CBMC EG4 24DC/1-8A NO - Electronic circuit breaker
Multi-channel electronic circuit breaker with electrical isolation for protecting four loads at 24VDC in the event of overload or short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
Cod. Articolo: 1065730
Cod. Fornitore: 1065730
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Notes
General Note: Repeated hard short circuits can reduce the melting integral of the integrated backup fuse.
Product properties
Type: DIN rail module, one-piece Product type: Device circuit breakers Product family: CBMC Number of positions: 1 No. of channels: 4 Insulation characteristics Protection class: III Pollution degree: 2
Electrical properties
No. of channels: 4 General Operating voltage: 18 VDC ... 30 VDC Rated voltage: 24 VDC Rated current IN: max. 32 ADC (IN+) max. 40 ADC (per terminal position when bridging additional devices via IN+) 1/2/3/4/5/6/7/8ADC(adjustable per output channel) Rated current (pre-adjusted): 4 A Rated surge voltage: 0.5 kV Tripping method: EG (electronic - galvanic disconnection) Feedback resistance: max. 35 VDC Required backup fuse: Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element. 30 A (gG, supplied with linear power supply, Icn â¥200A) Short-circuit switching capacity: 300 A Dielectric strength: max. 35 VDC (Load circuit) Fuse: electronic Efficiency: > 99 % Closed circuit current I0: typ. 75 mA Power dissipation: typ. 1.8 W (No-load operation) < 7 W (Nominal operation) Module initialization time: 1.6 s Waiting time after switch off of a channel: 5 s (at overload / short circuit) Measuring tolerance I: ± 15 % Temperature derating: 25 ADC (at 60°C) 28 ADC (at 56°C) 32 ADC (at 52°C) MTBF (IEC 61709, SN 29500): 5000000 h (at 25°C with 21% load) 2000000 h (at40°C with 34.25%load) 321056 h (at52°C with 100%load) Fail-safe element: 15 ADC (per output channel) Load circuit Shutdown time: ⤠10 ms (for short circuit > 2.0 x IN) 1 s (1.2...2.0 x IN) Undervoltage switch-off: ⤠17.8 VDC (active) ⥠18.8 VDC (inactive) Overvoltage switch-off: ⥠30.5 VDC (active) ⤠29.5 VDC (inactive) Max. capacitive load: 45000 µF (Depending on the current setting and the short-circuit current available) Indicator/remote signaling Connection name: Remote indication circuit Switching function: N/O contact Operating voltage: 0 VDC ... 30 VDC Operating current: 100 mA DC
Connection data
Main circuit IN+ Connection method: Push-in connection Stripping length: 15 mm Conductor cross section rigid: 0.2 mm² ... 10 mm² Conductor cross section AWG: 24 ... 8 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 4 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 6 mm² Main circuit IN- Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm² Main circuit OUT Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm² Remote indication circuit Stripping length: 10 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm²
Signaling
Channel LED off: off (Channel switched off) Channel LED yellow: lit (Channel switched on, channel load>80%) flashing (Programming mode active) Channel LED green: lit (Channel switched on) Channel LED red: lit (Channel switched off, relay error, overvoltage or undervoltage active) ON temporarily (Channel switched off, 5s cool-down phase, overload or short-circuit release) flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) two flashes (Channel switched off, device total current limit 32A exceeded)
Dimensions
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/309790686d88b54f8eebbbbce0b13515/-S204x204-FJPG Width: 36 mm Height: 90 mm Depth: 98 mm (incl. DIN rail 7.5mm)
Material specifications
Material: PC PA 6.6 PA 6.3T POM Flammability rating according to UL 94: V-0
Environmental and real-life conditions
Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 60°C Ambient temperature (storage/transport): -40°C ... 70°C Altitude: ⤠3000 m up to52°C (amsl) ⤠4000 m up to46°C (amsl) Humidity test: 96h, 95%RH, 40°C
Standards and regulations
Standards/specifications: EN61000-6-2 EN61000-6-3 EN60068-2-78 EN50178 Note: EMC â Immunity for industrial areas EMC â Emission for residential, business and commercial properties and small operations Environmental influences â Vibrations (sinusoidal) Equipping power installations with electronic equipment
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.