Axioline P, Analog input module, Active analog inputs: 8 (HART), 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20
Cod. Articolo: 1052429
Cod. Fornitore: 1052429
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Dimensions
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/74eb6a06d0a7be42a613b7c139bfe300/-S204x204-FJPG Width: 53.6 mm Height: 126.1 mm Depth: 77.14 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
Notes
Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area Utilization restrictionâ CCCex note: Use in potentially explosive areas is not permitted in China.
Material specifications
Color: traffic grey A RAL 7042
Interfaces
Axioline P local bus Connection method: Bus base module Transmission speed: 100 Mbps
Input data
Analog Input name: Active analog inputs Description of the input: HART enabled, passive analog input signals Number of inputs: 8 (HART) Connection method: Push-in connection Connection technology: 2-conductor Note regarding the connection technology: shielded, twisted pair Current input signal: 4 mA ... 20 mA Protective circuit: Polarity reversal protection of the inputs
Product properties
Type: block modular Product type: I/O component Product family: Axioline P Mounting position: any (no temperature derating) Insulation characteristics Overvoltage category: II Pollution degree: 2
Electrical properties
Potentials: Supply of the logic voltage U Supply voltage range: 19.2 VDC ... 30 VDC (via bus base module (UL) at AXLPBK...) Potentials: Supply of the AxiolineP local bus U Supply voltage: 5 VDC (via bus base module) Current draw: max. 135 mA Potentials: Axioline P extension module supply voltage Supply voltage: UL (via bus base module) Current draw: max. 260 mA (via bus base module) Electrical isolation/isolation of the voltage ranges Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 62 Hz, 1 min. Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 62 Hz, 1 min. Test voltage: Field to functional earth: 500 VAC, 62 Hz, 1 min. Test voltage: Field to 5V and 24V supplies: 1500 VAC, 62 Hz, 1 min.
Connection data
Connection technology Connection name: Axioline P connector Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineP: system and installationâ user manual. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm Axioline P connector Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineP: system and installationâ user manual. Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm
Environmental and real-life conditions
Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 70°C (Standard) Air pressure (operation): 70 kPa ... 106 kPa (up to 2000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 2000m above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulations
Protection class: III (IEC 61140, EN61140, VDE0140-1)
Approvals
ATEX Identification: II 3G Ex ec IIC T4 Gc Certificate: DEMKO 20 ATEX 2334X IECEx Identification: Ex ec IIC T4 Gc Certificate: IECEx UL 20.0002X UKCAEx(UKEX) Identification: II 3G Ex ec IIC T4 Gc Certificate: PxCAI22UKEx1052416X CCCEx Identification: Ex e ib mb [ia Ga] IIC T4 Gb [Ex iaD] Certificate: 2022122310115622 Ex data UL, USA / Canada: Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4
Mounting
Mounting type: DIN rail mounting Mounting position: any (no temperature derating)
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.