Four-channel electronic circuit breaker module for protecting 12 and 24VDC loads against overload and short circuit. Nominal current adjustable from 1A to 4A via LED button. For DIN rail installation via the CAPAROC current rails.
Cod. Articolo: 1115657
Cod. Fornitore: 1115657
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Notes
General Note: LABS release â in accordance with test specification VWPV3.10.7:2005-0 When using CAPAROC E1... modules, for continuous shock in accordance with IEC 60068-2-27 the 6ms/15g degree of severity applies
Product properties
Product type: Device circuit breakers Product family: CAPAROC Number of positions: 1 No. of channels: 4 Number of slots: 2 Insulation characteristics Protection class: III Pollution degree: 2
Electrical properties
No. of channels: 4 General Operating voltage: 10 VDC ... 30 VDC Rated voltage: 12 VDC 24 VDC Rated current IN: 4 ADC (per channel) 1/2/3/4ADC(adjustable per output channel) Rated current (pre-adjusted): 4 A Rated surge voltage: 0.5 kV Tripping method: E (electronic) Feedback resistance: max. 35 VDC Switch-on delay: 50 ms (each channel preset by default) can be adapted with CAPAROC PMIOL and CAPAROC PMPN power modules Required backup fuse: Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element. Short-circuit switching capacity: 300 A Dielectric strength: 35 VDC (Load circuit) Fuse: electronic Efficiency: > 99 % Closed circuit current I0: typ. 20 mA (no load at 24V) Power dissipation: typ. 0.48 W (no load at 24V) < 2.2 W (in nominal operation at 24V and 4A) Waiting time after switch off of a channel: 5 s (at overload / short circuit) Measuring tolerance I: ± 10 % (typ.) Temperature derating: 12 A (Total current at 65°C) 16 A (Total current at55°C) MTBF (IEC 61709, SN 29500): 12874678.91 h (at 25°C with 21% load) 4942154.06 h (at40°C with 34.25%load) 620311.92 h (at 55°C with 100% load) Voltage drop: 0.1 V (at 4 A) Fail-safe element: 5 ADC (per output channel) Load circuit Shutdown time: 4 s (with overload 1.1â¦1.5xIN) 1 s (with overload 1.5â¦2.0xIN) 0.1 s (with overload 2.0â¦3.0xIN) ⤠10 ms (For short circuit > 3.0 x IN) Undervoltage switch-off: ⤠8.5 VDC (active) ⥠9.2 VDC (inactive) Overvoltage switch-off: ⥠32.5 VDC (active) ⤠30.5 VDC (inactive) Max. capacitive load: ⤠20000 µF (Depending on the current setting and the short-circuit current available)
Channel LED off: off (Channel switched off) Channel LED yellow: lit (Channel switched on, channel load>80%) flashing (Programming mode active) two flashes (Check the installation, no communication to power module) Channel LED green: lit (Channel switched on) Channel LED red: lit (Channel switched off, over- or undervoltage active) ON temporarily (Channel switched off, 5s cool-down phase, overload or short-circuit release) flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) two flashes (Channel switched off, system total current limit exceeded) Channel LED red-yellow: flashing (Channel switched on, overload mode, capacity approximately 110...150%,shutdown after 5s) Channel LED red-green: flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release)
Dimensions
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/84ad7270028ea44ea30c9bbb102dae1a/-S204x204-FJPG Width: 12.4 mm Height: 132.4 mm Depth: 111.3 mm (incl. DIN rail 7.5mm)
Material specifications
Material: PA 6 PC Flammability rating according to UL 94: V-0
Environmental and real-life conditions
Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -30°C ... 65°C (The temperature range of the power module must be taken into consideration) Ambient temperature (storage/transport): -40°C ... 70°C Altitude: ⤠4000 m (amsl) Humidity test: 96h, 95%RH, 40°C Shock (operation): 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27) 25g (6ms duration, half-sine shock pulse in accordance with IEC 60068-2-27, continuous shock) Vibration (operation): 5g (10 ... 150Hz / 10cycles / axis / X,Y,Z)
Approvals
UL approval Identification: UL/C-UL Listed UL 508 UL Recognized UL 2367 NEC Class 2 according to UL 1310
Standards and regulations
Standards/specifications: EN61000-6-2 EN61000-6-3 EN60068-2-78 EN50178 EN60068-2-6 EN60068-2-27 Note: EMC â Immunity for industrial areas EMC â Emission for residential, business and commercial properties and small operations Environmental influences â Moisture and heat, constant Equipping power installations with electronic equipment Environmental influences â Vibrations (sinusoidal) Environmental influences â Shocks
Mounting
Mounting type: pluggable onto CAPAROC CR⦠current rail
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.