-4-5 Surge voltage load (surge)â Input: 1 kV (Test Level 1 - symmetrical) 2 kV (Test Level 1 - asymmetrical) Output: 0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical) Comments: Criterion B Conducted interference Standards/regulations: EN 61000-4-6 Conducted interferenceâ Input/Output: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Voltage dips Standards/regulations: EN 61000-4-11 Voltage: 230 V AC Frequency: 50 Hz Voltage dip: 70 % 40 % 0 % Number of periods: 25 periods 10 periods 1 period Comments: Criterion A Criterion B Criterion A Emitted interference Standards/regulations: EN 61000-6-3 Radio interference voltage in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Descrizione
TRIO-PS67/1AC/24DC/3.75/M12 Alimentatore
Altri prodotti correlati
Di seguito alcuni articoli correlati a quello che stai vedendo
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.